Home > Panasonic > Air Conditioner > Panasonic Cs Xc12ckq Cs Xc9ckq Repair Manual

Panasonic Cs Xc12ckq Cs Xc9ckq Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs Xc12ckq Cs Xc9ckq Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 1 Features 2
     2 Functions  
    3
     3 Product Specifications 
    6
     4 Dimensions 
    10
     5 Refrigeration Cycle Diagram 
    12
     6 Block Diagram 
    13
     7 Wiring Diagram  
    14
     8 Operation Details 
    15
     8.1. Indoor Fan Speed Control 
    15
     8.2. Cooling Mode Operation 
    16
     8.3. Soft Dry Mode Operation 
    19
     8.4. Air Circulation Mode Operation 
    21
     8.5. Automatic Mode Operation 
    21
     8.6. Random Auto Restart Control 
    21
     8.7. Vertical Airflow Direction Control 
    22
     8.8. Delay ON Timer Control 
    22
    © 2003 Matsushita Industrial Corp. Sdn. Bhd.
    (11969-T). All rights reserved. Unauthorized copying
    and distribution is a violation of law.
    CS-XC9CKQ CU-XC9CKQ
    CS-XC12CKQ CU-XC12CKQ
     8.9. Remote Control Signal Receiving Sound 22
     8.10. Ionizer Operation 
    23
     8.11. Oxygen Operation Mode 
    27
     9 Operating Instructions 
    31
     10  Installation Instructions 
    39
     10.1. Safety Precautions 
    39
     10.2. INDOOR UNIT 
    42
     10.3. OUTDOOR UNIT 
    45
     11  2-way, 3-way Valve 
    49
     11.1. Air Purging of the Piping and Indoor Unit 
    50
     12  Servicing Information 
    56
     12.1. Indoor Unit 
    56
     12.2. Outdoor Unit 
    58
     13  Troubleshooting Guide 
    63
     13.1. Refrigeration cycle system  
    63
     14  Technical Data 
    65
    Room Air Conditioner
    CONTENTS
     Page  Page
    Order No. MAC0309016C3 
    						
    							 15  Exploded View 67
     16  Replacement Parts List 
    68
     17  Exploded View 
    69
     18  Replacement Parts List 
    70
     19  Electronic Circuit Diagram 
    71
     19.1. REMOTE CONTROL
     
    76
     
        • 
    • •  • 
    High Efficiency
     
        • 
    • •  • 
    Compact Design
     
        • 
    • •  • 
    Comfort Environment
     
        − 
    − −  − 
    Ionizer control for generate negative ion in discharge air
     
        − 
    − −  − 
    Air filter with function to reduce dust and smoke
     
        − 
    − −  − 
    W ider range of horizon tal discharge air
     
        • 
    • •  • 
    Auto Restart
     
        − 
    − −  − 
    Random auto restart after power failure for safety restart
    operation
     
        • 
    • •  • 
    Removable and Washa ble Front Panel
     
        • 
    • •  • 
    Remote Control Self-illuminating Button
     
        • 
    • •  • 
    Catechin Air Purifying Filter
     
        − 
    − −  − 
    Trap dust, tobacco smoke and tiny particles
     
        − 
    − −  − 
    Prevent the growth of bacteria and viruses trapped
     19.2. PRINT PATTERNI NDOOR UNIT PRINTED CIRCUIT
    BOARD
    TOP VIEW 
    77
     19.3. PRINT PATTERNI NDOOR UNIT PRINTED CIRCUIT
    BOARD
    BOTTOMVIEW 
    78
     19.4. PRINT PATTERNI NDICATOR DISPLAY  
    78
     
        • 
    • •  • 
    Quality Improvemen t
     
        − 
    − −  − 
    Gas leakage protection
     
        − 
    − −  − 
    Prevent compressor reversecycle
     
        − 
    − −  − 
    2-stage OLP to protect compressor
     
        − 
    − −  − 
    Noise prevention during soft dry operation
     
        − 
    − −  − 
    Blue Coated Conde nser
     
        − 
    − −  − 
    High resistance to corrosion.
     
        • 
    • •  • 
    Operation Improvement
     
        − 
    − −  − 
    Quiet mode to provide extra quiet operation
     
        − 
    − −  − 
    Oxygen mode to supply oxygen enrich air to indoor
    room.
     
        • 
    • •  • 
    Long Installation Piping
     
        − 
    − −  − 
    XC9CK, long piping up to 10 meter
     
        − 
    − −  − 
    XC12CK , long piping up to 15 meter
     
        • 
    • •  • 
    24-hour Timer Setting
    1 Features
    2
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							2 Functions
    CHECK
    AUTOAU TO
    TEMP
    AUTOAU TOONOFF
    AU TOAU TODRYFA NCOOLCOOL
    FA NFA N
    AUTOAU TO
    RESET CLOCK
    MODE
    FAN SPEED
    OFFCANCEL
    ONSET12
    3
    TIMER
    OFF ON/
    QUIETAIR SWINGAUTOMANUAL
    2
    Remote Control
    Operation OFF / ONOFF / ON  Room Temperature SettingTEMP.
    Operation Mode Selection
    AUTOAutomatic Operation Mode
    COOLCooling Operation Mode
    DRYSoft Dry Operation Mode
    FANAir Circulation Mode
    MODE
    TIME
    Time / Timer Setting
    Hours and minutes setting.
    Clock Setting
    Current time setting.
    Ionizer Operation OFF / ON Indoor Fan Speed Selection
    FAN SPEED
    FAN
     Low Fan Speed
    FAN Medium Fan Speed
    FAN High Fan Speed
    AUTOAutomatic Fan SpeedFAN
    Vertical Airflow Direction Control
    24-hour, OFF / ON Real Timer Setting.
    ON-TIMER
    OFF-TIMER
    Timer Operation Selection
    SET
    CANCEL
    Timer Operation Set / Cancel
    ON Timer and OFF Timer setting and
    cancellation.
    CLOCK AIR SWING
    AUTO
    Automatic Vertical Airflow
    Direction Control
    MANUALVertical Airflow Direction
    Manual Control (5 stages of
    adjustment)
    Oxygen Mode Operation OFF/ON
    Quiet Mode Operation OFF/ON
    QUIET
    Cooling, Soft Dry Operation.
    Temperature Setting (16°C to 30°C)
    Automatic Operation
    Operation with 2°C higher than
    standard temperature.
    Operation with standard temperature.
    Operation with 2°C lower than
    standard 
    temperature.
    Self illuminating
    b
    utton
    2
    3
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Indoor Unit
    Ionizer Control
    Ionizer control for generate negative ion in
    discharge air.
    Indoor Fan Speed Control
    High, Medium and Low.
    Automatic Fan Speed Mode
    _Cooling : Fan rotates at Hi, Me and SLo
    speed. Deodorizing control is
    available.
    _Soft Dry : Fan rotates at Lo- speed.
    Deodorizing control is
    available.
    Automatic air swing and manual adjusted
    by remote control for vertical airflow.
    Manually adjusted by hand for horizontal
    airflow.
    Airflow Direction Control
    Automatic Operation Button
    Press for < 5s to operate Automatic
    operation mode.
    (Used when the remote control cannot be used.)
    Press continuously for 5s or < 10s  to
    operate Test Run/Pump down. Beep
    sound will be heard at the 5th second.
    (Used when test running or servicing.)
    Press continuously for 10s or < 15s  to
    omit or resume the remote control signal
    receiving sound. Beep, beep sound will
    be heard at the 10th second.
    AUTO
    OFF / ON
    Operation Indication Lamps (LED)
    POWER(Green)......... Lights up in operation,
    blinks in Automatic
    Operation Mode judging.
    Operation Mode
    Cooling, Soft Dry, Air Circulation and
    Automatic Mode.
    Oxygen Operation
    To supply oxygen enrich air.Time Delay Safety Control
    Restarting is inhibited for appro. 3
    minutes.
    Starting Current Control
    Quiet Operation
    To provide quiet operation.7 Minutes Time Save Control
    Cooling Operation only.
    Indoor fan motor is delayed for 1.6 seconds
    when indoor, outdoor fan motor and 
    compressor starts simultaneously.
    Random Auto Restart Control
    Operation is restarted randomly after power
    failure at previous setting mode.
    Anti-Freezing Control
    Anti-Freezing control for indoor heat
    exchanger. (Cooling and Soft Dry)
    Press continuously for 15s and above to
    testify oxygen operation. Beep, beep, beep
    sound will be heard at the 15th second.
    QUIET (Orange)......... Lights up in Quiet Mode
    Operation.
    TIMER (Orange)......... Lights up in Timer
    Setting.
    (Green)... .... Lights up in Oxygen
    Mode Operation.
     ION (Green)............ Lights up in Ionizer
    Mode Operation.
    4
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Outdoor Unit
    • To protect compressor from reverse
    rotation when there is a instantaneous
    power failure.
    60 Secs. Forced Operation Control
    • Once the compressor is activated, it
    does not stop within the first 60 secs.
    However, it stops immediately with
    remote control stop signal.
    Overload Protector
    • 2-Stage OLP to protect the compressor.
    Overload Protector will trip when
    – Temperature of compressor increases
    to 120°C.
    – High temperature or high current flows
    to compressor.
    (Refer circuit diagram for OLP
    characteristic)
    Compressor Reverse Rotation
    Protection Control
    Outdoor Fan Operation Control
    • Temperature Fuse.
    5
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							3 Product Specifications
    UnitCS-XC9CKQCU-XC9CKQ
    Power SourcePhase, Voltage, CycleSingle, 230, 60 Hz
    Cooling CapacitykW (BTU/h)2.76 (9,420)
    Moisture Removall/h (Pint/h)1.6 (3.4)
    Airflow MethodOUTLET
    INTAKE
    SIDE VIEWTOP VIEW
    Air VolumeIndoor Air (Lo)m3/min (cfm)6.8 (240)—
    Indoor Air (Me)m3/min (cfm)8.0 (280)—
    Indoor Air (Hi)m3/min (cfm)9.9 (350)32.6 (1,150)
    Indoor Air (SHi)m3/min (cfm)10.9 (380)—
    Noise LeveldB (A)High 36, Low 26High 49
    Power level dBHigh 49High 64
    Electrical DataInput PowerW790
    Running CurrentA3.7
    EERW/W (BTU/hW)3.49 (11.8)
    Starting CurrentA23.0
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 3/8”
    L ; Half Union 1/4”G ; 3-way valve 3/8”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 3/8”
    L ; (liquid side) 1/4”G ; (gas side) 3/8”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power CordLengthm1.9—
    Number of core-wire3 (1.5 mm2)—
    DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)9 -9/32 (236)11 - 3/8 (289)
    Net Weightlb (kg)22 (10.0)68 (31.0)
    CompressorType—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—600
    Air CirculationTypeCross-flow FanPropeller Fan
    MaterialAS + Glass Fiber 20%PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW42.072.4
    RatedOutputW1530
    Fan SpeedLowrpm780—
    Mediumrpm920—
    Highrpm1,140835
    SuperHighrpm1,250—
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinLouver Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×151×20
    FPI1917
    Size (W × H × L)mm610 × 315 × 25.4841 × 508 × 22
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—SUNISO 4GDID or ATMOS
    M60 (290)
    Refrigerant (R-22)g (oz)—890 (31.4)
    Thermosta tElectronic Control—
    Protection Device—2 Stage Overload Protector
    6
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Note:
    UnitCS-XC9CKQCU-XC9CKQ
    Capillary TubeLengthmm—720
    Flow Ratel/min—11.0
    Inner Diametermm—1.5
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—15 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
     
        • 
    • •  • 
    Specifications are subject to change without notice for further improvement.
    7
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							UnitCS-XC12CKQCU-XC12CKQ
    Power SourcePhase, Voltage, CycleSingle, 230, 60 Hz
    Cooling CapacitykW (BTU/h)3.58 (12,220)
    Moisture Removall/h (Pint/h)2.1 (4.4)
    Airflow MethodOUTLET
    INTAKE
    SIDE VIEWTOP VIEW
    Air VolumeIndoor Air (Lo)m3/min (cfm)7.3 (260)—
    Indoor Air (Me)m3/min (cfm)8.7 (310)—
    Indoor Air (Hi)m3/min (cfm)10.2 (360)32.6 (1,150)
    Indoor Air (SHi)m3/min (cfm)10.5 (370)—
    Noise LeveldB (A)High 39, Low 29High 49
    Power level dBHigh 52High 64
    Electrical DataInput PowerkW1.12
    Running CurrentA5.1
    EERW/W (BTU/hW)3.20 (10.9)
    Starting CurrentA33.0
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 1/2”
    L ; Half Union 1/4”G ; 3-way valve 1/2”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 1/2”
    L ; (liquid side) 1/4”G ; (gas side) 1/2”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power CordLengthm1.9—
    Number of core-wire3 (1.5 mm2)—
    DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)9 - 9/32 (236)11 - 3/8 (289)
    Net Weightlb (kg)22 (10.0)79 (36.0)
    CompressorTypeRotary (1 cylinder) rolling piston
    type
    MotorTypeInduction (2-poles)
    RatedOutputkW—0.85
    Air CirculationTypeCross-flow FanPropeller Fan
    MaterialAS + Glass Fiber 20%PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW42.072.4
    RatedOutputW1530
    Fan SpeedLowrpm900—
    Mediumrpm1,080—
    Highrpm1,260835
    SuperHighrpm1,300—
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinLouver Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×151×20
    FPI2117
    Size (W × H × L)mm610 × 315 × 25.4841× 508 × 22
    Refrigerant Control Device—Capilary Tube
    Refrigeration Oil(cm3)—SUNISO 4GDID or
    ATMOS (350)
    Refrigerant (R-22)g (oz)—780 (27.5)
    Thermosta tElectronic Control—
    Protection Device—2 Stage Overload Protector
    Capillary TubeLengthmm—490
    Flow Ratel/min—18.0
    Inner Diametermm—1.7
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    8
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Note:
    UnitCS-XC12CKQCU-XC12CKQ
    Compressor CapacitorµF, VAC—30 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
     
        • 
    • •  • 
    Specifications are subject to change without notice for further improvement.
    9
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							4 Dimensions
    10
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    All Panasonic manuals Comments (0)