Panasonic Cs Xc12ckq Cs Xc9ckq Repair Manual
Here you can view all the pages of manual Panasonic Cs Xc12ckq Cs Xc9ckq Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 61
1. Remove the screw and Particular Piece. 2. Take out the Oxygen tube. 3. Slide out the Filter - Oxygen Generator. 4. Take out the Discharge and Inlet Oxygen tube. (Make sure connect back to Original place.) 5. Releas e the connectors. 6. Remove the 3 screws Control Board. 7. Remove th ground screw. 8. Remove the 4 screws at the bottom vacuum pump and take out the vacuum pump. 12.2.2. Filter - Oxygen Generator and Vacuum Pump Removal Procedures 61 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 62
• • • • Remote Control Reset When thebatteries are inserted for the first time, or the batteries are replaced, all the indications will blink and the remote control might not work. If this happen, remove the cover of the remote control and you will find a resetting terminal, and by shorting it with a minus screwdriver, it will return to normal. • • • • Changing the wireless remote control transmission code When twoindoor units are installe d in the same room, in order to prevent...
Page 63
13.1. Refrigeration cycle system In order to diagnose malfun ctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insuffic ient insulation, problem with the power source, malfun ction of a compressor and a fan. The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions, the standard values for them are shown in the table to the right. 13 Troubleshooting Guide 63 CS-XC9C KQ CU-XC 9CKQ /...
Page 64
13.1.1. Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Condition of the air conditionerLow PressureHigh PressureElectric current during operation Insufficient refrigerant (gas leakage) Clogged capillary tube or Strainer Short circuit in the indoor unit Heat radiation deficiency of the outdoor unit Inefficient compression • • • • Carry out the measurements of pressure, electric current, and temperature fifteen minutes after an operation is...
Page 67
15 Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 67 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 68
16 Replacement Parts List REF. NO.PART NAME & DESCRIPTIONQTY.CS-XC9CKQCS-XC12CKQREMARKS1CHASSY COMPLETE1CWD50C1246← ←← ←2FAN MOTOR1CWA921181← ←← ←03CROSS FLOW FAN COMPLETE1CWH02C1028← ←← ←4BEARING COMPLETE1CWH64C1005← ←← ←5SCREW - CROSS FLOW FAN1CWH4580304← ←← ←6EVAPORATOR1CWB30C1382CWB30C13817FLARE NUT1CWH6002140(1/4”)← ←← ←8FLARE NUT1CWT25005 (3/8”)CWT25007 (1/2”)9INTAKE AIR SENSOR HOLDER1CWH32142← ←← ←10DISCHARGE GRILLE COMPLETE1CWE20C2262← ←← ←11VERTICAL VANE12CWE241068← ←← ←12CONNECTING...
Page 69
17 Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 69 CS-XC9C KQ CU-XC 9CKQ / CS-XC12CK Q CU-XC12 CKQ
Page 70
18 Replacement Parts List REF. NO.PART NAME & DESCRIPTIONQTY.CU-XC9CKQCU-XC12CKQREMARKS1CHASSY ASS’Y1CWD50K2071← ←← ←2SOUND PROOF MATERIAL1CWG302110← ←← ←3FAN MOTOR BRACKET1CWD541030← ←← ←4SCREW - FAN MOTOR BRACKET2CWH551059← ←← ←5FAN MOTOR1CWA951128← ←← ←06SCREW - FAN MOTOR MOUNT3CWH55406← ←← ←7PROPELLER FAN ASS’Y1CWH03K1006← ←← ←8NUT - PROPELLER FAN1CWH56053← ←← ←9COMPRESSOR12R13C236BSC2P19S236A1L010ANTI - VIBRATION BUSHING3CWH50077← ←← ←11NUT - COMPRESSOR MOUNT3CWH56000← ←← ←12CONDENSER1CWB32C1153←...