NEC Neax 2400 Ipx Hotel Office Data Specification
Here you can view all the pages of manual NEC Neax 2400 Ipx Hotel Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 71
NDA-24315 CHAPTER 4 Page 59 Issue 1 AHSY: Assignment of Hotel System Parameter 101 b0LANG = 0Incoming calls terminating to the Attendant Console from a guest station of the language category correspond to each bit. The key to which the call terminates: 0: GST1 Key 1: GST2 Key Language data is assigned to each guest station based on information from the PMS. b1LANG = 1 b2LANG = 2 b3LANG = 3 b4LANG = 4 b5LANG = 5 b6LANG = 6 b7LANG = 7 102 b0LANG = 8When an incoming call terminates to the Attendant...
Page 72
CHAPTER 4 NDA-24315 Page 60 Issue 1 AHSY: Assignment of Hotel System Parameter — AHSY INDEX 105 b7 — Display Pattern A: b7 = 0 (For Interface Type Model 60/90/120) Display Pattern B: b7 = 1 (For Interface Type Model 90/120) 105 0b0Not used0b1 b2 Maid Dial service from Attendant Console 0/1 = Not Required/Required 0b3 Office Name Display on Attendant Console assigned at AOFC command or ASYD command SYS 1, INDEX 96 through 115. 0/1 = In/Out of Service b4 Pattern of Wake-Up Time Indication on the Attendant...
Page 73
NDA-24315 CHAPTER 4 Page 61 Issue 1 AHSY: Assignment of Hotel System Parameter Display Pattern when “0” is assigned in b7 Note:b7 = 0: When PMS Model 60/90/120. b7 = 1: When PMS Model 90, 120. INDEX(0 – 1023) DATA (DATA)00 – FF(Hex) BIT CORRESPONDINGDATACONTENTS DATA0/1BIT 107 b0Display Pattern for termination b1b0b1b0 00=Pattern 1 10 01=Pattern 2 11Designation of Display Pattern of D term (Special Administration Station) for Guest Name Display D term service. b1 b2Display Pattern for call...
Page 74
CHAPTER 4 NDA-24315 Page 62 Issue 1 AHSY: Assignment of Hotel System Parameter INDEX(0 – 1023) DATA(DATA)00 – FF (Hex) BITCORRESPONDINGDATACONTENTS DATA 0/1BIT 108 b0Display Change Timer for the Display Pattern of the Answering station (assigned INDEX 107 b 4 and b5) 0 Hex: Standard Timer Value = 8 to 10 sec. 1 Hex ~ F Hex: Timer Value = (1–15) × 1 sec. b1 b2 b3 b4Display Change Timer for the Display Pattern of the Originating station (assigned INDEX 107 b3 and b2) 0 Hex: Standard Timer Value = 2–4...
Page 75
NDA-24315 CHAPTER 4 Page 63 Issue 1 AHSY: Assignment of Hotel System Parameter 110 b0 Room key Interface 0 : Interface is absent (STAY/OUT is displayed) 1 : Interface is present (Key status is displayed) b1 Attendant Console Guest Information Service 0/1 = Not Required/Required 0b2Not used b3 Called Number Display on the Attendant Console 0/1 = Out/In Service 0b4 Not used0b5 0b6 b7 Guest Name Display – Dterm, Guest Information Display – Dterm/PMS Terminal Model 120 0/1 = Out/In Service 111 0b0Fixed...
Page 76
CHAPTER 4 NDA-24315 Page 64 Issue 1 AHSY: Assignment of Hotel System Parameter 11200 b0 Not used b1 b2 b3 b4 b5 Wake-Up - Head Start Operation 0/1 = Out/In Service b6Not usedb7 11300Not used 114 0b0 Not used 0b1 0b2 0b3 0b4 b5 Hotel Console key designation 0/1 = Depending on SYS-1, INDEX 160, Bits 3 and 4 (ASYD)/PI 115-126 (AHSY) 0b6Not used b7 Consecutive Dialing from Attendant Console (for service such as VMM) 0/1 = Not Required/Required If “1” (Required) is assigned, switch settings for the ATI card...
Page 77
NDA-24315 CHAPTER 4 Page 65 Issue 1 AHSY: Assignment of Hotel System Parameter 115Attendant Console Key Data 116 117 118 119 120 121 122 123 124 125 126 12700Not used 12800Not used 12900Not used 13000Not used 13100Not used 13200Not used 13300Not used 13400Not used 13500Not used 13600Not used 13700Not used 13800Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 121 122 123 124 125 126789 111210 115 116 117 118 119 120123 564 INDEX INDEXOperation Key Operation...
Page 78
CHAPTER 4 NDA-24315 Page 66 Issue 1 AHSY: Assignment of Hotel System Parameter 139 0b0Not used0b1 b2 MW Lamp Indication of “Do Not Disturb” 0/1 = Lights Steadily/Flashes b3 MW Lamp Indication of “Do Not Disturb” 0/1 - Not Required/Required b4 MW Lamp Indication of “Message Waiting” 0/1 = Lights Steadily/Flashes b5 MW Lamp Indication of “Message Waiting” 0/1 = Not Required/Required b6 2-Line Guest Name Display on a Dterm 0/1 = Out/In Service 0b7Not used 14000Not used 14100Not used 14200 b0 b1 b2 b3 b4Wa k...
Page 79
NDA-24315 CHAPTER 4 Page 67 Issue 1 AHSY: Assignment of Hotel System Parameter 150 b0b2b1b0b2b1b0 000=–100=Model 120 001=–101=– 010=Model 60 110=– 011=Model 90 111=– b1 b2 0b3~b7Not used 15100 Not used 15200 15300 15400 15500 15600 15700 15800 15900 16000 16100 16200 163 b0 2nd Wake-Up Call Service 0/1 = Out/In Service b1 2nd Wake-Up Call Timer Indication on Hotel Console 0/1 = Out/In Service b2 2nd Wake-Up Call Cancel while Hotel Console is connected to the target station 0/1 = Out/In Service b3Not...
Page 80
CHAPTER 4 NDA-24315 Page 68 Issue 1 AHSY: Assignment of Hotel System Parameter 165 b0EQP Type for Maid Status (0~15) 0: EQP16 1~F: EQP1~EQP15 b1 b2 b3 b4 Tone Type when Maid Status “To be cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b5 Tone Type when Maid Status “Cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b6 Tone Type when Maid Status “Ready for Occupancy” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5,...