Page 51

NDA-24233 Issue 2Page 3-25
VisuaLink 128/384 Engineering Guide Console Command List
MDRD Checking Speed Dial Registration 5-4
Description: Checks the current registers speed dial number.
Command Format: MDRD p1
p1:  #xxx: speed dial number (xxx: speed number)
Response: Normal Response: p1 p2 p3 p4 p5 
OK
p1: #xxx :  speed dial number (xxx: speed number 1-130)
p2: 0-9 :  dial Number (within 20 digits)
       :  sub address (within 8 digits)
* :  address/subaddress 
**  :  Ch1/Ch2 separating code
p3: B :...

Page 52

Page 3-26NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
NBZS Setting Incoming Call Buzzer 5-6
Note: This command is ineffective when setting incoming mode is set to Automatic.  Utilize this command 
only in the Manual Answer mode.
NBZI Checking Incoming Call Buzzer Setting 5-7
Description: Sets the incoming call buzzer in a communication using BRI ISDN, this 
sets an incoming call bell to rumble when a request for a incoming call 
from a remote office is received.  This...

Page 53

NDA-24233 Issue 2Page 3-27
VisuaLink 128/384 Engineering Guide Console Command List
SINC Setting Incoming Call Mode 5-8
Description: Sets the incoming call mode.  There are three ways to receive an incoming 
call: manual incoming call mode, automatic incoming call mode, and 
selective incoming call mode.  In a manual incoming call mode, an 
operation to receive a call is required.  In an automatic incoming call mode, 
a communication starts when a request for an incoming call is received.  In 
a...

Page 54

Page 3-28NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
SRNG Setting/Checking Incoming Call Buzzer at Auto Answer Mode 5-9
SPID Registering SPID 5-10
Description:Setting ringing times of incoming call buzzer in auto answer mode or 
selective answer mode
Command Format:SRNG [p1]
 
p1: 0-9 : 0: not ringing
1-9: ringing times
Note:
  When p1 is omitted, the current setting is reported.
Response:Normal Response:
If p1 is set:  OK
If p1 is omitted:
p1 OK
p1: 0: not ringing
1-9:...

Page 55

NDA-24233 Issue 2Page 3-29
VisuaLink 128/384 Engineering Guide Console Command List
RPID Checking SPID 5-11
Description: Reporting current SPID
Command Format: RPID  p1 
p1: L11 :  Line1 Channel1
L12 :  Line1 Channel2
L21 :  Line2 Channel1
L22 :  Line2 Channel2
L31 :  Line3 Channel1
L32 :  Line3 Channel2
Response: Normal Response:  p1 p2 OK
p1:L11 :  Line1 Channel1
L12 :  Line1 Channel2
L21 :  Line2 Channel1
L22 :  Line2 Channel2
L31 :  Line3 Channel1
L32 :  Line3 Channel2
p2:SPID
Error Response:  ERR01...

Page 56

Page 3-30NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.6  Camera Related Registering/Setting Command
CPPS Registering Camera Preset Position 6-1
CPNS Registering Talker Name 6-2
Description: Registers a camera preset position.
Command Format: CPPS  p1 p2 p3 [p4]
p1: L1-2 :  Local Camera Number
R1-2 : Remote Camera Number
p2: 1-9 :  Preset Number
p3) ON :  Register
OFF : Release
p4: x ... x :  Talker Registration (alphabet 16-character)
Note 1:
  When p3 is OFF, p4 is...

Page 57

NDA-24233 Issue 2Page 3-31
VisuaLink 128/384 Engineering Guide Console Command List
SCMK Setting Camera Model 6-3
RCMK Checking Camera Model Setting 6-4
Description: Sets types of camera which will be controlled.
Command Format: SCMK  p1
p1: S : EVI-D30
C : VC-C1
Response: Normal Response: OK
Error Response:  ERR01
Description: Checks current camera control setting.
Command Format: RCMK
Response: Normal Response: p1 OK
p1: S : EVI-D30
C : VC-C1
Error Response:  ERR01  

Page 58

Page 3-32NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
3.7  Communication Status Reading Command
RMAC Read Manufacturer Code 7-1
Description: Acquires manufacturer code of a remote site.
Command Format: RMAC
Response: Normal Response: p1 p2 p3 p4 p5 OK
p1: 00-FF : Manufacturer code  49:  NEC
Else: other vendor
p2: 00-FF : Division code    00:  NEC
Else:  other division of NEC
p3: 00-FF : Unit code    01:  TC5000EX7/10
02: MMVC
03: VL128/384
10: MCU5000A
Else: Reserved
p4:...

Page 59

NDA-24233 Issue 2Page 3-33
VisuaLink 128/384 Engineering Guide Console Command List
RMOD Read Common Mode During Communication 7-2
Description: Reads negotiated parameter setting.
Command Format: RMOD
Response: Normal Response: p1 p2 p3 p4 p5 p6 p7 p8 OK
p1: 64 : 56/64 kbps
2x64 : 2x56/2x64 kbps
192 : 168/192 kbps
256 : 224/256 kbps
320 : 280/320 kbps
384 : 336/384 kbps
p2: 56 : 56 kbps network
64  :  64 kbps network
p3: QCIF/FCIF  :  video format 
p4: ULW/ SBA/ LDC/ OFF  : audio mode
p5:...

Page 60

Page 3-34NDA-24233 Issue 2
Console Command List VisuaLink 128/384 Engineering Guide
R221 Read H.221 Synchronous Status 7-3
RPNA Read Remote Site Name (at Point-to-Point) 7-4
Description: This reads a status of the H.221 frame specified in ITU-T 
Recommendation
Command Format: R221
Response: Normal Response:  p1 OK
p1: AI :  frame synchronization established
p2: DI :  frame not in synchronization
Error Response:  ERR01
ERR07
ERR42
ERR46
ERR47
ERR85
ERR87 
Description: This reads the remote site name in...