4. Optional Equipment 4-10 NIGHT MODE SELECTION Night Mode Selector Switch Description The Night Mode Switch relay closes when the system detects either an open or closure on the MISC block NIGHT SW termi- nals. System programming determines whether the contact is normally open or normally closed. Maximum 9v DC is output to the switch when open, and 5mA DC when shorted. Refer to Night Servicein the Software Manual for additional details. Connecting a Night Mode Selector Switch (Figure 4-5) 1. Run...
Page 202
4. Optional Equipment4-11 OPA/VAU OPA/VAU Description OPA/VAU provides three voice channels to allow the system to automatically answer calls on designated trunks, play a greet- ing, and provide dialing options to the callers. Refer to Voice Announce Unit in the Software Manual for a detailed descrip- tion of OPA operation. The three-channel OPA/VAU requires one digital extension cir- cuit. A second three-channel expansion PCB requires a second digital extension circuit. Station Cabling for the OPA/VAU...
Page 203
4. Optional Equipment 4-12 OPA/VAU Installing an Expansion PCB(Figure 4-7) 1. Punch down one-pair station cable to a cross-connect block. 2. Run one-pair cross-connect from the cross-connect block to the extension (B) block. 3. Terminate the station cable to the BLK/YLW leads of the OPA/VAU modular jack. 4. Install bridging clips on the extension (B) block. Figure 4-7 OPA/VAU EXPANSION PCB INSTALLATION 625 Modular Jack BLK YELRED GRN 920 - 166C J3 VAU Module To Digital Extension Circuit To Digital...
Page 204
4. Optional Equipment4-13 2-OPX MODULE 2-OPX Description The 2-OPX Module provides two 2500 type analog circuits for connection to on-premise 2500 type single line devices (i.e., telephones, fax machines, modems, etc.) and to telco OL13B/C OPX circuits. Refer to Single Line Telephonesin theSoftware Manual for more details. Station Cabling for the 2-OPX Module The 2-OPX Module connects to a single digital extension cir- cuit for power/signaling. However, the 2-OPX automatically disables the next adjacent...
Page 205
4. Optional Equipment 4-14 2-OPX MODULE 2-OPX Installation (Figure 4-8) The 2-OPX is designed for desk/shelf mounting. A 625 modular jack is required for the 2-OPX. 1. Ground the 2-OPX Module by connecting a 14 AWG ground wire from the FG lug to a known earth ground. 2. Install a 625 modular jack near the 2-OPX module.3. Terminate the station cable from the cross-connect block to GRN/RED of the 2-OPXs 625 modular jack. 4. Plug a 4-conductor line cord into the jack. Plug the other end into the modular...
Page 206
4. Optional Equipment4-15 POWER FAILURE Power Failure Description The system allows 4 loop start lines per cabinet to be bridged to designated extensions for basic telephone service during a power failure. The power failure operation occurs during a commercial power failure, and is not affected by PCB failure. Refer to the chart below for PF cross-connections. Note:An 8ATRU-LS1 equipped with an 8GSAU ground start PCB cannot be equipped for power failure operation. In addi- tion, 4ATRU-EMI and 4ATRU-LD1...
Page 207
4. Optional Equipment 4-16 POWER FAILURE Figure 4-9 4PFTU POWER FAILURE CONNECTIONS 8ATRU PCB48FU PCB To 24FU PCB 25 Pair Cable PF 1 T PF 1 R . . PF 2 T PF 2 R . . PF 3 T PF 3 R . . PF 4 T PF 4 R PF Block Ribbon CableRibbon Cable 92000 - 158 CN1 RUN BLK
Page 208
4. Optional Equipment4-17 EXTERNAL PAGING External Page Description Four external page zone/door box circuits are provided by each 4PGDU installed. Each Door Chime Box/external page circuit provides a dry relay contact. Refer to Paging, Externalin the Software Manual for additional details. Note:External paging can also be provided using a 3-ACI. Refer to page 4-21 for more on the 3-ACI Module. Installing an External Page System (Figures 4-10 and 4-11) 1. Set the dip switch on the 4PGDU for external...
Page 209
4. Optional Equipment 4-18 EXTERNAL PAGING Figure 4-10 4PGDU SWITCH SETTINGS 92000 - 15 CN1 CN2 VR1 VR2 VR3 VR4 Door Box and Paging CircuitsPage/Doorbox PCB Fax and Alarm Sensors Status LED (Normally flashing) Door Box/External Paging Zone 1 Volume Control Door Box/External Paging Zone 2 Volume Control Door Box/External Paging Zone 3 Volume Control Door Box/External Paging Zone 4 Volume ControlUse non-metallic alignment tool To 48FU Filter Unit To 48FU Filter Unit DHDoor Box/ Page Circuit 1 Door Box/...
Page 210
4. Optional Equipment4-19 EXTERNAL PAGING Figure 4-11 PGU BLOCK CUTDOWN 4PGDU PCB 48FU PCB 25 Pair Cable VR1 VR2 VR3 VR4 PG/DB 1 T PG/DB 1 R RLY 1 T RLY 1 R PG/DB 2 T PG/DB 2 R RLY 2 T RLY 2 R PG/DB 3 T PG/DB 3 R RLY 3 T RLY 3 R PG/DB 4 T PG/DB 4 R RLY 4 T RLY 4 R C Block Ribbon Cable 92000 - 154