NDA-24233 Issue 2Page 3-55
VisuaLink 128/384 Engineering Guide Console Command List
3.20  Camera Control Command
CAMS Request for Camera Direction Change 20-1
Description: Sets camera head swing control.  This command is valid only when an 
preset or auto mode camera is in use.  A control of Camera 2 is only valid 
when the camera is the EVI-D30 type.
Command Format: CMAS  p1 p2
p1: L1-2  :  local camera 1/ 2 control
R1-2  :  remote camera 1/ 2 control
p2: 1-9 :  preset number
Z x  :  zoom change
F x  :...

Page 82

Page 3-56NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.21  Option Control Command
POCS Pointer Control 21-1
VCTS Talker Detection Control 21-2
Description:
Activates or deactivates the on-screen pointer .  The pointer is displayed 
at the remote monitor.  This pointer can only be activated when both 
systems (Remote/Local) are set to a NEC mode.
Command Format: POCS p1 p2 p3
p1: ON/OFF  :  control on/off
p2: 1-99 : X-axis
p3: 1-99 : Y-axis
Response: Normal Response: When...

Page 83

NDA-24233 Issue 2Page 3-57
VisuaLink 128/384 Engineering Guide Console Command List
STPR SnapShot Transmission Request 21-3
SXMR Standard Display Screen Setting Request 21-4
Description: Sends a snapshot (still graphic) image to the remote site.
Command Format: STRP 
Response: Normal Response  OK
Error Response:  ERR01 
Description: Requests for a display setting change when going through the MCU.  This 
command is only valid when going through an NEC multi-point control 
unit, that has multi-screen...

Page 84

Page 3-58NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
SXST Request to Acquire Composite Screen Setting 21-5
Description: Request for status on the various video screens displays.  This command is only 
valid when going through an NEC multi-point control unit MCU5000A, that 
has multi-screen control capability.
Command Format: SXST p1 p2 p3
p1: Composite Screen Status
D7-D5  :  0 fixed
D4-D3  :  re-lineup  00: none 10: in the order of terminal number
D2  :  speaker display...

Page 85

NDA-24233 Issue 2Page 3-59
VisuaLink 128/384 Engineering Guide Console Command List
3.22  Multi-point Conference Control
COPR Request to Chairman Control 22-1
Description: Acquires or deletes chairman control.  Command is only valid when the 
VisuaLink is in a multi-point conference.
Command Format: COPR p1 p2 
p1: 1-14  :  conference room number (specified only in a NEC 
specific multi-point conference)
p2: ON :  acquire
OFF :  release
Note 1:
When p1 is omitted, it becomes a local office conference...

Page 86

Page 3-60NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
CSPR Multiple Address Transmission Request 22-2
Description: Acquires the simulcast transmission.
Command Format: CSPR p1 
p1: 0-255  :  conference room number to be received
*  :  composite screen display 
Note 1:
When p1 is omitted, it becomes a local office conference room 
number.  Also in a NEC specific multi-point conference, 1-14 
only can be specified.
Note 2:
In p1,  * is valid only when a MCU to connect has a...

Page 87

NDA-24233 Issue 2Page 3-61
VisuaLink 128/384 Engineering Guide Console Command List
CRPR Specific Picture Reception Request 22-3
CMPR Request to Switch Multiple Address Originator Monitor 22-4
Description: Activates or deactivates selective receive mode.
Command Format: CRPR p1 p2 p3
p1: 1-255  :  reception side conference room number
p2: 1-255  :  transmission side conference room number
*  :  composite screen display 
p3: ON  :  reception selection setting/ release
OFF  :  reception selection release...

Page 88

Page 3-62NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.23  Opening Control Command
OMES Opening Message at Unit Activation 23-1
Description: Report opening message at power up.  This is reported when the unit is 
automatically re-start due to some failure.  In the case of automatic reset, 
please perform necessary procedures to reconnect the line. 
Command Format: OMES p1 p2
p1: TC2000-EC : VL128
TC2000-6B : VL384
p2: F/W version (ex) V01.00.00 

Page 89

NDA-24233 Issue 2Page 3-63
VisuaLink 128/384 Engineering Guide Console Command List
3.24  Communication Status Report Command
H221 H.221 Synchronous Status Report 24-1
IMAC Manufacturer Code Report 24-2
Description: H.221 reporting status change.
Command Format: H221 p1 
p1: AI :  synchronization established
DI :  out of synchronization
Description: Reports a manufacturer code for the remote site.
Command Format: IMAC p1 p2 p3 p4 p5 OK
p1: 00-FF  : Manufacturer code  49 :  NEC
Else : other vendor
p2:...

Page 90

Page 3-64NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
IMOD Report of Common Mode in Communication 24-3
Description: Reports the negotiated mode during a communication.
Command Format: RMOD p1 p2 p3 p4 p5 p6 p7 p8 
p1: B/2B/3B/4B/5B/6B  :  communication speed
p2: 56/64 : network TYPE
p3: QCIF/FCIF  :  video format 
p4: ULW/ SBA/ LDC/ OFF  : audio mode
p5: 4.0/6.4/14.4/24.0/VMLP/OFF  : MLP speed
p6: ON/OFF  :  MBE capability
p7: ON/OFF : T120 capability
P8:...