Page 261
CHAPTER 5 ND-70290 (E) Pag e 2 44 Revision 3.0 ASPA ASPA : Assignment of Special Access Code 1. GENERAL This command is used to determined the kind of service and its Access Code to be executed. List Up Command: LSPA 2. PRECAUTIONS This part describes only the content of the command added in the PCS system. For more details, refer to the “Office Data Specification”.
Page 262
ND-70290 (E) CHAPTER 5 Page 245 Revision 3.0 ASPA 3. DATA ENTRY INSTRUCTIONS Access code (Max. 6 digits) TENANT NUMBER ( TN )ACCESS CODE ( ACC ) MAX. 6 DIGITSCONNECTION STATUS ACC CI N = Normal service H = Hooking service B = Busy service INDEX ( CI )KIND OF SERVICE ( SRV ) SRV STN = Station SSCA = Service code appendix OGCA = Outgoing call with route advance LCR = Least cost routingSSC = Service code OGC= Outgoing call UNIF = Office termination ANNC = Announcement service-single announcement ANNCM =...
Page 263
CHAPTER 5 ND-70290 (E) Pag e 2 46 Revision 3.0 ASPA When SRV = SSCA (Service code appendix) is assigned; NND appears when SIDA=97 (Call Hold Conference). The number of digits for an access code should be assigned in NND. NND SERVICE INDEX A ( SIDA ) 1 - 255 NECESSARY DIGIT ( NND ) 1 - 6 1-100Note 101 102C.F-PS Incoming Incomplete: Set C.F-PS Incoming Incomplete: Cancel 103~107 Note SIDA SIDA Service Name 108 109 110~113 114 115 116~255Number Sharing : Set Number Sharing : Cancel Call Forwarding-Dropped...
Page 264
ND-70290 (E) CHAPTER 5 Page 247 Revision 3.0 ASPA 4. DATA SHEET SRV=SSCA Service code Appendix Note:Refer to the “Office Data Specification” regarding this data. TENANT NUMBER (TN)ACCESS CODE (ACC) MAXIMUM 6 DIGITSCONNECTION STATUS INDEX (CI) N/H/BKIND OF SERVICE (SRV)SERVICE FEATURE INDEX (SIDA) 1 - 255NUMBER OF NEC- ESSARY DIGITS (NND)SERVICE CONTENTS 1 100 Note NNormal SSCA 101Call Forwarding Incoming Incomplete Set H Hooking BBusy NNormal SSCA 102 Incoming Incomplete Cancel H Hooking BBusy 103...
Page 265
CHAPTER 5 ND-70290 (E) Pag e 2 48 Revision 3.0 ASYD ASYD : Assignment of System Data 1. GENERAL The ASYD/ASYDL command is used to assign the system data of the following node; Local Node (LN) / Network Control Node (NCN) of the Fusion network. Stand alone PBX. List Up Command: LSYD 2. PRECAUTIONS This part describes only the contents of the command added in Built-in PCS system. For more details, refer to the “Office Data Specification.”
Page 266
ND-70290 (E) CHAPTER 5 Page 249 Revision 3.0 ASYD 3. DATA ENTRY INSTRUCTIONS Define each bit corresponding data with referring to the SYSTEM DATA CONTENTS SYSTEM DATA TYPE ( SYS )DATA ( DATA ) 00-FF ( Hex ) SYSTEM DATA INDEX ( INDEX ) 0 - 511 BIT CORRE- SPONDING DATA DATA 0 / 1BITSYSTEM DATA CONTENTS DATA DATA BIT BIT DATA Hex 1 1b0 b1 b2 b3 b4 b5 b6 b7 1 0 0 0 0 0 0n n+1 FF031 1 0 0 0 0 0 0b0 b1 b2 Not used Not used Not used Not used Not used Not used Number of zzz b3 b4 b5 b6 b7xxx service 0/1=Not to...
Page 267
CHAPTER 5 ND-70290 (E) Pag e 2 50 Revision 3.0 ASYD SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00-FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 15b 0 Access Code for C.F.-Busy Line and C.F. – Don’t Answer Services 0/1 = Same/Separate Note 1:If a PCS system, C.F.-PS Incoming Call Incomplete also refers to this system data. Note 2:If “0” is assigned, assign either SID: 10 or 12 in command “ASPA”. b 1Maximum number of Multiple Call Forwarding – All...
Page 268
ND-70290 (E) CHAPTER 5 Page 251 Revision 3.0 ASYD 4. SYSTEM DATA PROGRAMMING SHEET (1) S Y S 1 SYSTEM DATA INDEX 0-511DATA 00-FFB I TSYSTEM DATA CONTENTS 30 060 Mounting Capacity of Data Memory (DM) : 1~63 Mbyte (01~3F) Normally assigned as “6” 1 2 3 4 5 6 7 4200Access code using Pre-set dialing (e.g.: Special Access Code + Station number) 0/1 : Out/In service 1By cancelling C.F.-PS INCOMING INCOMPLETE 0 = C.F.-DROPPED CALL is also cancelled 1 = C.F.-DROPPED CALL is not cancelled 2Not used 3 4 5 6 7...
Page 269
CHAPTER 5 ND-70290 (E) Pag e 2 52 Revision 3.0 ASYD S Y S 1 SYSTEM DATA INDEX 0-511DATA 00-FFB I TSYSTEM DATA CONTENTS 4210 Miscellaneous Time Counter (MTC) is to be assigned a value from 1 Hex to F Hex.1) Announcement PS-Out of Zone disconnection timer (Release Guard timer) Timer value setting is as follows: (TC) sec. × (MTC) When the data is assigned as 00, the default data is 30 sec. 1 2 3 4 Timer class (TC) 0 : – 3 : 2 sec. 6 : – 1 : – 4 : – 7 : – 2 : – 5 : – 5 6 7 Not used 4220Miscellaneous...
Page 270
ND-70290 (E) CHAPTER 5 Page 253 Revision 3.0 AAED AAED : Assignment of Announcement Equipment Data 1. GENERAL This command is used to assign the trunk information related to Announcement Equipment on a tenant basis. List Up Command: LAED 2. PRECAUTIONS This part describes only the contents of the command added in PCS system. For more details, refer to the “Office Data Specification”.