Page 161
PCB INSTALLATION 2. PCB Installation and Startup 2-8 CPRU Installation (Figures 2-3 through 2-7) 1. Install the battery on the CPRU using the tie wrap. 2. Connect the battery to the BAT connector with the red wire up (Figure 2-3). 3. Insert the CPRU into the CPU slot in the Main Cabinet (Figure 2-4). Figure 2-3 CPRU BATTERY INSTALLATION4. Set the MOH jumper for internal/external MOH source (Figure 2-5). Use the HTVR potentiometer to adjust MOH volume. Note:When the S jumper is set for internal MOH, and...
Page 162
2. PCB Installation and Startup2-9 PCB INSTALLATION 5. Set DIP switch 1 ONfor system data and customer program- ming data loaded from the disk. Set DIP switch 1 OFFfor system data from disk and customer programming data loaded from RAM. Figure 2-5 SETTING MOH SOURCE AND SYSTEM DATA SOURCE6. Insert the software disk into the disk drive (Figure 2-6). 7. Install the 10-pin to 16-pin filter cable after 48FU installation. Figure 2-6 INSTALLING THE SYSTEM DISK 92000 - 13 INT INTEXT EXTONOFF 12 ON - Cold...
Page 163
PCB INSTALLATION 2. PCB Installation and Startup 2-10 16DSTU Description The 16DSTU PCB provides: - 16 digital extension circuits - 16 extension status LEDs - One 16-pin connector(s) for 48FU filter unit connection - One PCB status LED - One run/block switch 16DSTU Installation(Figure 2-7) To install a 16DSTU PCB: 1. Set the run/block switch DOWN. 2. Install the 16DSTU into a slot. 3. Install the 16-pin filter cable(s) after 48FU installation. 4. Set the 16DSTU run/block switch UP. Figure 2-7 16DSTU...
Page 164
2. PCB Installation and Startup2-11 PCB INSTALLATION 8ASTU/16ASTU Description The ASTU PCB provides: - 8/16 analog extension circuits - 8/16 extension status LEDs - one/two 16-pin connectors for 48FU filter unit connection - one PCB status LED - one run/block switch 8ASTU/16ASTU Installation (Figure 2-8) 1. Set the run/block switch DOWN. 2. Install the ASTU into the slot. 3. Install the 16-pin filter cable(s) after 48FU installation. 4. Set the ASTUs run/block switch UP. Figure 2-8 ASTU INSTALLATION...
Page 165
PCB INSTALLATION 2. PCB Installation and Startup 2-12 8ATRU-LS1 Description The 8ATRU-LS1 PCB provides: - 8 analog loop start line/trunk circuits - 8 trunk status LEDs - Six 2/3 pin jumpers for ground start or PF operation - One 16-pin connector for 24FU filter unit connection - One PCB status LED - One run/block switch 8ATRU-LS1 Installation (Figure 2-9) Note:Refer to instructions for the GSAU (ground start) or PFTU (power failure) PCBs if either is required before installing the 8ATRU. 1. Set the...
Page 166
2. PCB Installation and Startup2-13 PCB INSTALLATION 8GSAU Description The GSAU PCB provides 8 analog ground start line/trunk circuits. Note:When a GSAU PCB is installed, loop start operation and PF operation cannot be used. 8GSAU Installation(Figures 2-10 and 2-11) 1. If the 8ATRU-LS1 is installed: Set the 8ATRU-LS1 run/block switch UP, remove the 16-pin filter cable(s) from the 8ATRU-LS1, and remove the PCB from the cabinet. 2. Remove all six jumpers from connectors CN4 and CN5 from the 8ATRU-LS1....
Page 167
PCB INSTALLATION 2. PCB Installation and Startup 2-14 8GSAU Installation (cont’d) 3. Install the GSAU on the 8ATRU-LS1. GSAU jumper J1 (female) plugs into 8ATRU-LS1 CN4 (male). GSAU jumper J2 (female) plugs into 8ATRU-LS1 CN5 (male). GSAU jumper J3 (male) plugs into 8ATRU-LS1 CN3 (female). 4. Install the 8ATRU-LS1 into a PCB slot. 5. Set the run/block switch UP. 6. Install the filter cable to the 24FU. Figure 2-11 INSTALLING THE GSAU 92000 - 22A CN1RUN BLK Circuits for Trunks 1-88ATRU Status LED...
Page 168
2. PCB Installation and Startup2-15 PCB INSTALLATION 4ATRU-LD1 Direct Inward Dial (DID) PCB Description The 4ATRU-LD1 DID Trunk PCB provides: - 4 DID trunk circuits - 4 DID trunk status LEDs - One 16-pin connector for 24FU filter unit connection - One PCB status LED One run/block switch 4ATRU-LD1 Installation (Figure 2-12) 1. Set the run/block switchDOWN. 2. Install the 4ATRU-LD1 into a slot. 3. Install the 16-pin filter cable after 24FU installation. 4. Set the run/block switch UP. Figure 2-12...
Page 169
PCB INSTALLATION 2. PCB Installation and Startup 2-16 4ATRU-EMI Tie Line PCB Description The 4ATRU-EMI Tie Line PCB provides: - 4 Tie line circuits - 4 Tie line status LEDs - One 16-pin connector for 24FU filter unit connection - One PCB status LED - One run/block switch 4ATRU-EMI Installation (Figure 2-13) 1. Set the run/block switch DOWN. 2. Install the 4ATRU-EMI into a slot. 3. Install the 16-pin filter cable after 24FU installation. 4. Set the run/block switch UP. Figure 2-13 4ATRU-EMI TIE LINE PCB...
Page 170
2. PCB Installation and Startup2-17 PCB INSTALLATION 4PGDU Description - 8 alarm/fax sensors - 4 external page or door box circuits - 4 potentiometers for External Page/Door Box volume control - 4 switches to determine page/door box circuit function - 4 dedicated dry relay contacts for page/door box operation - Two 16-pin connectors for 48FU filter unit connection - One PCB status LED 4PGDU Installation (Figure 2-14) 1. Set switches SW1-4 according to circuit type required. Note:Dip switches are read top...