Page 131

CHAPTER 4 ND-70290 (E)
Pag e 1 14
Revision 3.0
AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE
4. PROGRAMMING
 Entry Procedures
1) ARTD (Route Class Data)
Assign the Route Class Data of the announcement trunk.
RT : Route Number
OSGS (CDN: 1) = 2
ONSG (CDN: 2)= 2
TF (CDN: 5) = 1
TCL (CDN: 6) = 4
L/T (CDN: 7) = 1
ANS (CDN: 28) = 1
Assign “0” for other data.
2) ALRTN (Assignment of Logical RT in Network Data Memory)
LGRT : Logical Route Number
FPC : Fusion Point Code
RT : Route Number
Note:Not necessary...

Page 132

ND-70290 (E) CHAPTER 4
Page 115
Revision 3.0
AUTOMATIC ANNOUNCEMENT-DISCONNECTED PS OUT OF ZONE
3) MBTK (Make Busy of Trunk)
Set the announcement trunk in a make-busy cancel state
4) ARSC (Route Restriction Class Data)
Assign the Route Restriction Class of the station which allows access to the announcement trunk.
D/N : Day/Night Mode
TN : Tenant Number
RT : Route Number
RSC : Route Restriction Class (0-15)
RRI :  Route Restriction Index (0-3)
RES = 1 (Allowed)
5) ARRC (Alternative Route Restriction...

Page 133

CHAPTER 4 ND-70290 (E)
Pag e 1 16
Revision 3.0
NAME DISPLAY
NAME DISPLAY
1. GENERAL DESCRIPTION
This feature allows a PS to indicate the user information corresponding to the calling station number while
engaged in a station-to-station call.
2. OPERATING PROCEDURE
Examples of LCD display are shown below.
 When originating a station-to-station call:
LCD display of the calling station:
LCD display of the called station:
 When a station call has been transferred to another station by Call Forwarding-All...

Page 134

ND-70290 (E) CHAPTER 4
Page 117
Revision 3.0
NAME DISPLAY
3. SERVICE CONDITIONS
1. This feature is available for Series 7300 or later software.
2. User information corresponding to the station number that can be displayed on the LCD is a maximum of
16 digits.
3. User information is displayed on the LCD, intended to the left. The information may consist of upper case
letters, numeric characters, and most keyboard symbols.
4. When user information is 12 digits or more, the first or last part of information...

Page 135

CHAPTER 4 ND-70290 (E)
Pag e 1 18
Revision 3.0
NAME DISPLAY
4. PROGRAMMING
1) ASYD (Assignment of System Data)
SYS1
SI 78
b5: 1 (Name Display In Service)
SI 79
b6: 0 (OAI In Service)
SI 241
b1: The number of digits displayed in NAME DISPLAY service
0/1: 8 digits/16 digits
2) ANDD (Assignment of Name Display Data)
Assign user’s information to Physical Station Number.
TN : Tenant Number
STN : Physical Station Number
NAME : User information (Maximum 16 digits)
 END
 START 

Page 136

ND-70290 (E) CHAPTER 4
Page 119
Revision 3.0
NAME DISPLAY - CCIS
NAME DISPLAY - CCIS
1. GENERAL DESCRIPTION
In between CCIS nodes, this feature allows calling or called party information to be displayed on the LCD of a
PS.
2. OPERATING PROCEDURE
Examples of LCD display are shown below.
 When originating a call:
LCD display of the calling station:
LCD display of the called station:
 When a call has been transferred to another station by Call Forwarding-All Calls/Busy Line/Don’t Answer/
PS-Incoming...

Page 137

CHAPTER 4 ND-70290 (E)
Pag e 1 20
Revision 3.0
NAME DISPLAY - CCIS
3. SERVICE CONDITIONS
1. This feature is available for Series 7300 or later software.
2. User information corresponding to the station number that can be displayed on the LCD is a maximum of
16 digits.
3. User information is displayed on the LCD, intended to the left. The information may consist of upper case
letters, numeric characters, and most keyboard symbols.
4. When user information is 12 digits or more, the first or last part of...

Page 138

ND-70290 (E) CHAPTER 4
Page 121
Revision 3.0
NAME DISPLAY - CCIS
4. PROGRAMMING
1) ASYD (Assignment of System Data)
SYS1
SI 78
b5: 1 (Name Display In Service)
SI 79
b6: 0 (OAI In Service)
SI 241
b1: The number of digits displayed in NAME DISPLAY service
0/1: 8 digits/16 digits
2) ARTD (Assignment of Route Class Data)
Assign route class data for the CCIS route.
CDN 43 (BT)=1
CDN 50 (DPLY)=1
CDN 98 (CI)=0/1 with ISDN
CDN 112 (IND)=1
3) ANDD (Assignment of Name Display Data)
Assign user’s information to...

Page 139

CHAPTER 4 ND-70290 (E)
Pag e 1 22
Revision 3.0
NUMBER SHARING
NUMBER SHARING
1. GENERAL DESCRIPTION
This feature allows the Dterm user to use a PS as a sub station. In this feature, the Dterm and PS are referred as
Main Station and Sub Station, respectively. The main functions of this feature are as follows:
1. Call Forwarding-All Calls to PS
When the D
term (Main Station) user presses the feature key or dials the access code, Call Forwarding-All
Calls to PS (Sub Station) is set or canceled. This...

Page 140

ND-70290 (E) CHAPTER 4
Page 123
Revision 3.0
NUMBER SHARING
3. SERVICE CONDITIONS
1. This feature is available for Series 7300 or later software.
2. Telephone Number must be assigned to both Main and Sub Stations.
3. The PS cannot be assigned as Main Station.
4. Any combination of Main Station and Sub Station is available in a Fusion network.
5. The access code
 for an outgoing call cannot be assigned as a Sub Station number.
6. Dialing the access code for this feature is available only for Main Station...
Start reading NEC Neax 2400 Imx Wireless System Manual