    							PCB INSTALLATION
    2. PCB Installation
    and Startup
    2-8
    CPRU Installation (Figures 2-3 through 2-7)
    1. Install the battery on the CPRU using the tie wrap.
    2. Connect the battery to the BAT connector with the red wire
    up (Figure 2-3).
    3. Insert the CPRU into the CPU slot in the Main Cabinet
    (Figure 2-4).
    Figure 2-3  CPRU BATTERY INSTALLATION4. Set the MOH jumper for internal/external MOH source (Figure
    2-5). Use the HTVR potentiometer to adjust MOH volume.
    Note:When the S jumper is set for internal MOH, and an
    external MOH source is connected to the MISC block or to a
    3ACI, external MOH is sent to trunks programmed to receive
    external MOH.
    Figure 2-4  INSERTING THE CPRU
    92000 - 14
    CPRU PCB
    BAT
    92000 - 10
    Snap into ridges Red
    Black 
    						
    							2. PCB Installation
    and Startup2-9
    PCB INSTALLATION
    5. Set DIP switch 1 ONfor system data and customer program-
    ming data loaded from the disk.  Set DIP switch 1 OFFfor
    system data from disk and customer programming data
    loaded from RAM.
    Figure 2-5  SETTING MOH SOURCE
    AND SYSTEM DATA SOURCE6. Insert the software disk into the disk drive (Figure 2-6).
    7. Install the 10-pin to 16-pin filter cable after 48FU installation.
    Figure 2-6  INSTALLING THE SYSTEM DISK
    92000 - 13
    INT
    INTEXT
    EXTONOFF
    12
    ON - Cold Start (System and customer
    data loaded from disk)
    OFF - Hot Start (System data loaded
    from disk, customer
    data from RAM)
    Not used Internal
    MOH Selected
    or
    External
    MOH Selected
    92000 - 11 
    						
    							PCB INSTALLATION
    2. PCB Installation
    and Startup
    2-10
    16DSTU Description
    The 16DSTU PCB provides:
    - 16 digital extension circuits
    - 16 extension status LEDs
    - One 16-pin connector(s) for 48FU filter unit connection
    - One PCB status LED
    - One run/block switch
    16DSTU Installation(Figure 2-7)
    To install a 16DSTU PCB:
    1. Set the run/block switch DOWN.
    2. Install the 16DSTU into a slot.
    3. Install the 16-pin filter cable(s) after 48FU installation.
    4. Set the 16DSTU run/block switch UP.
    Figure 2-7  16DSTU INSTALLATION
    92000 - 21
    CN2CN3RUN
    Circuits for
    Stations 1-816 Digital Station Card
    Circuits for
    Stations 9-16
    Status LED
    (Normally flashing)
    Station 1
    Station 16
    Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked)
    Associated Station is...
    Connected and idle
    Not installed
    Off hook If LED is...
    Off
    Flashing
    OnTo 48FU
    Filter Unit
    To 48FU
    Filter Unit 
    						
    							2. PCB Installation
    and Startup2-11
    PCB INSTALLATION
    8ASTU/16ASTU Description
    The ASTU PCB provides:
    - 8/16 analog extension circuits
    - 8/16 extension status LEDs
    - one/two 16-pin connectors for 48FU filter unit connection
    - one PCB status LED
    - one run/block switch
    8ASTU/16ASTU Installation (Figure 2-8)
    1. Set the run/block switch DOWN.
    2. Install the ASTU into the slot.
    3. Install the 16-pin filter cable(s) after 48FU installation.
    4. Set the ASTUs run/block switch UP.
    Figure 2-8  ASTU INSTALLATION
    Associated Station is...
    Connected and idle
    Not installed
    Off hook If LED is...
    Off
    Flashing
    On
    92000 - 57
    CN2RUN
    BLK
    Circuits for
    Stations 1-8Analog Station PCB
    Status LED
    (Normally flashing)
    Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked) To 48FU
    Filter Unit
    Station 1
    Station 8 
    						
    							PCB INSTALLATION
    2. PCB Installation
    and Startup
    2-12
    8ATRU-LS1 Description
    The 8ATRU-LS1 PCB provides:
    - 8 analog loop start line/trunk circuits
    - 8 trunk status LEDs
    - Six 2/3 pin jumpers for ground start or PF operation
    - One 16-pin connector for 24FU filter unit connection
    - One PCB status LED
    - One run/block switch
    8ATRU-LS1 Installation (Figure 2-9)
    Note:Refer to instructions for the GSAU (ground start) or
    PFTU (power failure) PCBs if either is required before
    installing the 8ATRU.
    1. Set the run/block switch DOWN.
    2. Install the 8ATRU-LS1 into a slot.
    Note:Jumpers on connectors CN4 and CN5 must be installed
    when ground start operation or PF operation is not required.
    3. Install the 16-pin filter cable(s) after 24FU installation.
    4. Set the 8ATRU-LS1 run/block switch UP.
    Figure 2-9  8ATRU-LS1 INSTALLATION
    92000 - 22
    CN1RUN
    BLK
    Circuits for
    Trunks 1-8Analog Trunk PCB
    Status LED
    (Normally flashing)
    Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked) To 24FU
    Filter Unit
    Associated Trunk is...
    In use
    Idle If LED is...
    On
    Off
    Trunk 1
    Trunk 8CN6
    CN4CN5
    12 
    						
    							2. PCB Installation
    and Startup2-13
    PCB INSTALLATION
    8GSAU Description
    The GSAU PCB provides 8 analog ground start line/trunk
    circuits.
    Note:When a GSAU PCB is installed, loop start operation and
    PF operation cannot be used.
    8GSAU Installation(Figures 2-10 and 2-11)
    1. If the 8ATRU-LS1 is installed: Set the 8ATRU-LS1
    run/block switch UP, remove the 16-pin filter cable(s) from
    the 8ATRU-LS1, and remove the PCB from the cabinet.
    2. Remove all six jumpers from connectors CN4 and CN5 from
    the 8ATRU-LS1.
    Figure 2-10  THE GSAU GROUND START TRUNK PCB
    Continued on next page . . .
    Ground Start 
    Module
    J2
    J1
    92000 - 22B 
    						
    							PCB INSTALLATION
    2. PCB Installation
    and Startup
    2-14
    8GSAU Installation (cont’d)
    3. Install the GSAU on the 8ATRU-LS1.  GSAU jumper J1
    (female) plugs into 8ATRU-LS1 CN4 (male).  GSAU
    jumper J2 (female) plugs into 8ATRU-LS1 CN5 (male).
    GSAU jumper J3 (male) plugs into 8ATRU-LS1 CN3
    (female).
    4. Install the 8ATRU-LS1 into a PCB slot.
    5. Set the run/block switch UP.
    6. Install the filter cable to the 24FU.
    Figure 2-11 INSTALLING THE GSAU
    92000 - 22A
    CN1RUN
    BLK
    Circuits for
    Trunks 1-88ATRU
    Status LED
    (Normally flashing)
    GSAU Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked) To 24FU
    Filter Unit
    Associated Trunk is...
    In use
    Idle If LED is...
    On
    Off
    Trunk 1
    Trunk 8CN6
    CN4
    CN5
    12 
    						
    							2. PCB Installation
    and Startup2-15
    PCB INSTALLATION
    4ATRU-LD1 Direct Inward Dial (DID) PCB
    Description
    The 4ATRU-LD1 DID Trunk PCB provides:
    - 4 DID trunk circuits
    - 4 DID trunk status LEDs
    - One 16-pin connector for 24FU filter unit connection
    - One PCB status LED
    One run/block switch
    4ATRU-LD1 Installation (Figure 2-12)
    1. Set the run/block switchDOWN.
    2. Install the 4ATRU-LD1 into a slot.
    3. Install the 16-pin filter cable after 24FU installation.
    4. Set the run/block switch UP.
    Figure 2-12  4ATRU-LD1 INSTALLATION
    920 - 163a
    CN2
    RUNBLK
    Circuits for
    DID Trunks 1-4DID Trunk PCB
    Status LED
    (Normally flashing)
    Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked) To 24FU
    Filter Unit
    Associated Trunk is...
    In use
    Idle If LED is...
    On
    Off
    Trunk 1
    Trunk 4 
    						
    							PCB INSTALLATION
    2. PCB Installation
    and Startup
    2-16
    4ATRU-EMI Tie Line PCB Description
    The 4ATRU-EMI Tie Line PCB provides:
    - 4 Tie line circuits
    - 4 Tie line status LEDs
    - One 16-pin connector for 24FU filter unit connection
    - One PCB status LED
    - One run/block switch
    4ATRU-EMI Installation (Figure 2-13)
    1. Set the run/block switch DOWN.
    2. Install the 4ATRU-EMI into a slot.
    3. Install the 16-pin filter cable after 24FU installation.
    4. Set the run/block switch UP.
    Figure 2-13  4ATRU-EMI TIE LINE PCB INSTALLATION
    920-164A
    RUNBLK
    Tie Trunk PCB
    Switch Up - PCB On Line
    Switch Down - PCB Off Line
    (Blocked)
    Associated Trunk is...
    In use
    Idle If LED is...
    On
    Off
    Trunk 1
    Trunk 4
    Status LEDCircuits For
    Tie Trunks 1-4
    (Normally Flashing)
    (Normally Flashing) Power Supply Status LED 
    						
    							2. PCB Installation
    and Startup2-17
    PCB INSTALLATION
    4PGDU Description
    - 8 alarm/fax sensors
    - 4 external page or door box circuits
    - 4 potentiometers for External Page/Door Box volume
    control
    - 4 switches to determine page/door box circuit function
    - 4 dedicated dry relay contacts for page/door box operation
    - Two 16-pin connectors for 48FU filter unit connection
    - One PCB status LED
    4PGDU Installation (Figure 2-14)
    1. Set switches SW1-4 according to circuit type required.
    Note:Dip switches are read top (1) to bottom (4) upon
    power up.
    2. Install the 4PGDU into the slot.
    3. Install the 16-pin filter cable(s) after 48FU installation.
    Note:Use VR1-VR4 to adjust volume Door Box/Ext Page
    volume.
    Figure 2-14  4PGDU INTALLATION
    92000 - 15
    CN1
    CN2
    VR1
    VR2
    VR3
    VR4
    Door Box and
    Paging CircuitsPage/Doorbox PCB
    Fax and Alarm
    Sensors
    Status LED
    (Normally flashing)
    Door Box/External Paging Zone
    1 Volume Control
    Door Box/External Paging Zone
    2 Volume Control
    Door Box/External Paging Zone
    3 Volume Control
    Door Box/External Paging Zone
    4 Volume ControlUse non-metallic
    alignment tool To 48FU
    Filter Unit
    To 48FU
    Filter Unit
    DHDoor Box/
    Page Circuit 1
    Door Box/
    Page Circuit 2
    Door Box/
    Page Circuit 3
    Door Box/
    Page Circuit 4
    DH
    PG
    External Page
    CircuitDoor Box
    CircuitPG 
    						