Page 111

CHAPTER 3 NDA-24301
Pag e 9 4
Revision 1.0
7. Switch Setting Sheet
SWITCH NAME SWITCH SHAPE REMARKS
MB
SW01
SW02
1234 56 78ON
1234 56 78ON 

Page 112

NDA-24301 CHAPTER 4
Page 95
Revision 1.0
CHAPTER 4 OFFICE DATA ASSIGNMENT
This chapter explains the office data assignment for the System. Refer to the “Feature Programming Manual” for
basic office data assignment for the PBX and other programming for service features. Sections 1 and 2 of this chapter
provide guidelines to the system data and the programming of ZT and PS office data as a basic data assignment,
while Section 3 provides information regarding each service data assignment.
1. BASIC OFFICE...

Page 113

CHAPTER 4 NDA-24301
Pag e 9 6
Revision 1.0
OFFICE DATA ASSIGNMENT
1.2 ZT OFFICE DATA ASSIGNMENT
 CSINT circuit card can accommodate a maximum of four ZTs.
 Every ZT has three speech channels in the form of 3B+D.
 Each ZT is provided with PHS Community, Calling Area, Group and ZT number, given a maximum
capacity to have 32 areas while each area has eight groups. One group can house 32 ZTs.
PHS Community: PHS community having the same SYS-ID is identified by PHS community Number
(PCN).
Calling Area:...

Page 114

NDA-24301 CHAPTER 4
Page 97
Revision 1.0
OFFICE DATA ASSIGNMENT
1. ZT Initial Start-Up
1) ASYD (Assignment of System Data)
CCIS ISDN function simultaneously becomes valid when the ZT operation is attempted to be in 
service, as the ZT is regarded as a terminal of the ISDN.
SYS1
SI186 
Note 1
b6=1 (CCIS function in service)
SI220 
Note 1
b6=0 (ISDN function in service)
Note 1:ISDN and CCIS data become valid, but where the ISDN and CCIS functions are not to be
used, optional software concerning ISDN and...

Page 115

CHAPTER 4 NDA-24301
Pag e 9 8
Revision 1.0
OFFICE DATA ASSIGNMENT
2.  Add Operating ZT
1) Installation of Additional ZT
2) Call LVP Server system
3) ALVPL (Assignment of LVP Code for Local Data Memory)
KIND=1
Assign the LVP Code
ACSDL (Assignment of CS/ZT Data for Local Data Memory)
This command is used to assign the ZT related data including the PHS Community Number, 
Calling Area No., Group No., ZT No., ZT LENS, ZT KIND.
When this data assignment is finished, 3B+D channels of the CSINT circuit card...

Page 116

NDA-24301 CHAPTER 4
Page 99
Revision 1.0
OFFICE DATA ASSIGNMENT
3. ZT Deletion Procedure
1) MBCSL (MAKE BUSY of CS/ZT for Local Data Memory)
2) ACSDL (Assignment of CS/ZT Data for Local Data Memory)
Delete the ZT Data.
 START
 END 

Page 117

CHAPTER 4 NDA-24301
Pag e 1 00
Revision 1.0
OFFICE DATA ASSIGNMENT
1.3 PS OFFICE DATA ASSIGNMENT
Below are explanations about assigning office data by which the PS can be in operation in the Built-in PCS
system.

The port is automatically occupied for each PS assignment from the bigger numbered port (MG=31,U=3, G=23,
Level=7) to the smaller. When adding UNIT to the system later, you must concern about the number of assigned
PS (for example, if 192 PSs are assigned, the biggest numbered UNIT can not be...

Page 118

NDA-24301 CHAPTER 4
Page 101
Revision 1.0
OFFICE DATA ASSIGNMENT
3. Deletion of the PS data
1) ALGSL (Assignment of Telephone Number Data for Local Data Memory)
Delete the related Telephone Number and LENS.
2) APSD (Assignment of the PS Operation Data for DM)
Using this command, delete the PS data to be cleared such as tenant No., station No., SFC and 
RSC.
 END
 START 

Page 119

CHAPTER 4 NDA-24301
Pag e 1 02
Revision 1.0
OFFICE DATA ASSIGNMENT
2. BASIC OFFICE DATA ASSIGNMENT (FUSION)
2.1 SYSTEM DATA
The following data assignment is necessary for activating the PCS service.
Note:For more detail about the above data, refer to the ASYD command in Chapter 5. ASYD-SYS1
SI30=06
SI420
b0: Access code using the Pre-Set dialing
0/1: Out/In service (Normal Setting=0)
SI421
SI422
SI423:  AUTOMATIC ANNOUNCEMENT-PS OUT OF ZONE disconnection timer
: No tone connection timer to the called...

Page 120

NDA-24301 CHAPTER 4
Page 103
Revision 1.0
OFFICE DATA ASSIGNMENT
2.2 ZT OFFICE DATA ASSIGNMENT
 CSINT circuit card can accommodate a maximum of four ZTs.
 Every ZT has three speech channels in the form of 3B+D.
 Each ZT is provided with PHS Community, Calling Area, Group and ZT number, given a maximum
capacity to have 32 areas while each area has eight groups. One group can house 32 ZTs.
PHS Community: PHS community having the same SYS-ID is identified by PHS community Number
(PCN).
Calling Area:...