    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							5 Refrigeration Cycle Diagram
    12
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							6 Block Diagram
    13
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							REMARKS
    B: BLUEP: PINK
    BR: BROWNR: RED
    BL: BLACKW: WHITE
    G: GREENY: YELLOW
    GRY: GRAYY/G: YELLOW/G REEN
    O: ORANGE
    Resistance of Indoor Fan Motor Windings
    MODELCS-XC9CK
    CS-XC12CK
    CONNECTIONCWA921181
    BLUE-YELLOW390Ω
    YELLOW-RED390Ω
    Note: Resistance at 20°C/25°C of ambient temperature.
    Resistance of Outdoor Fan Motor Windings
    MODELCU-XC9CK
    CU-XC12CK
    CONNECTIONCWA951128
    BLUE-YELLOW210.7Ω
    YELLOW- RED196.5Ω
    Note: Resistance at 20°C of ambient temperature.
    Resistance of Compressor Windings
    MODELCU-XC9CKCU-XC12CK
    CONNECTION2R13C236BSC2P19S236A1L
    C-R3.298Ω2.237Ω
    C-S5.500Ω2.710Ω
    Note: Resistance at 20°C/25°C of ambient temperature.
    7 Wiring Diagram
    14
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							8 Operation Details
    8.1. Indoor Fan Speed Control
     
        • 
    • •  • 
    Auto Fan Speed Control
    When set toAuto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
     
        • 
    • •  • 
    Manual Fan Speed Control
    Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
    control.
    15
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Coolin g in operation according to Remote Control setting.
    Time DelaySafety Control (3 minutes)
    7 minutes TimeSave Control
    Starting Current Control
    Anti-Freezing Control
     
        • 
    • •  • 
    If the temperature of the indoor heat exchan ger falls
    continuously below 2°C for 4 minutes or more, the
    compressor turns off to protect the indoor heat exchan ger
    from freezing. The fan speed setting remains the same.
     
        • 
    • •  • 
    Compressor will restart again when the indoor heat
    exchan ger temperature rises to 10°C (Recovery).
    3 minutes waiting of Time Delay Safety Control is valid for
    Cooling Operation.
    Compressor Reverse Rotation Protection Control
    8.2. Cooling Mode Operation
     
        • 
    • •  • 
    W hen the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
     
        • 
    • •  • 
    W hen the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes.
     
        • 
    • •  • 
    The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor
    ON temperature and OFF temperature.
     
        • 
    • •  • 
    W hen the compressor outdoor fan motor and indoor fan motor are simultaneousl y started, the indoor fan motor will operate 1.6
    second later.
     
        • 
    • •  • 
    If the compressor is operating continuously for 5 minutes or longer and thetemperature difference between intake air and
    indoor heat exchan ger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically .
    (Time Delay Safety Control is valid)
    !
    T = Intake air temperature - Indoor heat exchanger temperature
    This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
    16
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Automatic Fan Speed Mode
    Cooling Operation Time Diagram
    When Automatic Fan Speed is selected at Remote Control during cooling operation.
     
        • 
    • •  • 
    Fan speed rotates in the range of Hi to Me.
     
        • 
    • •  • 
    Deodorizing Control.
    17
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Quiet Operation Control
    (For Coolin g Mode or cooling region of Soft Dry Mode)
     
        • 
    • •  • 
    Purpose of this operation is to provide quite cooling operation compare to normal operation.
     
        • 
    • •  • 
    W hen the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
    2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
     
        • 
    • •  • 
    Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
     
        • 
    • •  • 
    Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
    After that, it goes back to Lo cool (However Quiet LED remains on).
     
        • 
    • •  • 
    Manual Fan Speed:-
     
        − 
    − −  − 
    RPM control during Lo cool
     
        − 
    − −  − 
    RPM control during Hi & Me cool
     
        • 
    • •  • 
    Auto Fan Speed:-
     
        • 
    • •  • 
    Quiet Mode Operation will stop if:-
     
        − 
    − −  − 
    Quiet mode button is pressed again.
     
        − 
    − −  − 
    Stopped by ON/OFF switch.
     
        − 
    − −  − 
    Timer OFF activates.
     
        − 
    − −  − 
    W hen change mode to Air Circulation mode.
    18
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Time DelaySafety Control
    Starting Current Control
    Anti-Freezing Control
    Compressor Reverse Rotation Protection Control
    Automatic Fan Speed Mode
    8.3. Soft Dry Mode Operation
     
        • 
    • •  • 
    The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
    then Soft Dry operation will start.
     
        • 
    • •  • 
    During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
     
        • 
    • •  • 
    The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
    off, it stops for 6 minutes.
     
        • 
    • •  • 
    Once the compressor stops, it will not start for 3 minutes during Cooling operation.
     
        • 
    • •  • 
    Same as Starting Current Control for Coolin g Mode operation.
     
        • 
    • •  • 
    Same as Anti-Freezing Control for Coolin g Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
    stops.)
     
        • 
    • •  • 
    Same as Compressor Reverse Rotation Protection Control for Coolin g Mode Operation. (For Soft Dry region, 6 minutes waiting
    is valid during compressor stops.)
    When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
     
        • 
    • •  • 
    Fan speed off and on at Lo- speed.
     
        • 
    • •  • 
    Deodorizing Control.
    19
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    							Soft Dry Operation Time Diagram
    Quiet Operation Control
    (For Dry region of Soft Dry Mode)
    20
    CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ 
    						
    All Panasonic manuals Comments (0)