CHAPTER 1 ND-45670 (E)
Pag e 1 4
Revision 2.0
INTRODUCTION
Figure 1-4   DSS Console Key Numbers
00 01 02 03 04 0506
07
08 09 10 11 12 13 14 15
16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31
32 33 35 36 37 38 39
40 41 42 43 44 45 46 47
48 49 50 51 52 53
54 55 56 57 58 59
EDW-48-2
34 

Page 32

ND-45670 (E) CHAPTER 1
Page 15
Revision 2.0
INTRODUCTION
Figure 1-4  DSS Console Key Numbers (Continued)
00
06
12
18
24
30
36
42
48
54 55 56 57 58 5949 50 51 52 53 43 44 45 46 47
37 38 39 40 4131 32 33 34 35 25 26 27 28 29 19 20 21 22 23 13 14 15 16 1707 08 09 10 1101 02 03 04 05
DCU-60-1 

Page 33

CHAPTER 1 ND-45670 (E)
Pag e 1 6
Revision 2.0
INTRODUCTION
Figure 1-5   Add-On Module Key Numbers
30 31 32 33 34 35 36 37
38 39 40 41 42 43 44 45
46 47 48 49 50 51 52 53
54 55 56 57 58 59 60 61
62 63 64 65 66 67 68 69
70 71 72 73 74 75 76 77
78 79 80 81 82 83
84 85 86 87 88 89
EDW-48-2 

Page 34

ND-45670 (E) CHAPTER 1
Page 17
Revision 2.0
INTRODUCTION
Figure 1-5  Add-On Module Key Numbers (Continued)
30
36
42
48
54
60
66
72
78
84 85 86 87 88 8979 80 81 82 83 73 74 75 76 77 67 68 69 70 7161 62 63 64 65 55 56 57 58 59 49 50 51 52 53
43 44 45 46 4737 38 39 40 4131 32 33 34 35
DCU-60-1 

Page 35

CHAPTER 1 ND-45670 (E)
Pag e 1 8
Revision 2.0
INTRODUCTION
This page is for your notes. 

Page 36

ND-45670 (E) CHAPTER 2
Page 19
Revision 2.0
CHAPTER 2 FEATURE PROGRAMMING
1. GENERAL
This section provides the description for programming each service feature. 
2. DESCRIPTION OF SERVICE FEATURES
The description of each service feature comprises the following items: 
• PROGRAMMING
This section provides the procedures for programming the service feature. If the service feature is function-
ing in conjunction with other features, refer to the sections containing the information pertaining to those...

Page 37

CHAPTER 2 ND-45670 (E)
Pag e 2 0
Revision 2.0
ACCOUNT CODE
2.1 Business Features
PROGRAMMING 
HARDWARE REQUIRED 
SMDR (PN-AP00 card and cables) 
DESCRIPTION DATA
Specify whether Service Set Tone should be 
sent after dialing the access code for Account 
Code entry. (1) 362
(2) 0/1 : No Tone/Service Set Tone 
(SST)
Assign the Class of Service for Account Code 
entry to the required stations.• CM12 YY = 02
(1) X-XXXX: Primary Extension No.
(2) XX
 XX
*a: Service Restriction Class (A): 00-
15  
• CM15 YY =...

Page 38

ND-45670 (E) CHAPTER 2
Page 21
Revision 2.0
ADD-ON MODULE (1200 Series Enhancement)
PROGRAMMING
DESCRIPTION DATA
Assign the Add-On Module Number to its 
associated LEN.
Note:When the data assignment of both
DSS Console and Add-On Module
are required, the same number (the
last two digits of the data) cannot be
used.(1) 0000-0511 (LEN No.)
(2) EC00-EC31: Add-On Module No.
For PIM0/1: EC00-EC07 
For PIM2/3: EC08-EC15 
For PIM4/5: EC16-EC23 
For PIM6/7: EC24-EC31 
Assign the Multiline Terminal which will be...

Page 39

CHAPTER 2 ND-45670 (E)
Pag e 2 2
Revision 2.0
ADD-ON MODULE (1200 Series Enhancement)
PROGRAMMING
DESCRIPTION DATA
Assign the Automatic/Manual/Dial Intercom 
key to each Add-On Module, if required. For 
details, refer to INTERCOM.• YY=00
(1) Primary Extension No. + + Add-On 
Module Key No. (30-54)
(2) A000
A031 Automatic Intercom No.
A100
A131
A200
A700
A201
A701 Manual Intercom No.
A224
A724
B000
B900
B001
B901 Dial Intercom No.
B024
B924
Assign the Station Speed Dialing to the keys 
on each Add-On...

Page 40

ND-45670 (E) CHAPTER 2
Page 23
Revision 2.0
ADD-ON MODULE (1200 Series Enhancement)
HARDWARE REQUIRED
DSS Console
PN-2DLC/4DLC Card (Two or four DSS Console can be accommodated per card)
DESCRIPTION DATA
Assign the Day/Night Key on each Add-On 
Module, if required.• YY=00
(1) Primary Extension No. + + Add-On 
Module Key No. (87-89)
(2) F0043: Day/Night Key
Specify the tone ringer enabled on call 
termination to each line/trunk key on each 
Add-On Module, if required.• YY=01
(1) Primary Extension No. + +...