Nitsuko 24i/28i/124i/384i Hardware Manual
Here you can view all the pages of manual Nitsuko 24i/28i/124i/384i Hardware Manual. The Nitsuko manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 121
5. Data and SMDR5-17 SMDR Using SMDR Station Message Detail Recording (SMDR) provides a record of the system’s outside calls. Typically, the record outputs to a customer-provided printer, terminal or SMDR data collection device. Use SMDR when you need to monitor the usage at each extension and trunk. Installing SMDR (Figure 5-15) 1. Locate an available DDK connector in a station (B) block. 2. For the DDK connector chosen, cross-connect the associated wire pair from the A or B block to the cross-connect...
Page 122
5. Data and SMDR 5-18 SMDR 8. Plug a line cord into the modular jack and the telephone or module. 9. Plug the RS-232-C cable into the SMDR and the DCI/3-DCI port. Programming SMDR Note:For DCI units, the data (software) port number is the same as the extension’s port number. DCI Modules use the extension’s port number and the next two port num- bers for data (software) port numbers. 0404 - SMDR Options, Items 1, 2, 4-6 Set the various print options for SMDR. 0404 - SMDR Options, Item 3: SMDR Printer...
Page 123
6. Specifications and Parts6-1 Section 6, SPECIFICATIONS AND PARTS LIST In this section . . . . . . . . . . . . . .PageSpecifications . . . . . . . . . . . . . . . . . . . . . . .6-2 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
Page 124
6. Specifications and Parts 6-2 SPECIFICATIONS 28i PCBs Capacities 4ATRU Analog Trunk PCB: 4 8DSTU Digital Station PCB: 1 * 4ASTU Analog Station PCB: 2 * 4CIDU Caller ID Daughter Board: 4 (mounts on 4ATRU) 4GSAU Ground Start Daughter Board: 4 (mounts on 4ATRU) 4PGDU 4 Page/Door Box PCB: 2 4DTDU Dial Tone Detection PCB: 2 24CPRU Central Processing Unit: 1 LAPBU Unit: 1 (mounts on 24CPRU) REJ Recording Jack Unit: 20 (either 92265 or 80175) *Due to the system load factors, no more than two station PCBs...
Page 125
6. Specifications and Parts6-3 SPECIFICATIONS 124i PCBs Capacities 4ATRU Analog Trunk PCB: 13 (8 max. per cabinet) 8DSTU Digital Station PCB: 9 (3 max. per cabinet) 4ASTU Analog Station PCB: 16 if no DSTU PCB installed 15 with DSTU PCB installed (8 max. per cabinet) 2EMTU E&M Tie Line PCB: 13 (5 max. per cabinet) 2DIDU DID Trunk PCB: 13 (5 max. per cabinet) BRIU BRI Interface PCB: 13 (5 max. per cabinet) PRIU T1/PRI Interface PCB: 2 4CIDU Caller ID Daughter Board: 13 (mounts on 4ATRU) 4GSAU Ground Start...
Page 126
6. Specifications and Parts 6-4 SPECIFICATIONS External Paging Output Impedance: 600 Ohm Output Level: Nominal 250 mV (-10 dBm) Maximum Output: 400 mV RMS Environmental Specifications Cabinets and Key Telephones Temperature: 0-45 oC (32-113 oF) Humidity: 10-95% (non-condensing) Door Box Temperature: -20-60 oC (-4-140 oF) Humidity: 10-95% (non-condensing) Power Requirements A dedicated 110 VAC 60 Hz circuit located within seven feet of the cabinet is required. You should install a separate dedicat- ed...
Page 127
6. Specifications and Parts6-5 SPECIFICATIONS 124i Power Supply Specifications (cont.) Main Exp. Exp. 3 Cabinet Parameter Equipment Cabinet 1 Cabinet 2 Total Output Power 106W 106W 106W 318W Watts 33.3% 33.3% 33.3% @ full load % of Total AC Input I 1.53A 1.53A 1.53A 4.59A @ full load VA 184VA 184VA 184VA 551VA @ 120V Avg. Input Power 120W 120W 120W 360W @ 120V KWh .184KWh .184KWh .184KWh .551KWh @ AC Input Ix120V BTU 628btu 628btu 628btu 1884btu KWh x 3413 System Name Plate Rating: 120V, 50/60 Hz, 2.5A...
Page 128
6. Specifications and Parts 6-6 SPECIFICATIONS Door Box/External Paging Contacts Output Impedance: 600 Ohm Output Level: Nominal 250 mV (-10 dBm) Maximum Output: 400 mV RMS Configuration: Normally open 124i Mechanical Specifications Equipment Width Depth Height Weight Cabinet 16.5”6”13.5”7 lbs 16/32 Button Keyset 8 5/8”9 3/8”3 1/4”2 lbs 2 oz Super Display 8 5/8”9 3/8”3 7/8”2 lbs 8 oz DSS Console 7 13/16” 8 7/8” 2 3/4” 1 lb 6 oz Digital Single Line 6 3/4” 8 5/8” 3 3/4” 1 lb 7 oz Door Box 4” 1 1/2” 5 3/16”...
Page 129
6. Specifications and Parts6-7 SPECIFICATIONS FCC Registration Information Model: 28i and 124i Manufacturer: Nitsuko America FCC Part 15 Registration: Class A Sample FCC Registration Number: 1ZDTHA-21819-KF-E (Refer to the label on the Main Cabinet for the FCC RegistrationNumber.)Reg. MTS/WATS Mfrs. Port Ringer SOC Network Status Interfaces Identifier Eq. Number JacksOriginal 02LS2 4ATRU 0.9B9.0FAS26.0P R J 11 C BGM/MOH Music Source Input Input Impedance: 600 Ohm Input Level: Nominal 250 mV (-10 dBm)...
Page 130
6. Specifications and Parts 6-8 PARTS LIST Cabling Requirements 1. Do not run station cable in parallel with the AC source, telex or computer, etc. If the cables are near cable runs to those devices, use shielded cable with grounded shields or install the cable in conduit. 2. When cables must be run on the floor, use cable protectors. 3. Cable runs for key telephones, single line telephones, Door Boxes and 3-ACI Modules must be a dedicated, isolated cable pair.Device Cable Type Cable Run Length (ft)...