NDA-24315 CHAPTER 4 Page 59 Issue 1 AHSY: Assignment of Hotel System Parameter 101 b0LANG = 0Incoming calls terminating to the Attendant Console from a guest station of the language category correspond to each bit. The key to which the call terminates: 0: GST1 Key 1: GST2 Key Language data is assigned to each guest station based on information from the PMS. b1LANG = 1 b2LANG = 2 b3LANG = 3 b4LANG = 4 b5LANG = 5 b6LANG = 6 b7LANG = 7 102 b0LANG = 8When an incoming call terminates to the Attendant Console from a guest station of the language category corresponding to each bit. The key to which the call terminates: 0: GST1 Key 1: GST2 Key Language data is assigned on each guest station basis as per the information from the PMS. b1LANG = 9 b2LANG = 10 b3LANG = 11 b4LANG = 12 b5LANG = 13 b6LANG = 14 b7LANG = 15 103Tenant Number of Paging Console (2~63/255 = 02~FF Hex) 104 b0 Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0–15). Paging Console Auto- matic Recall Timer: Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, ROM data is automatically set to 3 min. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the fol- lowing values: b6b5b4b6b5b4 000=–100=64 sec. 001=8 sec. 101=– 010=16 sec. 110=– 011=32 sec. 111=– b5 b6 b7 Paging Console Automatic Recall Timer value 0/1 = Ineffective/Effective INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24315 Page 60 Issue 1 AHSY: Assignment of Hotel System Parameter — AHSY INDEX 105 b7 — Display Pattern A: b7 = 0 (For Interface Type Model 60/90/120) Display Pattern B: b7 = 1 (For Interface Type Model 90/120) 105 0b0Not used0b1 b2 Maid Dial service from Attendant Console 0/1 = Not Required/Required 0b3 Office Name Display on Attendant Console assigned at AOFC command or ASYD command SYS 1, INDEX 96 through 115. 0/1 = In/Out of Service b4 Pattern of Wake-Up Time Indication on the Attendant Console 0/1 = 24-Hour/12-Hour System 0b5Not used0b6 b7 Guest Name Display on Attendant Console 0/1 = Interface Type Model 60, 90, 120/Model 90, 120 10600Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 567891011121314151617181920 1234 Guest Name Display Area (15 characters) SPACE SPACE SPACE Wake-Up Time (4 characters)Language (4 characters)Room Class (3 characters) Room Status (4 characters) Station Number (Max. 6 digits) 567891011121314151617181920 1234 Guest Name Display Area (16 characters) SPACE SPACE Station Number (Max. 6 digits)Wake-Up Time Option Data (8 characters)Room Status (3 characters)
NDA-24315 CHAPTER 4 Page 61 Issue 1 AHSY: Assignment of Hotel System Parameter Display Pattern when “0” is assigned in b7 Note:b7 = 0: When PMS Model 60/90/120. b7 = 1: When PMS Model 90, 120. INDEX(0 – 1023) DATA (DATA)00 – FF(Hex) BIT CORRESPONDINGDATACONTENTS DATA0/1BIT 107 b0Display Pattern for termination b1b0b1b0 00=Pattern 1 10 01=Pattern 2 11Designation of Display Pattern of D term (Special Administration Station) for Guest Name Display D term service. b1 b2Display Pattern for call origination b3b2b3b2 0001=Pattern 5 11 10=Pattern 6 b3 b4Display Pattern for answering a call, or the caller an- swers a call originated by Dterm. b5b4 b5b4 0001=Pattern 8 01 11=Pattern 9 b5 b6Tenant of Dterm that displays Guest Name 0/1 = All Tenants/Only Tenant No. 1 b7Guest Name Display on Dterm 1: Display pattern is determined as per the contents of b0 through b6 Option A and B 0: VIP and LANGNote = Pattern 3 = Pattern 4 = Pattern 7 ×× GUEST NAME (a) ×× GUEST NAME (b) ××× × × STATION NUMBER Guest Name is displayed first: (pattern (a)) and after a predetermined timing the pattern is automatically changed to pattern (b). ROOM STATUS
CHAPTER 4 NDA-24315 Page 62 Issue 1 AHSY: Assignment of Hotel System Parameter INDEX(0 – 1023) DATA(DATA)00 – FF (Hex) BITCORRESPONDINGDATACONTENTS DATA 0/1BIT 108 b0Display Change Timer for the Display Pattern of the Answering station (assigned INDEX 107 b 4 and b5) 0 Hex: Standard Timer Value = 8 to 10 sec. 1 Hex ~ F Hex: Timer Value = (1–15) × 1 sec. b1 b2 b3 b4Display Change Timer for the Display Pattern of the Originating station (assigned INDEX 107 b3 and b2) 0 Hex: Standard Timer Value = 2–4 sec. 1 Hex ~ F Hex: Timer Value = (1–15) × 1 sec. b5 b6 b7 109 0b0Not used b1 Charging Method of Attendant Console (If No. 7 CCIS service is provided, “1” must be assigned) 0 = 9 + Trunk Number 1 = Specific Attendant Number b2 When Admin. or GST STA dials the unused number of the Dead level number 0/1 = –/ The call is transferred to the Hotel Console automatically b3Not used b4 Emergency Call Monitor 0/1 = Out/In Service b5 Busy Status Display – Hotel Attendant Console 0/1 = Out/In Service b6 Front Desk Terminal (FDT) function keys 0/1 = Fixed/Flexible 0b7Not used
NDA-24315 CHAPTER 4 Page 63 Issue 1 AHSY: Assignment of Hotel System Parameter 110 b0 Room key Interface 0 : Interface is absent (STAY/OUT is displayed) 1 : Interface is present (Key status is displayed) b1 Attendant Console Guest Information Service 0/1 = Not Required/Required 0b2Not used b3 Called Number Display on the Attendant Console 0/1 = Out/In Service 0b4 Not used0b5 0b6 b7 Guest Name Display – Dterm, Guest Information Display – Dterm/PMS Terminal Model 120 0/1 = Out/In Service 111 0b0Fixed Data0b1 b2 Restriction for hooking when an outgoing C.O. line call has originated from a suite room 0/1 = Restriction/No Restriction b3 Setting of Message Registration Data to be sent out to the PMS b4b3 0 0 : The pilot number is sent out for the Suite Room; the Main Room Station Number is sent out for the Connecting Room. 0 1 : The Station Number of each station within the room is sent out.b4 0b5Fixed Data0b6 b7 Connecting Room 0/1 = Out/In Service INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24315 Page 64 Issue 1 AHSY: Assignment of Hotel System Parameter 11200 b0 Not used b1 b2 b3 b4 b5 Wake-Up - Head Start Operation 0/1 = Out/In Service b6Not usedb7 11300Not used 114 0b0 Not used 0b1 0b2 0b3 0b4 b5 Hotel Console key designation 0/1 = Depending on SYS-1, INDEX 160, Bits 3 and 4 (ASYD)/PI 115-126 (AHSY) 0b6Not used b7 Consecutive Dialing from Attendant Console (for service such as VMM) 0/1 = Not Required/Required If “1” (Required) is assigned, switch settings for the ATI card are necessary. INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24315 CHAPTER 4 Page 65 Issue 1 AHSY: Assignment of Hotel System Parameter 115Attendant Console Key Data 116 117 118 119 120 121 122 123 124 125 126 12700Not used 12800Not used 12900Not used 13000Not used 13100Not used 13200Not used 13300Not used 13400Not used 13500Not used 13600Not used 13700Not used 13800Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT 121 122 123 124 125 126789 111210 115 116 117 118 119 120123 564 INDEX INDEXOperation Key Operation Key ENT CE END 81H— —WU SET 91H— —CHECK IN 82H— —WU RESET 92H— —CHECKOUT 83H— —MW SET 93H— —— — 84H— —MW RESET 94H— —— — 85H— —DD SET 95H— —C.O. CHANGE 86H— —DD RESET 96H— —BOSS/SEC ENT 87H— —RC SET 97H— —BOSS/SEC RESET 88H— —RC RESET 98H— —— — 89H— —STATUS 99H— —— — 8AH— —AUDIT 9AH— —— — 8BH— —— —9BH— —— — 8CH— —— —9CH— —— — 8DH— —— —9DH— —— — 8EH— —— —9EH— —— — 8FH— —— —9FH— —GRP DND RESET 90H— —— —A0H— —GRP RESTRICTION SET A1H— —GRP RESTRICTION RESET
CHAPTER 4 NDA-24315 Page 66 Issue 1 AHSY: Assignment of Hotel System Parameter 139 0b0Not used0b1 b2 MW Lamp Indication of “Do Not Disturb” 0/1 = Lights Steadily/Flashes b3 MW Lamp Indication of “Do Not Disturb” 0/1 - Not Required/Required b4 MW Lamp Indication of “Message Waiting” 0/1 = Lights Steadily/Flashes b5 MW Lamp Indication of “Message Waiting” 0/1 = Not Required/Required b6 2-Line Guest Name Display on a Dterm 0/1 = Out/In Service 0b7Not used 14000Not used 14100Not used 14200 b0 b1 b2 b3 b4Wa k e - U p C a l l “Busy” Condition: Transfer to Attendant b5Wa k e - U p C a l l “Don’t Answer” Condition: Transfer to Attendant b6Wa k e - U p C a l l “Block” Condition: Transfer to Attendant b7Wa k e - U p C a l l “Busy/Block” Condition: Transfer to Attendant 14300Not used 14400Not used 14500Not used 14600Not used 14700Not used14800 149b0 Hotel service in CCIS No. 7 0/1 = Out/In Service b1~b7Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
NDA-24315 CHAPTER 4 Page 67 Issue 1 AHSY: Assignment of Hotel System Parameter 150 b0b2b1b0b2b1b0 000=–100=Model 120 001=–101=– 010=Model 60 110=– 011=Model 90 111=– b1 b2 0b3~b7Not used 15100 Not used 15200 15300 15400 15500 15600 15700 15800 15900 16000 16100 16200 163 b0 2nd Wake-Up Call Service 0/1 = Out/In Service b1 2nd Wake-Up Call Timer Indication on Hotel Console 0/1 = Out/In Service b2 2nd Wake-Up Call Cancel while Hotel Console is connected to the target station 0/1 = Out/In Service b3Not used b4The number of calls for Automatic Wake-Up at the same time (per LP) b5b4b5b4 00=512 Calls 10=128 Calls 01= 64 Calls 11=256 Calls b5 b6The number or Retry when a Wake-Up Call encounters busy status. b7b6b7b6 00=3 times 10=Once 01=Twice 11=No Retry b7 16400Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24315 Page 68 Issue 1 AHSY: Assignment of Hotel System Parameter 165 b0EQP Type for Maid Status (0~15) 0: EQP16 1~F: EQP1~EQP15 b1 b2 b3 b4 Tone Type when Maid Status “To be cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b5 Tone Type when Maid Status “Cleaned” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST b6 Tone Type when Maid Status “Ready for Occupancy” has been set: 0/1 = Tone designated in ASYD (SYS-1 INDEX 163, b5, b6)/SST 0b7Not used 166 b0TN = 2Whether “C.O. Incoming Call Answer Station Manual Change” service is provided or not is set on the basis of each TN (Tenant) corresponding to each bit. 0/1 = Out/In Service b1TN = 3 b2TN = 4 b3TN = 5 b4TN = 6 b5TN = 7 0b6Not used0b7 16700Not used 16800Not used 16900Not used 17000Not used 17100Not used 17200Not used 17300Not used 17400Not used 17500Not used 17600Not used 17700Not used 17800Not used INDEX (0 – 1023)DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA CONTENTS DATA 0/1BIT