CHAPTER 7 NDA-24238 Page 504 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 2.7 Alarm Tests An alarm is to be generated which will be displayed at the DESKCON/ATTCON. Be sure to inform the attendant of the test in advance. Replace the –48V fuse in the FANU with a blown fuse. Confirm that an alarm is indicated on the TOPU. Replace the blown fuse with the original –48V fuse. Using the RALM command, reset all alarm indications. START END
Page 532
NDA-24238 CHAPTER 7 Page 505 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 2.8 Main Power System Check Note:For a longer battery life, observe the following items: Place the batteries in a dark, cool place. Keep the room temperature within the range of 10°C to 35°C (40°F to 85°F). Floating voltage must be kept within the range of the battery specification at all times. After discharging, perform equalized charging as per the battery specification. Check the load voltage (DC –48V ±5 V) of the rectifier....
Page 533
CHAPTER 7 NDA-24238 Page 506 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 2.9 Trunk RGU Check Check alarm lamps on the line/trunk circuit cards. Check to see if a system message pertaining to a circuit card has been output. Check the speech path for each PIM and also check ringing signal. START END
Page 534
NDA-24238 CHAPTER 7 Page 507 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 2.10 ATTCON/DESKCON Check (1) Attendant Console Check Note:Adjusting Time Method (see Figure 7-2.) If the Hour (H) button is pushed once, the time will advance one hour. (To push the button, use a thin object, such as a toothpick.) If the H button is held continuously, the time will advance one hour each second. If the Minute (M) button is pushed once, the time will advance one minute. If the M button is held continuously, the...
Page 535
CHAPTER 7 NDA-24238 Page 508 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE (2) Desk Console Check Note 1:The lamp checks can be suspended any time when the * key on the control panel is pressed. Note 2:The DESKCON obtains time information only from the PBX side. Therefore, adjust the time and date using the MAT command. Figure 7-3 Desk Console Ask the operator at each DESKCON if the DESKCON is operating normally. On the DESKCON control panel, each operator presses the L3, SRC, and Release keys...
Page 536
NDA-24238 CHAPTER 7 Page 509 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 2.11 System Check Check the OPE lamps (green) on all circuit cards. Check whether a system message pertaining to the CPU/TSW has been output. Check speech conditions by establishing a station-to-station connection at each PIM. If the condition is abnormal, determine the nature of the problem (dial tone cannot be heard, no speech can be established, etc.) Does the condition occur in No. 0 TSW or in No. 1 TSW? Does the condition occur...
Page 537
CHAPTER 7 NDA-24238 Page 510 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE 3. ROUTINE MAINTENANCE CHECK LISTS This section provides check lists (Maintenance Procedure Reports) to be used when performing routine main- tenance. The Routine Maintenance Check Lists consists of the following items: Maintenance Procedure Report C.O. Trunk/Tie Line Register/Sender Trunk (RST) Digital Conference Function Speech Path for each PIM, and Ringing Generator Unit Attendant/Desk Console
Page 538
NDA-24238 CHAPTER 7 Page 511 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE USER NAMESIGNATURE OF SUPERVISORWORK TIME (FROM - ) Name of User (Company) Date: Maintenance ClassificationRoutine/Non- routine Control No. Maintenance Company Name of Equipment Room Temperature - °C °F & humidity %Name of Worker Reference SectionItem Detail Check Reference SectionItem Detail Check 2.1Check of Ambient Conditions in the Switch RoomAmbient Temperature2.9Trunk RGU Check SND Trunk Relative humidity DCF Function...
Page 539
CHAPTER 7 NDA-24238 Page 512 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE C.O. Trunk/Tie Line TEST TYPE TEST ITEM CONNECTION DIAGRAM C.O. Trunk/Tie Line Speech Path Test Set up a speech path test by seizing a trunk using the Station or ATTCON/DESKCON connection test diagrammed to the right. Connection Test-Station Connection Test-ATTCON/DESKCON C.O. Trunk/Tie Line NAME OF TRUNK ROUTEACCESS NUMBERROUTE NUMBERTRUNK NUMBERCHECK REMARKS LCTRK C.O./Tie Line ATITRK C.O./Tie Line ATTCON/ DESKCON
Page 540
NDA-24238 CHAPTER 7 Page 513 Revision 3.0 ROUTINE MAINTENANCE PROCEDURE Register/Sender Trunk (RST) TEST TYPE TEST ITEM CONNECTION DIAGRAM ORT Function Perform the test by specifying an ORT using the Connection Test-Station. Confirm that [6-I] system message displays as a result of the test.DP/PB SENDER Function Perform the test by specifying an ORT using the Connection Test-Station. Confirm that [6-I] system message displays as a result of the test. LC ORT LC~ SND ORT