Page 51
NEAX2400 IPX Feature Programming ManualPage 8NDA-24297, Issue 1 A-4 Attendant Keypad A-4 Attendant Keypad General Description This feature permits the Attendant to dial all calls from the ATTENDANT CONSOLE [A-3] via a push-button PAD. Operating Procedure Refer to the description of each service feature related to Attendant Console. Service Conditions 1. Whether the NEAX2400 IPX is equipped with DP or DTMF trunk lines, signals from the ATTENDANT KEY PAD will be converted. 2. Via the key pad, the Attendant...
Page 52
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 9 Attendant Lockout A-5 A-5 Attendant Lockout General Description This feature denies an Attendant the ability to re-enter an established trunk/station connection without being recalled by the station. Operating Procedure No manual operation is required once this feature has been programmed into system data. Service Conditions 1. This feature is, by definition, mutually exclusive with: ATTENDANT OVERRIDE [A-7] BUSY VERIFICATION [B-3] 2....
Page 53
NEAX2400 IPX Feature Programming ManualPage 10NDA-24297, Issue 1 A-6 Attendant Loop Release A-6 Attendant Loop Release General Description This feature allows an ATTENDANT CONSOLE loop to become available for a second call as soon as the Attendant has directed the first call to a station, even if that station does not answer. Operating Procedure 1. ATTENDANT CONSOLE indicates an incoming call. 2. Press the ANSWER or INCOMING CALL INDICATION [I-2] key. 3. Dial the desired telephone number; receive...
Page 54
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 11 Attendant Loop Release A-6 Interactions (cont’d) 6. Calls processed via SERIAL CALL [S-15] are not released from the Attendant Console. These calls remain in the loop until completion. Programming ASYD- System Data 2, Index 2, Bit 5. Assign as data“1.”Assign on a per-tenant basis.
Page 55
NEAX2400 IPX Feature Programming ManualPage 12NDA-24297, Issue 1 A-7 Attendant Override A-7 Attendant Override General Description This feature permits an Attendant to enter a busy trunk connection within the NEAX2400 IPX, via the Attendant Console [A-3]. Upon activation, a warning tone will be heard by the connected parties, after which they will be connected with the Attendant in a three-way bridge. Operating Procedure 1. Press the TKSL key. 2. Dial the desired trunk route (2 or 3 digits) and the...
Page 56
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 13 Attendant Override A-7 Service Conditions (cont’d) 4. Each tone burst is 0.08 seconds in duration and is used to alert both parties that the Attendant is overriding the conversation. 5. This feature can be denied on DICTATION [D-3] and PAGING [P-1] connections by assigned ARTD data. 6. It is possible, via system data, to completely disable the sending of warning tone during an ATTENDANT OVERRIDE connection. Normally the two burst Warning...
Page 57
NEAX2400 IPX Feature Programming ManualPage 14NDA-24297, Issue 1 A-7 Attendant Override Interactions (cont’d) 4. CALL FORWARDING - ALL CALLS [C-5], BUSY [C-2] or DON’T ANSWER [C-3]: If an Attendant attempts to busy verify an idle or busy station line that has activated the Call Forwarding feature, busy verification of the destination station will occur. If an Attendant attempts to busy verify an idle or busy station which is call forwarded to the Attendant Console, ATTENDANT OVERRIDE will not be...
Page 58
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 15 Automatic Recall A-8 A-8 Automatic Recall General Description This feature works as a timed reminder. When a call handled by the Attendant remains on hold, camped-on, or ringing unanswered for a fixed interval, the Attendant is automatically alerted. Operating Procedure No manual operation is required. Service Conditions 1. AUTOMATIC RECALL [A-8] timing is preset in system data at 30 seconds. See VARIABLE TIMING PARAMETERS[V-1]for other...
Page 59
NEAX2400 IPX Feature Programming ManualPage 16NDA-24297, Issue 1 A-8 Automatic Recall Programming ASYD- System Data 1, Index 145. Timer Class 1 = 2 second. For normal operation, assign 00H [RAM data is 94H]. Any call that uses AUTOMATIC RECALL keeps one of the Attendant Console switched loops busy. Since there are six loops per Attendant console, the maximum use of this feature is limited to that number. The AUTOMATIC RECALL interval (normally set for 30 seconds) is a system option (System Data 1, Index...
Page 60
NEAX2400 IPX Feature Programming Manual NDA-24297, Issue 1Page 17 Automatic Recall - DtermA-8D A-8D Automatic Recall - Dterm General Description This feature works as a timed reminder. When a Dtermhandled call remains on hold (EXCLUSIVE HOLD [E-4D] or NON-EXCLUSIVE HOLD [N-7D]) or during an unattended transfer for a variable, programmable period of time, the D termis automatically alerted. Operating Procedure No manual operation is required. Service Conditions 1. AUTOMATIC RECALL - Dtermtiming is...