Page 31

ND-45857 (E) CHAPTER 3
Page 23
Revision 3.0
CHAPTER 3 INSTALLATION
1. GENERAL
This chapter details the installation procedure and work contents involved in providing ISDN to the PBX.
2. PRECAUTION IN HANDLING
The installer must wear the grounded wrist strap to protect the circuit card from static electricity, when handling
cards, and the installer must engage in the work on a grounded conductive work surface. (See Figure 3-1).
Figure 3-1   Static Electricity Precautions (1/2)
CARD FRONT
PBX
WRIST STRAP •...

Page 32

CHAPTER 3 ND-45857 (E)
Pag e 2 4
Revision 3.0
INSTALLATION
Figure 3-1  Static Electricity Precautions (2/2)
The mark shown below is attached to the sheet for the work in which circuit cards are handled. When engaging
in such work, the installer must be careful not to cause damage by static electricity.
WEAR A WRIST STRAP AND PERFORM
THE WORK ON A GROUNDED
CONDUCTIVE WORK SURFACE.
WHEN CARRYING A CIRCUIT
CARD AROUND, KEEP THE
CARD IN THE CONDUCTIVE
POLYETHYLENE BAG. CONDUCTIVE
POLYETHYLENE
BAG CIRCUIT...

Page 33

ND-45857 (E) CHAPTER 3
Page 25
Revision 3.0
INSTALLATION
CARD FRONT
PBX
NEVER TOUCH THE COMPONENTS 
OR SOLDERED SURFACE WITH 
BARE HANDS.
The installer must hold the edge of the circuit card, when plugging or unplugging the circuit card. If you touch
another area, you may be exposed to hazardous voltages.
CAUTION 

Page 34

CHAPTER 3 ND-45857 (E)
Page 26 Addendum-001
Revision 3.1 AUGUST, 1998
INSTALLATION
3. REQUIRED EQUIPMENT
3.1 Required Equipment for ISDN with PRI
Table 3-1 below shows the equipment required when providing ISDN with Primary Rate Interface to the system.
Note:PLO card (PN-CK00) is required when the PBX needs to interface with two clock supply routes with different frequen-
cies, e.g., DTI Trunk (1.544 MHz) and BRI Trunk (192 KHz or 2 MHz).
For example: T1 at 1.544 MHz, and 192 KHz or 2 MHz for BRI Trunks:...

Page 35

ND -4 5857 ( E)  CHAPTER 3
IN STA LL AT ION 

Page 36

CHAPTER 3 ND-45857 (E)
Page 28 Addendum-001
Revision 3.1 AUGUST, 1998
INSTALLATION
4. INSTALLATION PROCEDURE
4.1 Installation Procedure for ISDN with PRI
Perform the installation procedure shown in Figure 3-2.
Note:When requiring Call Recording of ISDN call, execute the installation procedure for SMDR. For details, refer to the
SMDR System Manual.
Figure 3-2   Installation Procedure for ISDN with PRI
END START
MOUNTING DTI AND
DCH CARD
SELECTION OF PLO IN
MP CARD
CABLE CONNECTION
VIA MDFSEE SECTION...

Page 37

ND -4 5857 ( E)  CHAPTER 3
IN STA LL AT ION
MB
S E NS
SW
SWO FF
S ET THE KN OB  TO  M ATCH THE  
8
JP SNEU TRA L G ROUND IN G  ON 
LINE  IM PE DAN CE:
NEU TRAL G ROUND ING ON 
J P S
JP R 0
SW -5  SW -6  SW -7  CABLE  LE NGTH
JP R 1
JP R1
JP R0
ATTE NTIO N
: P OSI TIO N  TO  BE  SET 

Page 38

CHAPTER 3 ND-45857 (E)
Pag e 3 0
Revision 3.0
INSTALLATION
Figure 3-3  Switch Settings on the DTI Card (2/2)
SEE Table 3-4
JPS JPR1
JPR0MB
SW
CRC
PCM
FRM
AIS [RMT]
RMT [AIS]
BLOFF
ON 8 
7 
6 
5 
4 
3 
2 
1
JPS
JPR0
SENS
RUN
SWMB
SET THE KNOB TO MATCH THE 
SLOT NO. (04-15) TO BE SET BY 
CM05.
: POSITION TO 
  BE SET
NEUTRAL GROUNDING ON 
THE TRANSMIT LINE:
RIGHT :  NOT PROVIDED (OPEN)
LEFT :  PROVIDED (GROUND)
NEUTRAL GROUNDING ON 
THE RECEIVE LINE:
RIGHT :  PROVIDED (GROUND)
LEFT :  NOT PROVIDED...

Page 39

ND-45857 (E) CHAPTER 3
Page 31
Revision 3.0
INSTALLATION
Table 3-4  Switch Settings for SW-1 and SW-2 on the DTI Card
DTI0 DTI1 DTI2 DTI3 DTI4
REMARKS
SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2
When only one DTI is 
providedON OFFTo send a clock signal to 
PLO0 of the MP card.
When more than one 
DTI is provided
ON OFF OFF ON OFF OFF OFF OFF OFF OFFTo send a clock signal via 
DTI1 to PLO1 of the MP/PLO 
card, when a clock signal via 
DTI0 is not supplied due to a 
transmission line failure.
(The...

Page 40

CHAPTER 3 ND-45857 (E)
Pag e 3 2
Revision 3.0
INSTALLATION
• When providing the DCH card:
Figure 3-4   Switch Settings on the DCH Card
MB
UP
SW0
ONOFF
SET THE KNOB TO MATCH 
THE AP NO. (04-15) TO BE SET 
BY CM05.SENS
: POSITION TO BE SET 4
= POSITION TO BE SET.
3
1
12345678 ON
SW1
SENS
RU N
MB
SW0
LC
LPB
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
ON
OFF: NORTHERN TELECOM INTERFACE
: AT&T INTERFACE
ON
OFF: DELETE FIRST THREE DIGITS
: NO DELETION
2
   (011) FROM INTERNATIONAL CALLS 