Page 111
NDA-24233 Issue 2Page 4-1 VisuaLink 128/384 Engineering Guide Error Response Table 4: Error Response Table If a command input from console is not understandable or has a different configuration, an error response is transmitted to the console. Error responses are shown in the following table. Table 4-1: Error Response Table (1/2) ERR Number Contents Countermeasures ERR01 Syntax error. Check the format of a command ERR05 It is a command that cannot be accepted by the current system.Check current...
Page 112
Page 4-2NDA-24233 Issue 2 Error Response Table VisuaLink 128/384 Engineering Guide Figure 4-1: Error Response Table (2/2) ERR Number Contents Countermeasures ERR46 Off line. Check communication status and execute command again. ERR47 Currently processing. Try again ERR48 Disconnecting. Check communication status and execute command again. ERR49 Specified delay time is not in decimal. Check the format of command. ERR50 Specified delay time is not in 10 ms step.Check the format of command. ERR51 It...
Page 113
NDA-24233 Issue 2Page 5-1 VisuaLink 128/384 Engineering Guide Factors of Disconnections 5: List of Factors for Disconnection in Table Location of Factors for Disconnection LU: Local User LN: Local Network TN: Transit Network RU: Remote User RN: Remote Network Number Message Factors for Disconnection Countermeasure (Example) Location # 1 Unassigned numberCall cannot come in since it is currently a unassigned number. Check the remote number. LN/RU # 2 No route to specified transit networkSpecified...
Page 114
Page 5-2NDA-24233 Issue 2 Factors of Disconnections Number Message Factors for Disconnection Countermeasure (Example) Location # 50 Requested facility not subscribedProcedure for a requested facility is not taken.Contact a retailer or a service center.LN # 57 Bearer capability not authorizedUnauthorized transmission capability was requested.Contact a retailer or a service center.LN # 58 Bearer capability not presently availableTransmission capability currently not available for use.Contact a...
Page 115
NDA-24233 Issue 2Page 5-3 VisuaLink 128/384 Engineering Guide Factors of Disconnections Number Message Factors for Disconnection Countermeasure (Example) Location # 111 Protocol error, unspecifiedReport of other protocol error. After checking a remote number, retry.RN # 127 Interworking, unspecifiedInter-work occurrence in a network that cannot display a reason for operation.After checking a remote number, retry. # 901 No response from the remote terminalAutomatic Dial timed out Check a remote...
Page 117
NDA-24233 Issue 2Page A-1 VisuaLink 128/384 Engineering Guide Appendix A Appendix A: Pin-out Specification Pin-out specifications for all the VL 128/384 connectors. SERIAL 1 PORT Note: The signal direction shown is seen from the VisuaLink 128 (DTE). SERIAL 2 PORT Note: The signal direction shown is seen from the VisuaLink 128 (DTE). Headset MIC Connection (1 - 3) NO Symbol Direction Function 1 RS OUT Request to Send 2 CS IN Clear to Send 3 SD OUT Send Data 4 GND - Ground 5 RD IN Receive Data 6- - 7...
Page 118
Page A-2NDA-24233 Issue 2 Appendix A VisuaLink 128/384 Engineering Guide S/T Line (ISDN Connection) Note 1: The signal direction shown is seen from the VisuaLink 128 (DTE). Note 2: Pins 1, 2, 7, and 8 are not used. Telephone Connection S-Video Socket Input/Output PIN # Symbol Function Polarity 1a 2b 3 c Transmit Tip + 4dReceive Tip + 5 e Receive Ring - 6fTransmit Ring - 7g 8h NO Symbol Function 1 2 3 L2 2W RING PIN 4 L1 2W TIP PIN 5 6 NO PIN NAME A1 AG (Analog GND) A2 AG (Analog GND) A3 Y Signal IN...
Page 119
NDA-24233 Issue 2Page B-1 VisuaLink 128/384 Engineering Guide Appendix B Appendix B: Line Speed Specifications X : cannot set D: can set but video is not transmitting : snapshot not available X : cannot set1B (64kbps) Line Speed Audio AlgorithmsG.711 m-Law PCMG.722 SB-ADPCMG.728 LD-CELPMute Audio Byte Rate (kbps)56.048.016.00.0 MLP OFF6.4 14.4 46.462.4 MLP 4kbps2.4 10.4 42.458.4 MLP 6.4kbpsD8.0 40.056.0 MLP 14.4 kbpsXD32.0 48.0 MLP 24kbpsXX22.4 38.4 2B (128kbps) Line Speed Audio AlgorithmsG.711 m-Law...
Page 120
Page B-2NDA-24233 Issue 2 Appendix B VisuaLink 128/384 Engineering Guide This page is for your notes.