Page 81

NDA-24315 CHAPTER 4
Page 69
Issue 1
AHSY: Assignment of Hotel System Parameter
179
b0
Not usedb1
b2
b3
b4Designation of Guest Access Code
b7b6b5b4ACC - CODEb7b6b5b4ACC - CODE
0000 Out of Service 0111 7
0001 1 1000 8
0010 2 1001 9
0011 3 1010 0
0100 4 1011 *
0101 5 1100 #
0110 6
b5
b6
b7
18000Not used
18100Not used
182
0b0Not used
b1
Called # printout (Alert Service)                                    
0/1 = No/Yes
b2
When a guest station has been called out by Alert Service, if that guest station 
is...

Page 82

CHAPTER 4 NDA-24315
Page 70
Issue 1
AHSY: Assignment of Hotel System Parameter
183
b0Setting of Attendant Console that sets Alert Service
0 Hex: Service can be set from any of the Attendant Consoles
1 - F Hex: Service can be set only from the Attendant Console of the 
designated Console Number 
b1
b2
b3
b4
Classifying the call termination indicating keys based on the Language 
category of the guest at the time an incoming call from the guest station 
terminated to the Attendant Console.
0/1 = Not...

Page 83

NDA-24315 CHAPTER 4
Page 71
Issue 1
AHSY: Assignment of Hotel System Parameter
185
0b0Not used
b1
Guest Room Calling - Attendant Console Service
0/1 = Out/In Service
0b2
Not used
0b3
0b4
0b5
0b6
0b7
186
b0
Not used
b1
b2
b3
b4
b5
b6
b7
Double Suite Room Service
0/1 = Out/In Service
187
0b0Not used0b1
b2
Processing for the case where there is any busy station among the Suite Room 
stations generally called by Suite Room Calling - Attendant Console service
0/1 = Sending Busy Tone/Idle Station Calling
0b3...

Page 84

CHAPTER 4 NDA-24315
Page 72
Issue 1
AHSY: Assignment of Hotel System Parameter
188
b0Processing for Suite Room Station/Connecting Room Station Busy
b1b0
0 0 : Busy Tone
0 1 : An idle station within the room is called
1 0 : From a station, the call is transferred to the Attendant Console if the 
caller is not the console operator.
b1
0b2Fixed Data0b3
0b4Not used
b5
When a call terminates to the Double Suite Room:
0/1 = All stations ring simultaneously/Alternately between Primary Suite and 
Secondary...

Page 85

NDA-24315 CHAPTER 4
Page 73
Issue 1
AHSY: Assignment of Hotel System Parameter
19100Not used
19200Not used
19300Not used
19400Not used
19500Not used
19600Not used
19700Not used
19800Not used
19900Not used
20000Not used
20100Not used
20200Not used
20300Not used
20400Not used
20500Not used
20600Not used
20700Not used
20800Not used
20900Not used
21000Not used
21100Not used
21200Not used
21300Not used
21400Not used
21500Not used
21600Not used
21700Not used
21800Not used
21900Not used
22000Not used
22100Not...

Page 86

CHAPTER 4 NDA-24315
Page 74
Issue 1
AHSY: Assignment of Hotel System Parameter
22600Not used
22700Not used
22800Not used
22900Not used
23000Not used
23100Not used
23200Not used
23300Not used
23400Not used
23500Not used
23600Not used
23700Not used
23800Not used
23900Not used
24000Not used
24100Not used
24200Not used
24300Not used
24400Not used
245 00Not used
24600Not used
24700Not used
24800Not used
24900Not used
25000Not used
25100Not used
252b0
Room Key Information
0/1 = Key Rack Type/Card Rack Type...

Page 87

NDA-24315 CHAPTER 4
Page 75
Issue 1
AHSY: Assignment of Hotel System Parameter
258
0b0Not used
b1
Maid Status - Cleaning Start via Guest Station
(Feature Code = 11, Function Code = 1)
Sending Service Feature 
Text (Information) to PMS
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit.
b2
Maid Status - Cleaning End via Guest Station
(Feature Code = 11, Function Code = 2)
b3
Maid Status - Inspection End via Guest Station
(Feature Code = 11,...

Page 88

CHAPTER 4 NDA-24315
Page 76
Issue 1
AHSY: Assignment of Hotel System Parameter
262
0b0
Not used
Sending Service Feature 
Text (Information) to PMS
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit.
0b1
0b2
b3
Message Waiting Lamp - On
(Feature Code = 13, Function Code = 3)
b4
Message Waiting Lamp - Off
(Feature Code = 13, Function Code = 4)
0b5
Not used0b6
0b7
26300Not used
264
0b0Not used
Sending Service Feature 
Text (Information) to PMS...

Page 89

NDA-24315 CHAPTER 4
Page 77
Issue 1
AHSY: Assignment of Hotel System Parameter
266
0b0Not used
Sending a Service Feature 
Text (Information) to PMS.
0/1 = In Service/Out 
Service
When the text is not to be 
sent to PMS, “1” assigned to 
the corresponding bit.
0b1
b2
Room Cutoff and Do Not Disturb
(Feature Code = 15, Function Code = 2)
b3
Not used
0b4
0b5
0b6
0b7
26700Not used
268
0b0
Not used0b1
0b2
0b3
b4
Checkout - C.O. line Outgoing Call Report
(Feature Code = 16, Function Code = 5)
b5
Checkout -...

Page 90

CHAPTER 4 NDA-24315
Page 78
Issue 1
AHSY: Assignment of Hotel System Parameter
270
0b0Not used
Sending a Service Feature 
Text (Information) to PMS
0/1 = In Service/Out of 
Service
When the text is not to be 
sent to PMS, “1” is assigned 
to the corresponding bit.
0b1
b2
Room Data Image - Room Data Report
(Feature Code = 17, Function Code = 2)
0b3Not used
b4
Room Data Image - Room Data Exchange
(Feature Code = 17, Function Code = 4)
0b5Not used
b6
Room Data Image - Room Data Report
(Feature Code = 17,...