    							NDA-24315 CHAPTER 4
    Page 249
    Issue 1
    AHSU: Assignment of Suite Room Station Number
    AHSU: Assignment of Suite Room Station Number
    1. General
    When the system provides Suite Room Service and/or Double Suite Room Service, this command assigns a
    specific guest station as a suite room station.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. Before assigning Suite Room Service or Double Suite Room Service, ensure the system data in AHSY
    command, INDEX=187, 188, 189 has been properly assigned.
    3. The station to be assigned as a suite room station must have already been assigned as a guest room.
    4. A phantom number can be assigned to the primary guest station of a suite room.
    5. Branch stations are not included in the number of suite room stations. 
    6. The primary guest station of a suite room must be assigned without exception. 
    						
    							CHAPTER 4 NDA-24315
    Page 250
    Issue 1
    AHSU: Assignment of Suite Room Station Number
    3. Data Entry Instructions
    TENANT NUMBER (TN)
    TYPE
       
    PHANTOM
        NUMBER
      (PHANTOM)
    MAX. 6 DIGITS SUITE ROOM PRIMARY
                  STATION
           (PRIMARY STN)         SUITE ROOM
             SECONDARY
               STATION 1
      (SECONDARY STN 1)        SUITE ROOM
            SECONDARY
              STATION 2
      (SECONDARY STN 2)        SUITE ROOM
            SECONDARY
              STATION 3
      (SECONDARY STN 3)
    PHANTOM
    SECONDARY 1/2/3
    PRIMARY STATION NUMBER 1  (PRIMARY STN 1) PRIMARY STATION NUMBER 2  (PRIMARY STN 2)
    PRIMARY STN 1PRIMARY STN 2
    Primary station number
    of Primary Suite Room  Primary station number
    of Secondary Suite RoomWhen phantom number is not assigned, enter return key.
    When secondary number is not assigned, enter return key. 0 = Single Suite Room
    1 = Double Suite Room Note
    Note:    When assigning Double Suite Room, Single Suite Room data assignment is necessary in advance.
    When TYPE=0 (Single Suite Room)
    When TYPE = 1 (Double Suite Room)
    STATION NUMBER (STN)       TYPE (TYPE) 0/1 
    						
    							NDA-24315 CHAPTER 4
    Page 251
    Issue 1
    AHSU: Assignment of Suite Room Station Number
    4. Data Sheet
    (a) When TYPE = 0 (Single Suite Room)
    TENANT
    NUMBER(TN)
    TYPE
    (TYPE) 0/1
    STATION
    NUMBER(STN)
    PHANTOM
     NUMBER(PHANTOM)Max. 6 DIGITS
    SUITE ROOM
    PRIMARYSTATION(PRIMARY)
    SUITE ROOMSECONDARYSTATION 1
    (SECONDARY 
    STN 1)
    SUITE ROOMSECONDARYSTATION 2
    (SECONDARY 
    STN 2)
    SUITE ROOMSECONDARYSTATION 3
    (SECONDARY 
    STN 3)
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0 
    						
    							CHAPTER 4 NDA-24315
    Page 252
    Issue 1
    AHSU: Assignment of Suite Room Station Number
    (b) When TYPE = 1 (Double Suite Room)
    TENANT
    NUMBER(TN)
    TYPE
    (TYPE)0/1
    STATION NUMBER (STN)
     PRIMARY STATION
     NUMBER 1(PRIMARY STN 1)
    PRIMARY STATION
     NUMBER 2(PRIMARY STN 2)
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1 
    						
    							NDA-24315 CHAPTER 4
    Page 253
    Issue 1
    ADSS: Assignment of Direct Station Select
    ADSS: Assignment of Direct Station Select
    1. General
    This command assigns the called number data corresponding to the Hotel Attendant Console’s Direct Station
    Select (DSS) key.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. The DSS function is only valid for the Hotel Attendant Console and may not be assigned for Business
    System Console.
    3. DSS Function Key Numbers are 1 to 10. These ten numbers correspond to values 1 to 10 for the DSS
    parameter of this command.
    4. This feature must be enabled in ASYD, SYS1, INDEX 161, bit5 in order to operate.
    3. Data Entry Instructions
    ATT
    Enter the Attendant 
    number.DC
    Destination number to be called frequently station 
    number, the specific  outside party number (including 
    the originating ACC).
    DSS
    Enter DSS Key number (1-10) ATTENDANT NUMBER (ATT)              DIRECT STATION SELECT KEY
                NUMBER  (DSS)DIGIT CODE  (DC)
      Max. 14 DIGITS 
    						
    							CHAPTER 4 NDA-24315
    Page 254
    Issue 1
    ADSS: Assignment of Direct Station Select
    4. Data Sheet
    ATTCON No. (ATN)
    DSS KEY No.(DSS)
    1 – 10
    DIGIT CODE(DC)
    MAX. 14 DIGITS
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10 
    						
    							NDA-24315 CHAPTER 4
    Page 255
    Issue 1
    ASPF: Assignment of Special Access Code Floor
    ASPF: Assignment of Special Access Code Floor
    1. General
    This command assigns Floor Data for the Access Code of the Floor Service.
    2. Precautions
    1. This command is used for the Hotel Application only.
    2. When assigning data using this command, the ASYD command, SYS 1, INDEX 165, bit7 = 1 (Floor
    Service is provided) must have been assigned.
    3. When assigning data using this command, the Access Code for Floor Service must have been assigned by
    the AASP/AGSP command, SSC = 2, SID 56.
    4. When deleting data for this command, the Access Code for Floor Service must be deleted in advance by
    the AASP/AGSP command.
    3. Data Entry Instructions
    D/NANX
    FLR
    NO.
    G
    DC D : Day Mode
    N : Night Mode
    CALLED PARTY
     INFORMATIONCALLING PARTY INFORMATION
      CALLED
      NUMBER
          (DC)
    Max. 6 digits  DAY/
    NIGHT
    MODE
     (D/N)
      D/NTENANT
    NUMBER
        (TN)SERVICE
      INDEX
    NUMBER
    (NO.) 0-15ANNEX
      (ANX)
        0-3  GROUND
    FLOOR AND
       ABOVE/
       BELOW
           (G)
           0/1  FLOOR
     NUMBER 
    (FLR)1-127 0 : Main Building
    1 : Annex 1
    2 : Annex 2
    3 : Annex 3Floor Number (1-127)
    Enter SERVICE INDEX NUMBER
    (NO.) assigned in the AASP/AGSP
    command.Ground/Underground
    0 : Ground
    1 : UndergroundEnter the called number such as a station
    number. 
    						
    							CHAPTER 4 NDA-24315
    Page 256
    Issue 1
    ASPF: Assignment of Special Access Code Floor
    4. Data Sheet
    CALLED PARTYINFORMATIONCALLING PARTY INFORMATION
    CALLEDSTATION
    NUMBER(DC)MAX. 6 DIGITS
    DAY / N I G H T
    MODE(D/N)D/N
    TENANTNUMBER
    (TN)
    SERVICE INDEXNUMBER (No.)
    0 – 15
    ANNEX(ANX)
    0 – 3
    GROUND
    FLOORANDABOVE/BELOW
    GROUP(G)0/1
    FLOOR
    NUMBER(FLR)1 – 127 
    						