Page 191

CHAPTER 4 ND-70290 (E)
Pag e 1 74
Revision 3.0
CALL PARK
4. INTERACTIONS
The following features cannot be activated to a PS/station that has been set Call Park:
 Busy Verification
 Call Waiting
 Attendant Camp-On with Tone Indication
 Executive Right of Way-D
term
5. PROGRAMMING
1) ASYD (Assignment of System Data)
SYS1 INDEX139 bit0-6
Assignment of No Answer Timer for Automatic Recall. (default: 30 sec.)
SYS INDEX142 bit0-6
Assignment of Automatic Recall Timer for Call Park. (default: 500 sec.)
SYS1...

Page 192

ND-70290 (E) CHAPTER 4
Page 175
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
1. GENERAL DESCRIPTION
This feature enables a PS user to call a maximum of “20-Party (self + other 19 members)” conference, by only
dialing a pre-programmed Group Calling Conference Number. If the Group Calling Conference Number is once
dialed, the member stations/PSs are automatically called in assigned order at the interval of every 2 seconds.
This feature also allows...

Page 193

CHAPTER 4 ND-70290 (E)
Pag e 1 76
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
3. SERVICE CONDITION
1. Conference leader and conferee must be a station/PS.
2. PA-CFTB can be available for Group Calling Conference.
Note:The following table shows conditions of CFTB circuit card to use this feature. 
3. The maximum number of CFTB circuit cards per one conference group is 3. A conference leader port and
19 conferee ports are allocated as follows.
Note:The number of CFTB circuit cards required to...

Page 194

ND-70290 (E) CHAPTER 4
Page 177
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
6. By making a group of Station Hunting Group-Circular between conference leader ports or conference leader
ports for cascade connection of multiple sets of CFTB circuit cards, the conference can be held looking for
idle CFTB circuit cards when dialed port is already used by others. The below shows an example of this
feature using Station Hunting-Circular.
Figure 4-7  Group Call-Automatic Conference using Station...

Page 195

CHAPTER 4 ND-70290 (E)
Pag e 1 78
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
13. ISDN terminal and Attendant Console are not available in this feature.
14. Conference leader cannot call a conference using Blind Transfer.
15. If programming the ASDT command data (TEC=14: Hot Line) to CFTB circuit card, the user must also
assign ALGSL/ALGSN command and AHLGL/AHLGN command to the card, otherwise when user dials
this feature access code, an Attendant Console is called by Hot Line function.
16....

Page 196

ND-70290 (E) CHAPTER 4
Page 179
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
4. PROGRAMMING
 Entry procedure (Standalone)
1) ASYD (Assignment of System Data)
SYS1 INDEX20 b6=0  (Line Circuit Reverse Relay Control when Reorder Tone is connected to 
a station.) 
Note 1
SYS1 INDEX139 (No Answer Timer for Station to Station, DID and Tie Line calls.)
Note 1:Only when using firmware SP-1141.
2) ANPD (Assignment of Numbering Plan)
Assign the first digit and the necessary number of digits needed to...

Page 197

CHAPTER 4 ND-70290 (E)
Pag e 1 80
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
5) ASFC (Service Feature Class Data)
Allow the following Service Feature to the levels 0-7 on the CFTB circuit card.
SFI=71 (Distinctive Dial Tone)
SFI=72 (Called Station Hooking Restriction)
SFI=32 (Line Circuit Reverse Relay Control) 
Note 6
Note 5:
Do not allow the other service restriction data.
Note 6:Only when using firmware SP-1141.
6) ASPAL (Assignment of Special Access Code for LDM)
Assign Telephone Number...

Page 198

ND-70290 (E) CHAPTER 4
Page 181
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
 Cancel Procedure
When deleting the ASDT/ALGSL/APHNL command data assigned as conferee, the user must first,
delete the AHLGL data.10) ASHC (Assignment of Station Hunting Group-Circular)
Assign Station Hunting Group-Circular between conference leader ports and/or conference 
leader ports for cascade connection on each set of CFTB circuit cards.
Note 10:This command is required, only when calling a conference...

Page 199

CHAPTER 4 ND-70290 (E)
Pag e 1 82
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
 Entry procedure (Fusion Network)
1) ASYD (Assignment of System Data)
SYS 1 INDEX 20 b6=0 (Line Circuit Reverse Relay Control when Reorder Tone is connected 
to a station.) 
Note 1
SYS 1 INDEX 139 (No Answer Timer for Station to Station, DID and Tie Line calls.)
Note 1:Only when using firmware SP-1141.
2) ANPD (Assignment of Numbering Plan)
Assign the first digit and the necessary number of digits needed to...

Page 200

ND-70290 (E) CHAPTER 4
Page 183
Revision 3.0
GROUP CALL-AUTOMATIC CONFERENCE (20-PARTY)
5) ASFC (Service Feature Class Data)
Allow the following Service Feature to the levels 0-7 on the CFTB circuit card.
SFI=71 (Distinctive Dial Tone)
SFI=72 (Called Station Hooking Restriction)
SFI=32 (Line Circuit Reverse Relay Control) 
Note 7
Note 6:
Do not allow the other service restriction data.
Note 7:Only when using firmware SP-1141.
6) ASPAN (Assignment of Special Access Code for NDM)
Assign Telephone Number to...