NDA-24315 CHAPTER 2
Page 9
Issue 1
ASSIGNMENT
5. The dialog box, shown in Figure 2-8 (information on WINSOCK setup), appears. Click OK.
Figure 2-8   Winsock 2 Setup Message Dialog Box
6. File copy starts automatically, while the displayed dialog boxes (See Figure 2-9) show the on-going
situation.
Figure 2-9   IPX MAT Installation Screen
7. If the Setup Complete dialog box appears on the screen, the file copies have finished successfully. Click
Finish to complete the IPX MAT software installation and...

Page 22

CHAPTER 2 NDA-24315
Page 10
Issue 1
ASSIGNMENT
Note:You should always reboot your PC after installing the IPX MAT software. Any change made during the in-
stallation process does not take effect until the computer has been rebooted.
Figure 2-10   IPX MAT Setup Complete Dialog 

Page 23

NDA-24315 CHAPTER 2
 Page 11
Issue 1
ASSIGNMENT
8. Review the settings you have chosen, and then click Next. The Winsock2 Setup message box displays.
Note:If you are installing IPX MAT on an NT 4.0 workstation, the Winsock2 Setup message box does not display.
NT 4.0 does not require Winsock2 in order to run.
Figure 2-11   IPX MAT Installing Winsock2 Message Box
9. After Winsock2 is installed, the Winsock2 Setup dialog box displays. This is an informational message
only. Click OK to continue installing...

Page 24

CHAPTER 2 NDA-24315
Page 12
Issue 1
ASSIGNMENT
11. Click Next. The Select Components dialog box displays.
Figure 2-14   DAO Select Components Screen
12. Uncheck the ODBCDirect box and click Next. The Select Components dialog box displays.
Note:If you do not uncheck the ODBCDirect box, error messages display once the DAO Setup program
completes. IPX MAT will run properly even though these messages display.
Figure 2-15   Select Components Screen 

Page 25

NDA-24315 CHAPTER 2
 Page 13
Issue 1
ASSIGNMENT
13. Click Next. The DAO Setup Screen displays.
Figure 2-16   DAO Setup Screen
14. After the DAO files are installed, the DAO Information message box displays. Click OK. The IPX MAT
Installation screen displays.
Figure 2-17   DAO Information Message 

Page 26

CHAPTER 2 NDA-24315
Page 14
Issue 1
ASSIGNMENT
15. To run the IPX MAT software, click the IPX MAT icon on the desktop or select it from the Start/Program
menu. The IPX MAT menu displays as shown in Figure 2-18.
Figure 2-18   IPX MAT Main Menu
16. To configure the PBX Alias, use the instructions in Section 6.2, TCP/IP Connection.
Note:Once you have configured the IPX MAT, you can use the Run Command line to enter task commands, or
you can select the command from the Command Folders. You can also perform...

Page 27

NDA-24315 CHAPTER 2
Page 15
Issue 1
ASSIGNMENT
5. IPX MAT Commands
The IPX MAT’s operation is very similar to that of the NEAX2400 MS-DOS MAT, so you will find that many
of the key stroke operations have been carried over into IPX MAT. In addition, some standard MS Windows
operations and key strokes are used. Use the following keys, or in some instances the mouse, to select or enter
data.
6. Configuring IPX MAT
This section explains the PBX Alias parameters you may configure using the PBX Administration...

Page 28

CHAPTER 2 NDA-24315
Page 16
Issue 1
ASSIGNMENT
6.1 Serial/Direct Connection
The following steps explain how to configure the PBX Alias for a serial/direct connection using the
recommended default data.
Note 1:The PBX Alias cannot have spaces in the name.
Note 2:You can use other data when configuring IPX MAT. However, it is recommended that you use the default
data as previously described when configuring a new PBX Alias.
Table 2-3 PBX Administration Default Values
PBX AliasNEAX-IPX
Connection...

Page 29

NDA-24315 CHAPTER 2
Page 17
Issue 1
ASSIGNMENT
1. From the PBX menu, select Configuration to open the PBX Administration dialog box.
Figure 2-20   PBX Administration
2. Enter a name for the PBX Alias in the PBX Alias box.
Note:You can also define a PBX Alias by selecting the default NEXT-IPX or by modifying any other previously
defined Alias from the list in the PBX Alias box. If you select a PBX Alias from the list, its related
information displays in the additional fields on this dialog box. You can...

Page 30

CHAPTER 2 NDA-24315
Page 18
Issue 1
ASSIGNMENT
14. Click Add to write the data.
15. Click Close.
Note:The PBX Administration dialog box changes adapting to EX-FCCS Network. Enter the Fusion Group
Number (FUG) which the PBX to be logged-in belongs. “Connection Timeout”, “Response Timeout”, and
“Pacing Timer” text box is not provided. Others are the same as previous one. The PBX dialog box is as
shown below.
6.2 TCP/IP Connection
This section explains how to add or modify a PBX Alias in IPX MAT when it is...