NDA-24213 CHAPTER 2
Page 17
Issue 3.0
System Requirements
CallCenterWorX MIS PC Support
7. CallCenterWorX MIS PC Support
7.1 Multiple MIS PCs
CallCenterWorX provides the ability to have up to eight MIS PCs. 
The integrated MIS application on the main CallCenterWorX Server is controlled by the main 
CallCenterWorX system security key and is counted as one of the eight PCs.
Each additional MIS PC requires a separate MIS security key.
It is important to know that each additional MIS PC is a separate MIS...

Page 32

CHAPTER 2 NDA-24213
Page 18
Issue 3.0
System Requirements
Multi-tenant MIS Considerations—Split Numbering
8. Multi-tenant MIS Considerations—Split Numbering
The assignment of split numbers in the CallCenterWorX MIS is relative to the number of tenants being served 
by the entire system (which can be as many as 9 tenants). A single MIS application can number only one usable 
Split 1 in the system. It does not employ the naming conventions used by the ACD, which starts numbering for 
each tenant at Split 1...

Page 33

NDA-24213 CHAPTER 3
Page 19
Issue 3.0
Connection Drawings
Installing the PN-CC00 and the PN-AP01
CHAPTER 3 Connection Drawings
Figure 3-1   PN-CC00 Connection through 10 Base T Transceiver
1. Installing the PN-CC00 and the PN-AP01
STEP 1: Mount the PN-CC00 in any slots LT10 (AP0) - LT15 (AP05). The PN-CC00 requires two LT (AP) 
slots.
STEP 2: Mount the PN-AP01 in any slot LT10 (AP0) - LT15 (AP05).
STEP 3: Set the PN-AP01 SENSE 0 switch to the slot number that is programmed in CM05 (see Chapter 4,...

Page 34

CHAPTER 3 NDA-24213
Page 20
Issue 3.0
Connection Drawings
Installing the PN-CC01 and the PN-AP01
2. Installing the PN-CC01 and the PN-AP01
Figure 3-3   PN-CC01 Connection Straight to ACD Computer (Client or Server)
STEP 1: Mount the PN-CC01 in any slots LT10 (AP0) - LT15 (AP05). The PN-CC01 requires one LT (AP) 
slot.
STEP 2: Mount the PN-AP01 in any slot LT10 (AP0) - LT15 (AP05).
STEP 3: Set the PN-AP01 SENSE 0 switch to the slot number that is programmed in CM05 (see Chapter 4, 
Heading 1, “AP01...

Page 35

NDA-24213 CHAPTER 3
Page 21
Issue 3.0
Connection Drawings
PN-CC00 Connecting Through a Hub
3. PN-CC00 Connecting Through a Hub
Figure 3-4   PN-CC00 Connecting Through a Hub
STEP 1: The Ethernet cables going from the transceiver to the hub and from the hub to the Server and PCs are 
straight-through cables.
STEP 2: The Ethernet cable from the transceiver to the hub goes into a port other than Port 8 of an 8-port hub 
or Port 4 of a 4-port hub. The last port in a hub is usually used as an uplink port,...

Page 36

CHAPTER 3 NDA-24213
Page 22
Issue 3.0
Connection Drawings
PN-CC01 Connecting Through a Hub
4. PN-CC01 Connecting Through a Hub
Figure 3-6   PN-CC01 Connecting Through a Hub
STEP 1: The Ethernet cables going to the hub from the PN-CC01 and from the hub to the Server and PCs are 
straight-through cables.
STEP 2: The Ethernet cable from the transceiver to the hub goes into a port other than Port 8 of an 8-port hub 
or Port 4 of a 4-port hub. The last port in a hub is usually used as an uplink port,...

Page 37

NDA-24213 CHAPTER 3
Page 23
Issue 3.0
Connection Drawings
PN-CC00 Connection for ACD Computer to Remote MIS PC Serially
5. PN-CC00 Connection for ACD Computer to Remote MIS PC Serially
Figure 3-7   PN-CC00 with RS-232 Serial Connection
Note:
In this diagram, it is assumed the remote PC is using CallCenterWorX MIS.
STEP 1: Follow the procedures in this chapter, Heading 1, “Installing the PN-CC00 and the PN-AP01,” to 
connect the PN-CC00 to the ACD computer.
STEP 2: Connect one end of the RS-232 serial...

Page 38

CHAPTER 3 NDA-24213
Page 24
Issue 3.0
Connection Drawings
PN-CC01 Connection for ACD Computer to Remote MIS PC Serially
6. PN-CC01 Connection for ACD Computer to Remote MIS PC Serially
Figure 3-8   PN-CC01 Connection for ACD Computer to Remote MIS PC Serially
Note:
In this diagram, it is assumed the remote PC is using CallCenterWorX MIS.
STEP 1: Follow the procedures in this chapter, Heading 2, “Installing the PN-CC01 and the PN-AP01,” to 
connect the PN-CC01 to the ACD computer .
STEP 2: Connect one end...

Page 39

NDA-24213 CHAPTER 3
Page 25
Issue 3.0
Connection Drawings
Connecting Wall Display Boards
7. Connecting Wall Display Boards
Connections from the computer running CallCenterWorX MIS to the Spectrum Wall Display Board may vary 
according to the specific model of board. Instructions should be obtained from Spectrum Corporation
regarding the model you are installing.
The computer must be configured to output data to the board through a COM Port.
Wall boards may be used in a “chained” series following...

Page 40

CHAPTER 3 NDA-24213
Page 26
Issue 3.0
Connection Drawings
Connecting Wall Display Boards
Figure 3-10   PN-CC01 Connecting ACD Computer or MIS PC to Wall Boards
As shown in Figure 3-11 below, the RS-232 Cable connects to the COM Port designated as an MIS Port (see 
Chapter 5, Heading 1.3, “ACD Computer Setup for Use with Remote MIS PC via RS-232”).
Figure 3-11   Connection of RS-232 to COM Port
 
NEAX2000 IVS
PN-CC01
PN-AP01Ethernet Cable
CallCenterWorX ComputerCOM Port
RS-232 CableWallboards
NEC Customer...