CHAPTER 8 NDA-24238
Page 544
Revision 3.0
MAINTENANCE COMMANDS
CSCL:Continuous Change of Station Class
1. Functional Outline
This command can change the station class information (TEC, RSC, SFC) en bloc by designating the range of
the station number.
2. Parameters
Input Data
TN: Tenant Number
STN(START): First Station Number [0-9, #, * (Max. 6 digits)] 
Note 1
STN(END): Last Station Number [0-9, #, * (Max. 6 digits)]Note 1
TEC(OLD): Telephone Equipment Class before change [1-31]Note 2, Note 3
TEC(NEW):...

Page 572

NDA-24238 CHAPTER 8
Page 545
Revision 3.0
MAINTENANCE COMMANDS
CSTN:Continuous Change of Station Number
1. Functional Outline
This command can change the consecutive station numbers en bloc by designating the station number range.
2. Parameters
Input Data
TN: Tenant Number 
OLD STN(START): First Station Number before change [0-9, #, * (Max. 6 digits)] 
Note
OLD STN(END): Last Station Number before change [0-9, #, * (Max. 6 digits)] Note
NEW STN(START): First Station Number after change [0-9, #, * (Max. 6...

Page 573

CHAPTER 8 NDA-24238
Page 546
Revision 3.0
MAINTENANCE COMMANDS
DCBD:Display of Call Block Entry Data
1. Functional Outline
This command is used to display the following Call Block data, assigned to a station:
 Number of station/trunk whose call is to be blocked (in the remainder of this page, denoted as “Restriction
Number”)
 Registered “Restriction Numbers” in total
These data can be obtained by entering any of the station’s Telephone Number (TYPE 1), Physical Station
Number (TYPE 2) or LENS (TYPE 3)...

Page 574

NDA-24238 CHAPTER 8
Page 547
Revision 3.0
MAINTENANCE COMMANDS
Display Data
CNT: Registered “Restriction Numbers” in total (1-5)
DC: Each “Restriction Number”
 When Physical Station Number is registered – Max. 6 digits
 When Telephone Number is registered – Max. 16 digits
 When Trunk Call Number is registered – Max. 32 digits 

Page 575

CHAPTER 8 NDA-24238
Page 548
Revision 3.0
MAINTENANCE COMMANDS
DCEN:Display of Connection Trunk LENS Data for LDM
1. Functional Outline
This command is used to display the registered connection trunk/route data by designating LENS.
2. Parameters
Input Data
C_LENS: Line Equipment Number [6 digits]
Display Data
C_RT: Connection Route Number [1-1023]
C_TK: Connection Trunk Number [1-4095]
RT: External Route Number
TK: Trunk Number [1-255]
TN: Tenant Number 

Page 576

NDA-24238 CHAPTER 8
Page 549
Revision 3.0
MAINTENANCE COMMANDS
DCON:Display of Connection Status
1. Functional Outline
This command displays the connection status of the station and trunks. If the specified station or trunk is busy,
the connected party is displayed.
2. Parameters
Input data
Type: Kind of Connection Status (1-4)
1=Station of Connection Status
2=Trunk of Connection Status
3=LENS of Connection Status
4=Connection Trunk of Connection Status (Fusion Network)
TN:
Note 1
STN: Maximum number of...

Page 577

CHAPTER 8 NDA-24238
Page 550
Revision 3.0
MAINTENANCE COMMANDS
DFTD:Display of System Message Details
1. Functional Outline
This command is necessary to print the system messages detected by the Fault Diagnostic programs.
When the fault scanning (Scanning PBX) is effective, the MAT can scan the PBX status by polling every 20
sec, (default setting is Effective.)
If the PBX has faults, this command executes automatically.
2. Parameters
Input data
New/Old
Show Details: YES/NO 

Page 578

NDA-24238 CHAPTER 8
Page 551
Revision 3.0
MAINTENANCE COMMANDS
DISS:Display of Program Issue
1. Functional Outline
This command outputs to the printer and displays at the MAT, the program information (version, issue No. and
date) in the main memory, and the program information (SP No.and issue No.) in the port microprocessor
memory mounted in each circuit card in the PBX.
2. Parameters
Input data
Type of Issue: Main Memory
Port Microprocessor
Module Group:
Note 1
Unit:Note 1
Display data
Type: Main...

Page 579

CHAPTER 8 NDA-24238
Page 552
Revision 3.0
MAINTENANCE COMMANDS
DLEN:Display of LENS Data
1. Functional Outline
This command displays the data (station data or trunk data) assigned for a designated LEN. For Hotel system,
Room Class and Floor Service Data [Annex (ANX), Ground/Underground (G), Floor (FLR)] displays also.
2. Parameters
Input data
LENS
Display data
TN
STN: Maximum 6 digits
TEC: Telephone Equipment Number (1-31) (See Table 8-4.)
RSC: Route Restriction Class (0-15)
SFC: Service Feature Class...

Page 580

NDA-24238 CHAPTER 8
Page 553
Revision 3.0
MAINTENANCE COMMANDS
G: 0=Ground
1=Underground
FLR: Floor (1-127)
RT: Internal Route Number (See Table 8-5.)
TK
C_RT: Connection Route Number (1-1023)
C_TK: Connection Trunk Number (1-4095)
Table 8-5  Internal Route Number Explanation
DATA MEANING DATA MEANING
901 Attendant Console 902 Originating Register Trunk
903 Incoming Register Trunk 904 MF Receiver
905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service
907AMP 908Not used
909 Three-Way...