Home > NEC > Communications System > NEC Neax 2400 Ipx Hotel Office Data Specification

NEC Neax 2400 Ipx Hotel Office Data Specification

Here you can view all the pages of manual NEC Neax 2400 Ipx Hotel Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 41

NDA-24315 CHAPTER 2
Page 29
Issue 1
ASSIGNMENT
Figure 2-22   Network Control Data Assignment Flow Chart (2/2)
TrunkATRKMBTKAMATASATATGLAAKP
ATRKMBTK
Service
CCIS No. 7
ISDN
ASHPASHCASHUAUCDAUOGAUADACPGACPE
AISAAISDASGDASIDACFSASLU1ASLU2
ACSAACSIANCDATASAEKDAANDAANDE
ASPDAATCACFO
ARPCARDN
ACDDACNPACNDAFCPACBCAVTCAVTL
ACNPNACNDN
AEVT
Internal TrunkATT
External TrunkORT / IRT / SND / CFT:ACOC
APAD
AAED
ADPC
ADPCACSC
ACSC
AAEDL
ACIC1
ACIC1
ARTI
ACIC2
ARTDATRKMBTKPSTN         :
TIE LINE   :       
DAT...

Page 42

CHAPTER 2 NDA-24315
Page 30
Issue 1
ASSIGNMENT
3. Hotel Command
Figure 2-23   Hotel Command Data Assignment Flow Chart (1/2)
Figure 2-23   Hotel Command Data Assignment Flow Chart (2/2)
ASYD System BaseASYDLAHSYAUNTAIOCAPSWATIMASTDAOFC
AUIDN
AASTAASNAPHNANDDAKYD
RAST
AACL
Sys1 Index512 - 1535
Sys1 Index0 - 511 ,  Sys2 Index0  - 15 & Sys3 Index0 - 31
Numbering Plan
Network Numbering
Restriction
Station Number
Trunk:        Same as the Business Command
Service         :
STA - STA     :
Day / Night     :...

Page 43

NDA-24315 CHAPTER 3
Page 31
Issue 1
CHAPTER 3 OFFICE DATA DESIGN SHEET
Office data design sheets are used to design the configuration and specification of IPX.
1. Trunking Diagram
The Trunking diagram shows the system configuration and the number of lines.
2. Bay Face Layout
The Bay Face layout shows the circuit card mounting slots.
3. Port Location Table
A Port Location table denotes the Line/Trunk circuit cards located in each Universal Slot of PIM.
4. Numbering Plan Table
Area Codes for various...

Page 44

CHAPTER 3 NDA-24315
Page 32
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-1   Trunking Diagram
PFT
LC MDF
DLC/ELC
DLC
DTL
COT
COT
COT
DID
EMT
DID
TLT
DTI
RST
MFCT
DTI
CCHMODEM
DTI (PRI)
DCH
ATI
RGU
HWU
LTST
1
HUB
TO MAT
CCH
PRINTER ATT/DESK CONSOLE
IOCCPROSC/PLO
MAINTENANCE
ADMINISTRATION
TERMINAL (MAT)
SUBSCRIBER
D
termW/O DATA ADAPTER
DtermWITH DATA ADAPTER
FROM/TO
CENTRAL OFFICE
FROM/TO TIE LINE
FROM/TO CCIS LINE
FROM/TO ISDN LINE
(PRI) 
 
Note: Table 3-1 identifies the function name of each circuit card....

Page 45

NDA-24315 CHAPTER 3
Page 33
Issue 1
OFFICE DATA DESIGN SHEET
Table 3-1 identifies the function name of each circuit card used for the system.
Table 3-1 Circuit Card Function Name
SYMBOLDESCRIPTION
AT IAttendant Console Interface
BWTBothway Trunk
CCHCommon Channel Handler
CFTConference Trunk
COTCentral Office Trunk
CPRCentral Processing Rack
DCHD Channel Handler
DIDDirect Inward Dialing
DITDirect-In Termination
DLCDigital Line Circuit
DODDirect Outward Dialing
DtermDigital Multi-Function Telephone...

Page 46

CHAPTER 3 NDA-24315
Page 34
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-2   Card Mounting Slot
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
PH-SW10 (TSW) PH-SW10 (TSW)
PIM3
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A (PWR0)PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
PIM2
00  01   02  03  04  05  06   07  08   09  10  11   12...

Page 47

NDA-24315 CHAPTER 3
Page 35
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-3   Card Mounting Slot for 4-IMG System (1/4)
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PH-PC36(MUX) PH-PC36(MUX)
PIM3
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PIM2
00  01   02  03  04  05  06   07  08   09...

Page 48

CHAPTER 3 NDA-24315
Page 36
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-3   Card Mounting Slot for 4-IMG System (2/4)
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PH-PC36(MUX) PH-PC36(MUX)
PIM3
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PIM2
00  01   02  03  04  05  06   07  08   09...

Page 49

NDA-24315 CHAPTER 3
Page 37
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-3   Card Mounting Slot for 4-IMG System (3/4)
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PH-PC36(MUX) PH-PC36(MUX)
PIM3
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PIM2
00  01   02  03  04  05  06   07  08   09...

Page 50

CHAPTER 3 NDA-24315
Page 38
Issue 1
OFFICE DATA DESIGN SHEET
Figure 3-3   Card Mounting Slot for 4-IMG System (4/4)
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PH-PC36(MUX) PH-PC36(MUX)
PIM3
00  01   02  03  04  05  06   07  08   09  10  11   12  13  14  15   16  17  18  19   20  21  22   23PA-PW55-A(PWR0)PA-PW54-A(PWR1)PH-PC36(MUX) PH-PC36(MUX)
PIM2
00  01   02  03  04  05  06   07  08   09...