Page 551
CHAPTER 8 NDA-24238 Page 524 Revision 3.0 MAINTENANCE COMMANDS AT R F :Assignment of Traffic Measurement Order 1. Functional Outline This command is used to assign and delete traffic measurement programs. A request for traffic measurement is performed when a traffic measurement instruction has been assigned by this command. The collected traffic measurement data can be stored on the HD of the MAT, which can be designated on the basis of traffic measurement type. 2. Parameters Input Data TYPE: Type of...
Page 552
NDA-24238 CHAPTER 8 Page 525 Revision 3.0 MAINTENANCE COMMANDS ATRFN:Assignment of Traffic Measurement Order for Fusion Network 1. Functional Outline This command is used to assign and delete traffic measurement programs available on the Ethernet. A request for traffic measurement is performed on a network basis when a traffic measurement instruction has been assigned by this command. The collected traffic measurement data can be stored on the HD of the MAT (connected to the NCN: Network Control Node),...
Page 553
CHAPTER 8 NDA-24238 Page 526 Revision 3.0 MAINTENANCE COMMANDS BOSD:Back Up One-Touch Speed Call Memory Data 1. Functional Outline Save Function Saves the data residing in the One-Touch Speed Call Memory of DLC/ELC card onto a floppy disk. Verify Function Verifies the One-Touch Speed Call Memory data saved on the floppy disk with the data residing in the One-Touch Speed Call Memory of DLC/ELC card. Load Function Loads the One-Touch Speed Call Memory data saved in the floppy disk into the...
Page 554
NDA-24238 CHAPTER 8 Page 527 Revision 3.0 MAINTENANCE COMMANDS CADSD:Continuous Assignment of Station Data 1. Functional Outline This command can assign/delete many station data simultaneously which have consecutive numbers. 2. Parameters Input Data Type: Assign/Delete [When Assign is selected in the Type selection list box] TN(START): Start Tenant Number TN(END): End Tenant Number STN(START): Start Station Number [Max. 6 digits] Note 1 STN(END): End Station Number [Max. 6 digits] Note 1 STEP: Station...
Page 555
CHAPTER 8 NDA-24238 Page 528 Revision 3.0 MAINTENANCE COMMANDS TEC: Telephone Equipment Class [1-31] 1=DP (10pps) 2=PB 3=DP/PB 4=DP (20pps) 5-11=Not used 12=D term 13=Data Terminal via Dterm14=Hot Line 15=CAS Line 16=Data Terminal via Data Module 17=Not used 18=Virtual Line Appearance (for D term Multi-Line) 19-22=Not used 23=ISDN Terminal 24-26=Not used 27=8 Conference Equipment 28-31=Not used RSC: Route Restriction Class [0-15] SFC: Service Feature Class [0-15] Buttons Execute: Click to make the input...
Page 556
NDA-24238 CHAPTER 8 Page 529 Revision 3.0 MAINTENANCE COMMANDS When Delete is selected in the Type selection list box Input Data TN(START): First Tenant Number TN(END): Last Tenant Number STN(START): First Station Number [Max. 6 digits] STN(END): Last Station Number [Max. 6 digits] STEP: Station Count-up Step Note 1 If using * and # → [1-12] If not using * and # → [1-10] Note 1:In this parameter, specify the size of increment between the consecutive station numbers to be deleted. See the example below:...
Page 557
CHAPTER 8 NDA-24238 Page 530 Revision 3.0 MAINTENANCE COMMANDS CATK:Continuous Assignment of Trunk Data 1. Functional Outline This command can assign/delete many trunk data simultaneously which have consecutive numbers. 2. Parameters Type/KIND ( Note): Assign/Delete Note:Type (for software Release 6 or earlier) KIND (for software Release 7 or later) When “Assign” is selected in the “Type/KIND” selection list box Input Data RT: R o u t e N u m b e r TK (START): First Trunk Number [1-768] TK (END): Last...
Page 558
NDA-24238 CHAPTER 8 Page 531 Revision 3.0 MAINTENANCE COMMANDS Buttons Execute: Click to make the input data valid. Cancel: Click to cancel the input data. Exit: Click to exit this command. Display Data TK: Assigned Trunk Number LENS: Line Equipment Number STATUS: Data Entry Result OK=Data Assignment is successful Note 4 Note 4: If not OK (i.e. the data entry is not successful), related error message is displayed here.
Page 559
CHAPTER 8 NDA-24238 Page 532 Revision 3.0 MAINTENANCE COMMANDS When “Delete” is selected in the “Type/KIND” selection list box Input Data RT: R o u t e N u m b e r TK(START): First Trunk Number [1-768] TK(END): Last Trunk Number [1-768] STEP: Trunk Count-up Step [1-10] Note 1 Buttons Execute: Click to delete the input data. Cancel: Click to cancel the deletion. Exit: Click to exit this command. Display Data TK: Trunk Number STATUS: Result of Deletion OK=Deletion Success Note 2 Note 1: In this...
Page 560
NDA-24238 CHAPTER 8 Page 533 Revision 3.0 MAINTENANCE COMMANDS Details on Trunk Arrangement TYPE When assigning the consecutive trunk data by using the CATK command, you must select the trunk arrangement type (1-6) in the TYPE parameter. The following are examples of accommodated 16 COT circuit cards: TYPE=1 (Level → Group → Unit) Trunk data is arranged in the following numerical order. U=2 00 PIM C/EU=3 05 10 15 20 16 C O16 C O16 C O 16 C O16 C O 16 C O PIM C/E U=0U=1 TTT T T T LV 7 LV 6 LV 5 LV 4 LV 3...