9 Operating Instructions 31 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
- 8˚C (COOL) Check performance START cooling ~15 Min. C H E C K AUT O AUTOTEM PAU TO AU TOO NOFFAU TO AU TO DRY DRY FA FANCOOL COOLFA FAN AU TO AU TO R E S E T CL OC K M O DEFA N SP EE DOF FCANCE LONS E T12 3T I M E R O FFO N/Q U I E TAIR SWINGA UT OMA NU A L2Batteries Fans obstructed? Check1.2. OK? Same type!Open / removeInsert batteries / Set clock PREPARATIONSInstallation: see enclosed installation instruction! Insert batteries / close UsePlug in refer page 38 OPEN front Panel Remove AIR filters Place PURIFYING filters Place AIR filters CLOSE front Panel Indoor unit RechargeableConfirmSet current time immediatelyPress Set time Year~1 Pre-season inspections Call Service For extended non-operation dry internal parts STARTUnplug Remove batteries 2-3[h] OFF After several seasons and due to operational conditions, performance may be reduced by dust or there may be unpleasant smells.Recommended InspectionsConsult an authorized distributor for inspection! Check-+ Press button Plug / breaker 35 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
10 Installation Instructions Required tools for Installation Works 1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter 2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3.Electric drill, hole core drill (ø70 mm)7.Reamer11.Thermome ter15.Vacuum pump 4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold 10.1. Safety Precautions • • • • Read the following“SAFETY PRECAUTIO NS”carefully before installa tion. • • • • Electrical work must be installe d by a license d electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installe d. • • • • The caution items stated here must be followe d because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installa tion due to ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications. This indication shows the possibility of causing death or serious injury. This indication shows the possibility of causing injury or damage to properties only. The items to be followe d are classified by the symbols: Symbol with background white denotes item that is PROHIBITED from doing. • • • • Carry out test running to confirm that no abnormality occurs after the installa tion. Then, explain to user the operation, care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference. 1.Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 2.Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 3.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or electrical shock. 4.Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly done, the set will drop and cause injury. 5.For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 6.Use the specified cable (1.5 mm2) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. 7.Wire routing must beproperly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. 8.Whencarrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury. 9.Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock. 10.Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock. 39 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. 1.Selection of the installation location. Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. 2.Power supply connection to the room air conditioner. Connect the power supply cord of the room air conditioner to the mains using one of the following method. Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, permanent connection of this room air conditioner to the power supply is prohibited. 1. Power supply connection to the receptacle using a power plug. Use an approved 15A/16A power plug with earth pin for the connection to the socket. 2. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3 mm contact gap. 3.Do not release refrigerant. Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite. 4.Installation work. It may need two people to carry out the installation work. 5.Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 40 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ