Page 41
ND-45857 (E) CHAPTER 3 Page 33 Revision 3.0 INSTALLATION STEP 2: Mount the DTI card and the DCH card in AP slots on PIM0-PIM7. After mounting the card, set the SENS switch to match an unequipped slot number in CM05. And set the MB switch to down position to put the card in service. For details on mounting locations, refer to the Circuit Card Manual. Figure 3-5 Mounting Location of DTI/DCH Card DTI/DCH CARDBUILT-IN BATTERY • Mount DTI card in the AP slots (AP0-AP6). • Mount DCH card in the AP slots...
Page 42
CHAPTER 3 ND-45857 (E) Page 34 Addendum-001 Revision 3.1 AUGUST, 1998 INSTALLATION 4.1.2 Selection of PLO in MP Card STEP 1: On the MP (PN-CP00/CP00-B/CP03) card, set the switches as shown in Figure 3-6. Figure 3-6 Switch Settings on the MP Card (1/3) RU N SW2 ON OFF 0: ON LINE MODE : POSITION TO BE SET 1 2 3 4 JP0 SW3 CLKIN JP0 RS ON: KF MODE OFF: PF/MF MODE (STANDARD SETTING FOR U.S.A.) SW1 SW2 ATTENTIONContents Static Sensitive Handling Precautions Required • PN-CP00 • WHEN USING THE...
Page 43
ND-45857 (E) CHAPTER 3 Addendum-001 Page 35 AUGUST, 1998 Revision 3.1 INSTALLATION Figure 3-6 Switch Settings on the MP Card (2/3) SW3 RUN SW1 SW2 CLKIN JP0 0: ON LINE MODE JP0 : POSITION TO BE SET • PN-CP00-B • WHEN USING THE INTERNAL PLO • WHEN USING THE PLO CARD SW2-2 SW2-3 SW2-2 SW2-3 OFF OFF : 1.5 MHz CLOCK (FOR 24-DTI)OFF ON ON OFF : 192 KHz CLOCK (FOR BRTA) OFF ON : 2 MHz CLOCK (FOR 2BRTC) ON ON : NOT USED • WHEN THE INTERNAL PLO AND THE PLO CARD ARE NOT USED SW2-2 SW2-3 OFF OFF SW2OFF ON...
Page 44
CHAPTER 3 ND-45857 (E) Page 36 Addendum-001 Revision 3.1 AUGUST, 1998 INSTALLATION Figure 3-6 Switch Settings on the MP Card (3/3) STEP 2: Mount the MP card on the MP slot of PIM0. SW2SW2 OFFON 4 3 2 1 SW3: POSITION TO BE SET : POSITION TO BE SET 0: ON LINE MODE ON: KF MODE OFF: PF/MF MODE (STANDARD SETTING FOR U.S.A.) • WHEN USING THE INTERNAL PLO SW2-2 SW2-3 OFF OFF : 1.5 MHz CLOCK (FOR 24-DTI) ON OFF : 192 KHz CLOCK (FOR BRTA) OFF ON : 2 MHz CLOCK (FOR 2BRTC) ON ON : NOT USED • WHEN...
Page 45
ND-45857 (E) CHAPTER 3 Addendum-001 Page 37 AUGUST, 1998 Revision 3.1 INSTALLATION 4.1.3 Cable Connection via the MDF for ISDN with PRI When using a twisted-pair cable, connect the cable to a CSU via the MDF as shown in Figure 3-7. Figure 3-8 shows LTC connector corresponds with the AP slots, and DTI pin assignment for each AP slot, and Figure 3-9 shows an example of the cable connection when the DTI card is mounted in the AP0 slot of PIM0. Figure 3-7 Cable Connection via the MDF for ISDN with PRI CSU...
Page 46
CHAPTER 3 ND-45857 (E) Pag e 3 8 Revision 3.0 INSTALLATION Figure 3-8 Location of the AP Slots and the LTC Connectors for DTI 126 LT061RA26RB LT12/AP2 2 27 2 TA 27 TB 328 328 429 429 530 LT075RA30RB LT13/AP3 6 31 6 TA 31 TB 732 732 833 833 934 LT089RA34RB LT14/AP4 10 35 10 TA 35 TB 11 36 11 36 12 37 12 37 13 38 LT0913 RA 38 RB LT15/AP5 14 39 14 TA 39 TB 15 40 15 40 16 41 16 41 17 RA 42 RB LT10/AP017 RA 42 RB AP6 18 TA 43 TB 18 TA 43 TB 19 44 19 44 20 45 20 45 21 RA 46 RB LT11/AP121 46 22 TA 47 TB 22...
Page 47
ND-45857 (E) CHAPTER 3 Page 39 Revision 3.0 INSTALLATION Figure 3-9 Example of Cable Connection via the MDF for DTI TO PIM0 PN-24DTA/24DTA-A RECEIVE SEND TO CSU JP MDFLT C 1 12 1 2 39 38 37 36 35 34 33 32 31 TB TA RB RA RA RB TA TB T0-31 32 33 34 AA0 BA0 AA1 BA117 42 18 4317 42 18 43 17 18 19 20RA TA42 43 44 45RB TB42 43 44 4517 18 19 20RA TA RB TB LTC1 CONNECTOR LTC (J) (P) MDF CONNECTOR AP0 [LT10]
Page 48
CHAPTER 3 ND-45857 (E) Page 40 Addendum-001 Revision 3.1 AUGUST, 1998 INSTALLATION 4.1.4 Mounting PLO Card STEP 1: On the PLO (PN-CK00) card, set the switches as shown in Figure 3-10. Figure 3-10 Switch Settings on the PLO Card STEP 2: On the MP card, set the SW2-2 to OFF and SW2-3 to ON. MB SW SYNC PLO0 PLO1 OFF ON 8 7 6 5 4 3 2 1 SW0MB : POSITION TO BE SET UP ALM DRFT ATTENTIONContents Static Sensitive Handling Pr ec autions Re quire d • SELECTION OF PLO 0 • SELECTION OF PLO 1 SW0-1 SW0-2...
Page 49
ND-45857 (E) CHAPTER 3 Page 41 Revision 3.0 INSTALLATION STEP 3: Mount the PLO (PN-CK00) card in an AP slot on PIM0 After mounting the card, set the MB switch to down position to put the card in service. For details on mounting locations, refer to the Circuit Card Manual. Figure 3-11 Mounting Location of the PLO Card PIM0 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10/AP0 LT11/AP1 LT12/AP2 LT13/AP3 LT14/AP4 LT15/AP5AP6 MP/FP/AP7BUS/AP8 PN-CK00BUILT-IN BATTERY PWR • Mount the PN-CK00 card in an...
Page 50
CHAPTER 3 ND -4 5857 ( E) IN STA LLA TION E N D CABLE CONNEC TION S E LEC TIO N OF P LO IN MOUNTI NG P LO CARD N ote : PLO ca rd (P N-CK00 ) i s r e qu ir e d when th e P B X is a ma ste r o ffic e, or wh en th e P B X r eq uir e s to int erfa ce