NDA-30078 Revision 1.0Page 49 UCD-XL Installation Guide Initialization and Termination Chapter 6 Initialization and Termination Initialization UCD-XL must be initialized through the APM Operations Menu according to instructions provided in the APM Operations Manual. Although each of the configured components is initialized individually, the Monitor must be initialized prior to or in conjunction with any one or more Messengers. Although the Messenger(s) cannot function unless the Monitor is already...
Page 52
Initialization and Termination UCD-XL Installation Guide Page 50NDA-30078 Revision 1.0 This Page Left Blank.
Page 53
NDA-30078 Revision 1.0Page 51 UCD-XL Installation Guide Error Messages Appendix A Error Messages Error Messages from UCD-XL Monitor The following are the error messages from UCD-XL Monitor which you might encounter in the APM log and/or on the APM screen. Immediately following each error message is a brief explanation and a possible solution to the problem. Note 1: The error code originates from UNIX. Note 2: “UDP” means User-defined Parameter. 1. Invalid option: The given input is not an...
Page 54
Page 52NDA-30078 Revision 1.0 Error Messages UCD-XL Installation Guide 8. NOT USED 9. Cannot open Group Identification Database file. (errno = ) Verify that the Group Identification Database named ucdgrps_m exists by se- lecting the “Build Master Database” option under the APMs Database Admin- istration Menu. If it does exist, use the “Process Application Database” and “Install Application Database” options in order to process and install the data- base. If not, create ucdgrps_m by following the...
Page 55
NDA-30078 Revision 1.0Page 53 UCD-XL Installation Guide Error Messages 15. No available memory. The UNIX system was unable to allocate sufficient memory to satisfy the ap- plications requirements. Additional RAM may be needed. Contact your NEC distributor or an NEC representative. 16. Cannot open a pipe to Reporter. The UNIX system was unable to create a pipe between two processes. Termi- nate all APM applications and reinitialize the Monitor. If this error occurs again, terminate OAI and exit the APM....
Page 56
Page 54NDA-30078 Revision 1.0 Error Messages UCD-XL Installation Guide 22. Connection pending for port Upon concluding an inspection of all ports, the Monitor determined that the specified port is in a state of flux. The Monitor had requested the connection of a call to that port but had not received a response from the PBX yet. Usually the port will become busy shortly after this message appears. If this message occurs for the same port during every inspection, examine a trace of call activ- ity via...
Page 57
NDA-30078 Revision 1.0Page 55 UCD-XL Installation Guide Error Messages 28. Group not defined for port The specified port belongs to a group that is not defined in the Group Identifi- cation Database (ucdgrps_m). Via the APMs Database Administration Menu, verify that the port record in the Port Assignment Database (ucdports_m) con- tains a group ID that corresponds to a record in ucdgrps_m. If either database was modified recently, make certain that it has been processed and installed. or Group not...
Page 58
Page 56NDA-30078 Revision 1.0 Error Messages UCD-XL Installation Guide 33. Release pending for port Upon concluding an inspection of all ports, the Monitor determined that the specified port is in a state of flux. The Monitor had received notice of abandon- ment by a caller, but had not received notice that the port had indeed released. Usually the port will become idle shortly after this message appears. If this message occurs for the same port during every inspection, examine a trace of call...
Page 59
NDA-30078 Revision 1.0Page 57 UCD-XL Installation Guide Error Messages 38. Duplicate pilot number for group Every group in the Group Identification Database must be assigned a unique pilot number, unless that value is 0. Via the APM’s Database Administration Menu, modify the specified record in ucdgrps_m so that its pilot number is ei- ther unique or 0. (A non-zero pilot number also must be a monitored number defined in the PBX via MAT command AMNO.) Then process and install the database again. 39....
Page 60
Page 58NDA-30078 Revision 1.0 Error Messages UCD-XL Installation Guide Error Messages from UCD-XL Messenger The following are the error messages from the UCD-XL Messenger which you might encounter in the APM log and/or on the APM screen. Immediately fol- lowing each error message is a brief explanation and a possible solution to the problem. Note: “UDP” is short for “User-defined Parameter”. 1. Monitor is not specified. UDP #1 in the Messengers configuration must specify the name of the UCD- XL...