NDA-30078 Revision 1.0Page 29 UCD-XL Installation Guide Installation Miscellaneous Set Up1. At this point, the configurations of one or more UCD-XL components have been saved, but the terminals and ports have not yet been set up to work with UCD-XL. The installation software issues the prompt I_e ]ecd RU dXU E>9H CicdU] 1T]Y^YcdbQd_b b__d d_ cUd e` dXU 1T]Y^YcdbQd_b dUb]Y^Q\ Q^T_b =39 `_bdc 9V i_e [^_g dXU b__d `Qccg_bT Q^T gYcX d_ S_^dY^eU U^dUb ´iµ+ _dXUbgYcU U^dUb ´^µ _b ´aµ d_ QR_bd dXU...
Page 33
NDA-30078 Revision 1.0Page 31 UCD-XL Installation Guide Configuring UCD-XL Chapter 3 Configuring UCD-XL This chapter provides instructions for configuring UCD-XL. You can refer to the Applications Manager (APM) Operations Manual for more information about configuring the software. Application Characteristics UCD-XL is configured into the APM system using the Add function of the Application Configuration option on the APM System Administration menu. Note:This chapter describes an alternate method for...
Page 34
Page 32NDA-30078 Revision 1.0 Configuring UCD-XL UCD-XL Installation Guide Parameter definitions: OAI Application Indicates whether or not (Yes or No) this com- ponent communicates with the NEAX2400 using OAI processes. CRT Application Indicates whether or not (Yes or No) this com- ponent runs on the same screen as the APM, rendering the APM temporarily inaccessible. Communication QueueIndicates whether or not (Yes or No) this non- OAI component needs an IPC queue to com- municate with other...
Page 35
NDA-30078 Revision 1.0Page 33 UCD-XL Installation Guide Configuring UCD-XL Initialization Batch Indicates whether or not (Yes or No) the compo- nent is to be initialized automatically when the OAI system is initialized. Termination Mode Indicates how the APM is to notify the compo- nent to terminate. Standard Output Designates the file into which component output is redirected. Number of Restarts Indicates how many times the APM may restart the component after it terminates erroneously. Queue Key...
Page 36
Page 34NDA-30078 Revision 1.0 Configuring UCD-XL UCD-XL Installation Guide Table 3-4 Monitor Parameters Parameter Entry Description Database Name #1 /oai/db/cur/ucdgrpsFilename of the UCD-XL Group Identification Database. Database Name #2 /oai/db/cur/ucdports Filename of the UCD-XL Port Assignment Database. Timeout Value #1 30Default frequency of port inspection, in minutes. This may be overridden by the value given for a group in the Group Identification Database (see page 42). If the group’s...
Page 37
NDA-30078 Revision 1.0Page 35 UCD-XL Installation Guide Configuring UCD-XL Using the OAI-Conf command on the Application Configuration Entry screen, make the entry shown for each of the following parameters required by each Messenger component; each Messenger has the same values for its parameters. Use the instructions provided for this option in the APM Operations Manual. Note:Italicized entries may be changed. User-Defined Parameters Make the entries shown for each of the following user-defined...
Page 38
Page 36NDA-30078 Revision 1.0 Configuring UCD-XL UCD-XL Installation Guide Monitor User- defined ParametersMake the following entries on the OAI Configuration screen. Italicized entries can be changed. Table 3-6 Monitor User-defined Parameters User Defined Entry Definition #1/oai/db/cur/ucdaniPathname of the ANI Pattern Database. This is required only if you desire the distribution of calls based upon their ANI data. Otherwise, leave this parameter blank. #2 (blank) This parameter is no longer...
Page 39
NDA-30078 Revision 1.0Page 37 UCD-XL Installation Guide Configuring UCD-XL Messenger User- defined ParametersMake the following entries on the OAI Configuration screen. Italicized entries can be changed. #10UCDXL_MediatorName assigned to the Mediator component. Must be as given in the Primary Configuration Parameters on page 32. #11A(ctual)Source for the mailbox number in a MCI message for a direct call to voice mail. Select one of the following entries: A(ctual): The actual line of the call....
Page 40
Page 38NDA-30078 Revision 1.0 Configuring UCD-XL UCD-XL Installation Guide Mediator User- defined ParametersMake the following entries on the APM Configuration Entry screen. Italicized entries can be changed. Table 3-8 Mediator User-defined Parameters User Defined Entry Definition #1UCDXL_MediatorName assigned to the Mediator component. Must be as listed in the Primary Configuration Parameters on page 32. #2S(tandard)MCI message set to use. Select one of the following entries: S(tandard):...