NDA-24315 CHAPTER 4 Page 79 Issue 1 AHSY: Assignment of Hotel System Parameter 274 0b0Not used Sending a Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b1 Automatic Wake-Up is set (Feature Code = 19, Function Code = 1) b2 Automatic Wake-Up is canceled (Feature Code = 19, Function Code = 2) b3 Automatic Wake-Up Result (Feature Code = 19, Function Code = 3) 0b4Not used0b5 b6 Automatic Wake-Up...
Page 92
CHAPTER 4 NDA-24315 Page 80 Issue 1 AHSY: Assignment of Hotel System Parameter 28400Not used 28500Not used 28600Not used 28700Not used 28800Not used 28900Not used 29000Not used 29100Not used 292 0b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b1 Check-In via a Dterm (Feature Code = 46, Function Code = 1) 0b2Not used b3 Bill Inquiry via a Dterm (Feature Code = 46, Function Code...
Page 93
NDA-24315 CHAPTER 4 Page 81 Issue 1 AHSY: Assignment of Hotel System Parameter 302 b0Not used b1 Maid Status - Guest Room 1 (Feature Code = 51, Function Code = 1) Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. Note:These Texts are used for Maid Status Answer Back System. b2 Maid Status - Guest Room 2 (Feature Code = 51, Function Code = 2) b3 Maid Status - Guest Room 3 (Feature Code...
Page 94
CHAPTER 4 NDA-24315 Page 82 Issue 1 AHSY: Assignment of Hotel System Parameter 306 b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. b1 b2 Message Waiting Lamp On via a Dterm (Feature Code = 53, Function Code = 2) b3 Message Waiting Lamp On via a Dterm (Feature Code = 53, Function Code = 3) b4 Not usedb5 b6 b7 30700 308 0b0Not used b1 Call Detail Data (Feature Code = 54,...
Page 95
NDA-24315 CHAPTER 4 Page 83 Issue 1 AHSY: Assignment of Hotel System Parameter 312 0b0 Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is no to be sent to PMS, “1” is assigned to the corresponding bit. 0b1 0b2 0b3 0b4 0b5 0b6 b7 Provisional Check-In (Feature Code = 56, Function Code = 7) 313 b0 Provisional Checkout (Feature Code = 56, Function Code = 8) b1 Checkout Message Waiting Report (Feature Code = 56, Function Code = 9) 0b2 Not used 0b3...
Page 96
CHAPTER 4 NDA-24315 Page 84 Issue 1 AHSY: Assignment of Hotel System Parameter 324 0b0Not used Sending Service Feature Text (Information) to PMS 0/1 = In Service/Out of Service When the text is not to be sent to PMS, “1” is assigned to the corresponding bit. 0b1 b2 Guest Room Secretary Telephone Setting/ Cancellation (Feature Code = 62, Function Code = 2) 0b3 Not used 0b4 0b5 0b6 0b7 32500Not used 32600Not used 32700Not used 32800Not used 32900Not used 33000Not used 33100Not used 33200Not used...
Page 97
NDA-24315 CHAPTER 4 Page 85 Issue 1 AHSY: Assignment of Hotel System Parameter 35000Not used 35100Not used 35200Not used 35300Not used 35400Not used 35500Not used 35600Not used 35700Not used 35800Not used 35900Not used 360 b0 Digits Code 0 Outgoing Call Access Code No. 1 Note:When the dial access code contains “0,” enter “A” for “0.” Example:When the dial access code is “9- 202”. b1 b2 b3 b4 Digits Code 1b5 b6 b7 361 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 INDEX (0 – 1023)DATA (DATA) 00 –...
Page 98
CHAPTER 4 NDA-24315 Page 86 Issue 1 AHSY: Assignment of Hotel System Parameter 362 b0 Digits Code 0 Outgoing Call Access Code No. 2 Note:When the dial access code contains “0,” enter “A” for “0.” Example:When the dial access code is “9- 202”. b1 b2 b3 b4 Digits Code 1b5 b6 b7 363 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 364 b0 Digits Code 0 Outgoing Call Access Code No. 3 Note:When the dial access code contains “0,” enter “A” for “0.” Example:When the dial access code is “9- 202”....
Page 99
NDA-24315 CHAPTER 4 Page 87 Issue 1 AHSY: Assignment of Hotel System Parameter 366 b0 Digits Code 0 Outgoing Call Access Code No. 4 Note:When the dial access code contains “0,” enter “A” for “0.” Example:When the dial access code is “9- 202”. b1 b2 b3 b4 Digits Code 1b5 b6 b7 367 b0 Digits Code 2b1 b2 b3 b4 Digits Code 3b5 b6 b7 36800Not used 36900Not used 37000Not used 37100Not used 37200b0~b7Not used 37500b0~b7Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA...
Page 100
CHAPTER 4 NDA-24315 Page 88 Issue 1 AHSY: Assignment of Hotel System Parameter 376 0b0Not used Text sent to PMS printout 0/1 = Not Required/ Required If “1” assigned to the corresponding bit, the text is output to the Hotel printer. Note:When a failure occurs in a data link between the NEAX2400 IPX and the PMS, the error information is printed. b1Maid Status - Guest (Feature Code = 11) b2Maid Status - Admin. (Feature Code = 12) b3 Message Waiting Lamp (Feature Code = 13) 0b4Not used b5 Room Cut...