1 Features 2 2 Functions 3 3 Product Specifications 6 4 Dimensions 10 5 Refrigeration Cycle Diagram 12 6 Block Diagram 13 7 Wiring Diagram 14 8 Operation Details 15 8.1. Indoor Fan Speed Control 15 8.2. Cooling Mode Operation 16 8.3. Soft Dry Mode Operation 19 8.4. Air Circulation Mode Operation 21 8.5. Automatic Mode Operation 21 8.6. Random Auto Restart Control 21 8.7. Vertical Airflow Direction Control 22 8.8. Delay ON Timer Control 22 © 2003 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-XC9CKQ CU-XC9CKQ CS-XC12CKQ CU-XC12CKQ 8.9. Remote Control Signal Receiving Sound 22 8.10. Ionizer Operation 23 8.11. Oxygen Operation Mode 27 9 Operating Instructions 31 10 Installation Instructions 39 10.1. Safety Precautions 39 10.2. INDOOR UNIT 42 10.3. OUTDOOR UNIT 45 11 2-way, 3-way Valve 49 11.1. Air Purging of the Piping and Indoor Unit 50 12 Servicing Information 56 12.1. Indoor Unit 56 12.2. Outdoor Unit 58 13 Troubleshooting Guide 63 13.1. Refrigeration cycle system 63 14 Technical Data 65 Room Air Conditioner CONTENTS Page Page Order No. MAC0309016C3
15 Exploded View 67 16 Replacement Parts List 68 17 Exploded View 69 18 Replacement Parts List 70 19 Electronic Circuit Diagram 71 19.1. REMOTE CONTROL 76 • • • • High Efficiency • • • • Compact Design • • • • Comfort Environment − − − − Ionizer control for generate negative ion in discharge air − − − − Air filter with function to reduce dust and smoke − − − − W ider range of horizon tal discharge air • • • • Auto Restart − − − − Random auto restart after power failure for safety restart operation • • • • Removable and Washa ble Front Panel • • • • Remote Control Self-illuminating Button • • • • Catechin Air Purifying Filter − − − − Trap dust, tobacco smoke and tiny particles − − − − Prevent the growth of bacteria and viruses trapped 19.2. PRINT PATTERNI NDOOR UNIT PRINTED CIRCUIT BOARD TOP VIEW 77 19.3. PRINT PATTERNI NDOOR UNIT PRINTED CIRCUIT BOARD BOTTOMVIEW 78 19.4. PRINT PATTERNI NDICATOR DISPLAY 78 • • • • Quality Improvemen t − − − − Gas leakage protection − − − − Prevent compressor reversecycle − − − − 2-stage OLP to protect compressor − − − − Noise prevention during soft dry operation − − − − Blue Coated Conde nser − − − − High resistance to corrosion. • • • • Operation Improvement − − − − Quiet mode to provide extra quiet operation − − − − Oxygen mode to supply oxygen enrich air to indoor room. • • • • Long Installation Piping − − − − XC9CK, long piping up to 10 meter − − − − XC12CK , long piping up to 15 meter • • • • 24-hour Timer Setting 1 Features 2 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
2 Functions CHECK AUTOAU TO TEMP AUTOAU TOONOFF AU TOAU TODRYFA NCOOLCOOL FA NFA N AUTOAU TO RESET CLOCK MODE FAN SPEED OFFCANCEL ONSET12 3 TIMER OFF ON/ QUIETAIR SWINGAUTOMANUAL 2 Remote Control Operation OFF / ONOFF / ON Room Temperature SettingTEMP. Operation Mode Selection AUTOAutomatic Operation Mode COOLCooling Operation Mode DRYSoft Dry Operation Mode FANAir Circulation Mode MODE TIME Time / Timer Setting Hours and minutes setting. Clock Setting Current time setting. Ionizer Operation OFF / ON Indoor Fan Speed Selection FAN SPEED FAN Low Fan Speed FAN Medium Fan Speed FAN High Fan Speed AUTOAutomatic Fan SpeedFAN Vertical Airflow Direction Control 24-hour, OFF / ON Real Timer Setting. ON-TIMER OFF-TIMER Timer Operation Selection SET CANCEL Timer Operation Set / Cancel ON Timer and OFF Timer setting and cancellation. CLOCK AIR SWING AUTO Automatic Vertical Airflow Direction Control MANUALVertical Airflow Direction Manual Control (5 stages of adjustment) Oxygen Mode Operation OFF/ON Quiet Mode Operation OFF/ON QUIET Cooling, Soft Dry Operation. Temperature Setting (16°C to 30°C) Automatic Operation Operation with 2°C higher than standard temperature. Operation with standard temperature. Operation with 2°C lower than standard temperature. Self illuminating b utton 2 3 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Indoor Unit Ionizer Control Ionizer control for generate negative ion in discharge air. Indoor Fan Speed Control High, Medium and Low. Automatic Fan Speed Mode _Cooling : Fan rotates at Hi, Me and SLo speed. Deodorizing control is available. _Soft Dry : Fan rotates at Lo- speed. Deodorizing control is available. Automatic air swing and manual adjusted by remote control for vertical airflow. Manually adjusted by hand for horizontal airflow. Airflow Direction Control Automatic Operation Button Press for < 5s to operate Automatic operation mode. (Used when the remote control cannot be used.) Press continuously for 5s or < 10s to operate Test Run/Pump down. Beep sound will be heard at the 5th second. (Used when test running or servicing.) Press continuously for 10s or < 15s to omit or resume the remote control signal receiving sound. Beep, beep sound will be heard at the 10th second. AUTO OFF / ON Operation Indication Lamps (LED) POWER(Green)......... Lights up in operation, blinks in Automatic Operation Mode judging. Operation Mode Cooling, Soft Dry, Air Circulation and Automatic Mode. Oxygen Operation To supply oxygen enrich air.Time Delay Safety Control Restarting is inhibited for appro. 3 minutes. Starting Current Control Quiet Operation To provide quiet operation.7 Minutes Time Save Control Cooling Operation only. Indoor fan motor is delayed for 1.6 seconds when indoor, outdoor fan motor and compressor starts simultaneously. Random Auto Restart Control Operation is restarted randomly after power failure at previous setting mode. Anti-Freezing Control Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry) Press continuously for 15s and above to testify oxygen operation. Beep, beep, beep sound will be heard at the 15th second. QUIET (Orange)......... Lights up in Quiet Mode Operation. TIMER (Orange)......... Lights up in Timer Setting. (Green)... .... Lights up in Oxygen Mode Operation. ION (Green)............ Lights up in Ionizer Mode Operation. 4 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Outdoor Unit • To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control • Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector • 2-Stage OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows to compressor. (Refer circuit diagram for OLP characteristic) Compressor Reverse Rotation Protection Control Outdoor Fan Operation Control • Temperature Fuse. 5 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
3 Product Specifications UnitCS-XC9CKQCU-XC9CKQ Power SourcePhase, Voltage, CycleSingle, 230, 60 Hz Cooling CapacitykW (BTU/h)2.76 (9,420) Moisture Removall/h (Pint/h)1.6 (3.4) Airflow MethodOUTLET INTAKE SIDE VIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)6.8 (240)— Indoor Air (Me)m3/min (cfm)8.0 (280)— Indoor Air (Hi)m3/min (cfm)9.9 (350)32.6 (1,150) Indoor Air (SHi)m3/min (cfm)10.9 (380)— Noise LeveldB (A)High 36, Low 26High 49 Power level dBHigh 49High 64 Electrical DataInput PowerW790 Running CurrentA3.7 EERW/W (BTU/hW)3.49 (11.8) Starting CurrentA23.0 Piping Connection Port (Flare piping)inch inchG ; Half Union 3/8” L ; Half Union 1/4”G ; 3-way valve 3/8” L ; 2-way valve 1/4” Pipe Size (Flare piping)inch inchG ; (gas side) 3/8” L ; (liquid side) 1/4”G ; (gas side) 3/8” L ; (liquid side) 1/4” Drain HoseInner diametermm12— Lengthmm650— Power CordLengthm1.9— Number of core-wire3 (1.5 mm2)— DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)9 -9/32 (236)11 - 3/8 (289) Net Weightlb (kg)22 (10.0)68 (31.0) CompressorType—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—600 Air CirculationTypeCross-flow FanPropeller Fan MaterialAS + Glass Fiber 20%PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW42.072.4 RatedOutputW1530 Fan SpeedLowrpm780— Mediumrpm920— Highrpm1,140835 SuperHighrpm1,250— Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium (Blue Coat) Fin TypeSlit FinLouver Fin Row / Stage(Plate fin configuration, forced draft) 2×151×20 FPI1917 Size (W × H × L)mm610 × 315 × 25.4841 × 508 × 22 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—SUNISO 4GDID or ATMOS M60 (290) Refrigerant (R-22)g (oz)—890 (31.4) Thermosta tElectronic Control— Protection Device—2 Stage Overload Protector 6 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Note: UnitCS-XC9CKQCU-XC9CKQ Capillary TubeLengthmm—720 Flow Ratel/min—11.0 Inner Diametermm—1.5 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—15 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC • • • • Specifications are subject to change without notice for further improvement. 7 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
UnitCS-XC12CKQCU-XC12CKQ Power SourcePhase, Voltage, CycleSingle, 230, 60 Hz Cooling CapacitykW (BTU/h)3.58 (12,220) Moisture Removall/h (Pint/h)2.1 (4.4) Airflow MethodOUTLET INTAKE SIDE VIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)7.3 (260)— Indoor Air (Me)m3/min (cfm)8.7 (310)— Indoor Air (Hi)m3/min (cfm)10.2 (360)32.6 (1,150) Indoor Air (SHi)m3/min (cfm)10.5 (370)— Noise LeveldB (A)High 39, Low 29High 49 Power level dBHigh 52High 64 Electrical DataInput PowerkW1.12 Running CurrentA5.1 EERW/W (BTU/hW)3.20 (10.9) Starting CurrentA33.0 Piping Connection Port (Flare piping)inch inchG ; Half Union 1/2” L ; Half Union 1/4”G ; 3-way valve 1/2” L ; 2-way valve 1/4” Pipe Size (Flare piping)inch inchG ; (gas side) 1/2” L ; (liquid side) 1/4”G ; (gas side) 1/2” L ; (liquid side) 1/4” Drain HoseInner diametermm12— Lengthmm650— Power CordLengthm1.9— Number of core-wire3 (1.5 mm2)— DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)9 - 9/32 (236)11 - 3/8 (289) Net Weightlb (kg)22 (10.0)79 (36.0) CompressorTypeRotary (1 cylinder) rolling piston type MotorTypeInduction (2-poles) RatedOutputkW—0.85 Air CirculationTypeCross-flow FanPropeller Fan MaterialAS + Glass Fiber 20%PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW42.072.4 RatedOutputW1530 Fan SpeedLowrpm900— Mediumrpm1,080— Highrpm1,260835 SuperHighrpm1,300— Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium (Blue Coat) Fin TypeSlit FinLouver Fin Row / Stage(Plate fin configuration, forced draft) 2×151×20 FPI2117 Size (W × H × L)mm610 × 315 × 25.4841× 508 × 22 Refrigerant Control Device—Capilary Tube Refrigeration Oil(cm3)—SUNISO 4GDID or ATMOS (350) Refrigerant (R-22)g (oz)—780 (27.5) Thermosta tElectronic Control— Protection Device—2 Stage Overload Protector Capillary TubeLengthmm—490 Flow Ratel/min—18.0 Inner Diametermm—1.7 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube 8 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Note: UnitCS-XC12CKQCU-XC12CKQ Compressor CapacitorµF, VAC—30 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC • • • • Specifications are subject to change without notice for further improvement. 9 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
4 Dimensions 10 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ