    							NDA-24213 CHAPTER 4
    Page 37
    Issue 3.0
    Programming the PBX and the Dterm
    Programming the Dterm Series III ACD Terminal
    8. Programming the D
    term Series III ACD Terminal
    Figure 4-2   D
    term Series III ACD Terminal
    8.1 Programming the Keys
    Use CM90 YY= 00 and the functions listed to program Keys 17 through 24.
    Key 17 = F1020 Release
    Key 18 = F1033 Break (OAI Key 1, CMD7 Y=0, OP-Code 187)
    Key 19 = F1042 Log On (OAI Key 10, CMD7 Y=0, OP-Code 190)
    Key 20 = F1039 Tally (OAI Key 7, CMD7 Y=0, OP-Code 189)
    Key 21 = F1036 Work (OAI Key 4, CMD7 Y=0 OP-Code 253)
    Key 22 = F1012 Conference
    Key 23 = F1004 Transfer
    Key 24 = F1010 Hold
    1
    (01)(02)(03)(04)
    (07)(08)(09)(10)
    (13)(14)(15)(16)
    (32)(33)(34)(35)
    23
    456
    789
    *0#
    (17)
    Release
    (18)
    Break
    (19)
    Logon
    (20)
    Ta l l y
    (21)
    Work
    (22)
    Conf
    (23)
    Transfer
    (24)
    HoldETJ-24DS-1Multiline Terminal Key Number
    (05)
    (11)
    (30)
    (36)
    (06)
    (12)
    (31)
    (37) 
    						
    							CHAPTER 4 NDA-24213
    Page 38
    Issue 3.0
    Programming the PBX and the Dterm
    Programming the Dterm Series III ACD Terminal
    All other ACD function keys will be programmed on Keys 1 through 16.
    8.2 Service Conditions
    1. In order for Logon (Key 19) and Break (Key 18) to chime, a speaker key must be assigned to a 
    Key number between 1-16.
    2. The FNC (F1011), Recall (1015), LNR/SPD (F1000), and Answer (F4001) Keys can be assigned to 
    Keys 1-16.
    3. Do not use the MAT command F2, “Copy of D
    term Key”, if your ACD terminals are a mixture of 
    Series III and Series E sets. The key layouts are different between these two terminals. You can copy 
    from Series E to Series E, and from Series III to Series III, but you cannot copy from Series E to 
    Series III.
    4. If the first port (level 0) of the card is set to a 1 (Elite) in CM12 YY=17, a PN-4DLCA or PN-4DLCM 
    card must be installed. If you use a PN-4DLCD card with the first port (level 0) set to a 1 (Elite) in 
    CM12 YY=17, the ACD Keys will not function and there is no display on the terminal.
    5. D
    term series ACD terminals are supported with Series 1800 software CJ0.17 and above. 
    						
    							NDA-24213 CHAPTER 5
         Page 39
    Issue 3.0
    Configuration Procedures
    CHAPTER 5 Configuration Procedures
    The basic options available for configuring common setups using CallCenterWorX are diagrammed below. 
    Figure 5-1   Configuration Options
    This chapter provides procedures for configuring the components to perform in the above setups.
    Main CCWX PC
    using CCWX ACD portion only
     (Server and MAT Client )
    without MIS
    MIS PC using CCWX
    MIS portion only
    TCP/IPRS-232
    Main CCWX PC
    using CCWX complete suite
     ACD (Server and MAT Client)
    with MIS
    MIS PC using CCWX
    MIS portion only
    TCP/IPRS-232
    MIS PC using CCWX
    MIS portion only
    MIS PC using CCWX
    MIS portion only
    OR
    OR 
    						
    							CHAPTER 5 NDA-24213
    Page 40     
    Issue 3.0
    Configuration Procedures
    Figure 5-2   ACD Computer (Client or Server) With or Without MIS
    Suite installation
    complete
    Verify all system
    requirements available
    (Chapter 2)Complete connections
    (Chapter 3)Complete programming
    PBX and Dterms(Chapter 4)
    Assemble information
    (Chapter 6)
    Install complete
    CallCenterWorX  suite
    (Chapter 6)Install CallCenterWorX
    ACD only
    (Chapter 6)
    Start
    CallCenterWorX
    ACD
    (Chapter 6)
    Read ACD menu and
    command
    descriptions
    (Chapter 7)
    Program ACD
    system
    (Chapter 9)
    For complete suite,
    read MIS menu and
    command
    descriptions
    (Chapter 8)
    Perform initial
    startup  of MIS
    (Chapter 10)
    ACD only
    installation
    complete
    Install appropriate
     Security Key if needed
    (Chapter 6) 
    						
    							NDA-24213 CHAPTER 5
         Page 41
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    1. Configuring the ACD Computers
    1.1 ACD Computer (Client or Server) With or Without MIS
    For the ACD computer (Client or Server) with or without MIS, use the following procedure:
    STEP 1: Verify that the system requirements specified in Table 2-1 of Chapter 2 are available.
    STEP 2: Depending upon your PBX hardware, complete the connections described in Chapter 3, Heading 1, 
    “Installing the PN-CC00 and the PN-AP01” (illustrated in Figure 3-1and Figure 3-2), or in
    Heading 2, “Installing the PN-CC01 and the PN-AP01” (illustrated in Figure 3-3).
    STEP 3: Complete the procedures in Chapter 4, “Programming the PBX and the D
    term.”
    STEP 4: Follow the procedures in Chapter 6, Heading 1, “Security Key Installation Instructions.” 
    If you wish to run the 
    ACD Server and MAT Client option on this computer, with or without the 
    MIS application, install a CallCenterWorX Version 2 Security Key. 
    If you wish to run 
    only the ACD MAT Client option on this computer, no Security Key is required.
    If you wish to run the 
    ACD MAT Client and the MIS application on this computer, an MIS 
    Security Key is required.
    STEP  5:  Read Chapter 6, Heading 2, “Installation Information Needed,” and assemble the information needed 
    for installing CallCenterWorX.
    STEP 6: Choose one of the following:
    If you wish to run 
    both the ACD and MIS portions of the program on this computer, install the 
    complete CallCenterWorX suite by following the procedures in Chapter 6, Heading 3, 
    “CallCenterWorX CD-ROM Installation Instructions.” Please note that the remote MIS PC to be 
    configured later is not a client to the server MIS installation; all MIS databases are independent.
    If you wish to run 
    only the ACD portion of the program on this computer, install only the 
    CallCenterWorX ACD program (either the MAT Client option or the Server and MAT Client 
    option) by following the procedures in Chapter 6, Heading 3, “CallCenterWorX CD-ROM 
    Installation Instructions.” 
    STEP 7: Follow the procedures in Heading 4, “Starting CallCenterWorX ACD,” in Chapter 6.
    STEP 8: Program the ACD system as described in Chapter 9, “ACD Procedures.” Information on the menu 
    commands and data screens can be found in Chapter 7, “ACD Menu Commands.”
    STEP 9: If you installed only a CallCenterWorX ACD option (MAT Client or Server and MAT Client) in 
    Step 6, the procedure is complete.
    STEP 10: If you installed the complete CallCenterWorX suite with MIS in Step 6:
    (a) Follow the procedures in Chapter 10, Heading 1, “CallCenterWorX MIS Initial Setup.”
    (b) Close the CallCenterWorX MIS–Setup window. 
    						
    							CHAPTER 5 NDA-24213
    Page 42     
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    Figure 5-3   ACD Computer Setup for Use with Remote MIS PC via TCP/IP
    Read MIS menu and
    command
    descriptions
    (Chapter 8)
    Perform initial
    startup of  MIS
    choosing TCP/IP
    (Chapter 10)
    Installation
    complete
    Close MIS
    systemIf needed,
    complete MIS PC
    setup for TCP/IP
    (Heading 2.1)
    Verify all system
    requirements available
    (Chapter 2)Complete connections
    (Chapter 3)
    Install CallCenterWorX
    Version 2 Security Key
    (Chapter 6)Assemble information
    (Chapter 6)
    Install complete
    CallCenter
    WorX  suite
    or
    ACD Server and MAT Client
    (Chapter 6)Start
    CallCenter
    WorX
    ACD
    (Chapter 6)
    Read ACD menu and
    command
    descriptions
    (Chapter 7)
    Program ACD
    system
    (Chapter 9)Close ACD
    system
    Complete programming
    PBX and Dterms
    (Chapter 4) 
    						
    							NDA-24213 CHAPTER 5
         Page 43
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    1.2 ACD Computer Setup for Use with Remote MIS PC via TCP/IP
    For the ACD computer communicating with a remote MIS PC via TCP/IP, use the following procedure: 
    STEP 1: Verify that the system requirements specified in Table 2-2 of Chapter 2 are available.
    STEP 2: Depending upon your PBX hardware, complete the connections described in Chapter 3, Heading 3, 
    “PN-CC00 Connecting Through a Hub” (shown in Figure 3-4 and Figure 3-5), or in Chapter 3, 
    Heading 4, “PN-CC01 Connecting Through a Hub” (shown in Figure 3-6).
    STEP 3: Complete the procedures in Chapter 4, “Programming the PBX and the D
    term.”
    STEP 4: Following the procedures in Chapter 6, Heading 1, “Security Key Installation Instructions,” install a 
    CallCenterWorX Version 2 Security Key. 
    STEP  5: Read Chapter 6, Heading 2, “Installation Information Needed,” and assemble the information needed 
    for installing CallCenterWorX.
    STEP 6: Following the procedures in Chapter 6, Heading 3, “CallCenterWorX CD-ROM Installation 
    Instructions,” install either:
    The complete CallCenterWo r X suite, choosing ACD Server and MAT Client plus CallCenterWo r X 
    MIS. Please note that the remote MIS PC to be configured later is not a client to the server MIS 
    installation; all MIS databases are independent.
    The CallCenterWo r X ACD Server and MAT Client only. 
    STEP 7: Follow the procedures in “Starting CallCenterWorX ACD” in Chapter 6, Heading 4.
    STEP 8: Program the ACD system as described in Chapter 9, “ACD Procedures.” Information on the menu 
    commands and data screens can be found in Chapter 7, “ACD Menu Commands.”
    STEP 9: On the 
    Server menu, click MAT, then click Disconnect.
    STEP 10: Click 
    Exit on the File menu to close the CallCenterWorX ACD system.
    STEP  11: If CallCenterWorX MIS is loaded, open the MIS following the procedures in Chapter 10, Heading 1,  
    “CallCenterWorX MIS Initial Setup.” and follow the procedures for the Communication Type 
    TCP/IP.
    STEP 12: Close the CallCenterWorX 
    MIS–Setup window.
    STEP 13: If not already completed, go to Heading 2.1, “MIS PC Setup for Use via TCP/IP” in this chapter and 
    complete all steps. 
    						
    							CHAPTER 5 NDA-24213
    Page 44     
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    Figure 5-4   ACD Computer Setup for Use with Remote MIS PC via RS-232
    Read MIS menu and
    command
    descriptions
    (Chapter 8)
    Perform initial
    startup  of MIS
    choosing RS-232
    (Chapter 10)
    Close MIS
    system
    Start
    CallCenter
    WorX
    ACD
    (Chapter 6)
    Read ACD menu and
    command
    descriptions
    (Chapter 7)
    Program ACD
    system
    (Chapter 9)
    Installation
    complete
    Close ACD
    system
    If needed,
    complete MIS PC
    setup for RS-232
    (Heading 2.2)
    Set ACD
     Tenant Data
    I/O Ports for MIS
    (Chapter 9)Set ACD
    Communication
    Data I/O Ports for
    MIS
    (Chapter 9)
    Verify all system
    requirements available
    (Chapter 2)Complete connections
    (Chapter 3)Complete programming
    PBX and Dterms
    (Chapter 4)
    Install CallCenter
    WorX
    Version 2 Security Key
    (Chapter 6)Assemble information
    (Chapter 6)
    Install complete
    CallCenter
    WorX  suite
    or
    ACD Server and MAT
    Client
    (Chapter 6) 
    						
    							NDA-24213 CHAPTER 5
         Page 45
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    1.3 ACD Computer Setup for Use with Remote MIS PC via RS-232
    For the ACD computer communicating with a remote MIS PC via serial RS-232 connection, use the 
    following procedure:
    STEP 1: Verify that the system requirements specified in Table 2-3 of Chapter 2 are available.
    STEP 2: Depending upon your PBX hardware, complete the connections described in Chapter 3, Heading 5, 
    “PN-CC00 Connection for ACD Computer to Remote MIS PC Serially” (shown in Figure 3-7), or in 
    Chapter 3, Heading 6, “PN-CC01 Connection for ACD Computer to Remote MIS PC Serially” 
    (shown in Figure 3-8).
    STEP 3: Complete the procedures in Chapter 4, “Programming the PBX and the D
    term.”
    STEP 4: Following the procedures in Chapter 6, Heading 1, “Security Key Installation Instructions,” install a 
    CallCenterWorX Version 2 Security Key.
    STEP  5: Read Chapter 6, Heading 2, “Installation Information Needed,” and assemble the information needed 
    for installing CallCenterWorX.
    STEP 6: Following the procedures in Chapter 6, Heading 3, “CallCenterWorX CD-ROM Installation 
    Instructions,” install either:
    The complete CallCenterWo r X suite, choosing ACD Server and MAT Client plus CallCenterWo r X 
    MIS. Please note that the remote MIS PC to be configured later is not a client to the server MIS 
    installation; all MIS databases are independent.
    The CallCenterWo r X ACD Server and MAT Client only. 
    STEP 7: Follow the procedures in Heading 4, “Starting CallCenterWorX ACD,” in Chapter 6.
    STEP 8:  Program the ACD system as described in Chapter 9, “ACD Procedures.” Information on the menu 
    commands and data screens can be found in Chapter 7, “ACD Menu Commands.”
    STEP 9: Access the ACD Tenant Data dialog by selecting the 
    Tenant Data command from the MAT menu or 
    selecting the 
    Tenant icon on the console Toolbar.
    STEP 10: When the Tenant Data dialog displays, in the area marked “I/O Port Assignment” you will find tabs 
    marked COM1 and COM2. On each tab are buttons to select “OFF” or to select “MIS” (which enables 
    you to set that communication port to send and receive MIS data for this tenant). Select the 
    appropriate port (
    COM1 or COM2) and click the button marked MIS.
    STEP 11: Click 
    Update to enter your selection into the system data. The Status Bar display informs you that 
    the system data has been updated. 
    STEP 12: Click 
    Close to exit the dialog.
    STEP 13: Access the ACD Communications Data dialog by selecting 
    Communications Data from the MAT 
    menu
    , or by selecting the Communications icon on the console Toolbar.
    STEP 14: When the Communication Data dialog displays, in the area marked “I/O Ports” are two areas labeled 
    “Port 1” and “Port 2” showing port type. Select the same port you specified in Step 10 above (
    COM1 
    or COM2) and click the MIS-2 option.
    STEP 15: Click 
    Update to enter this into the system data. The Status Bar display informs you that the system 
    data has been updated. 
    						
    							CHAPTER 5 NDA-24213
    Page 46     
    Issue 3.0
    Configuration Procedures
    Configuring the ACD Computers
    STEP 16: Click Close to exit the dialog.
    STEP 17: On the 
    Server menu, click MAT, then click Disconnect.
    STEP 18: Click 
    Exit on the File menu to close the CallCenterWorX ACD system.
    STEP 19: If the MIS was installed, read the information on the menu commands and data screens in Chapter 8, 
    “MIS Menu Commands.” 
    STEP  20: Perform the initial startup of the MIS system as described in Chapter 10, “MIS Procedures,” choosing 
    the 
    Communication Type RS-232 and setting the COM Port to agree with the port chosen in 
    Step 10: and Step 14: above.
    STEP 21: Close the CallCenterWorX MIS–Setup window.
    STEP 22: If needed, complete the setup for the remote MIS PC using RS-232 (see this chapter, Heading 2.2).
    Figure 5-5   MIS PC Setup for Use via TCP/IP
    Verify all system
    requirements available
    (Chapter 2)Complete connections
    (Chapter 3)Complete programming
    PBX and Dterms
    (Chapter 4)
    Install MIS
    Security Key
    (Chapter 6)Assemble information
    (Chapter 6)
    Install only
    CallCenter
    WorX  MIS
    (Chapter 6)
    Read MIS menu and
    command
    descriptions
    (Chapter 8)
    Perform initial
    startup of  MIS
    choosing TCP/IP
    (Chapter 10)
    Installation
    complete
    Close MIS
    system 
    						