CHAPTER 8 NDA-24238 Page 534 Revision 3.0 MAINTENANCE COMMANDS TYPE=2 (Level → Unit → Group) Trunk data is arranged in the following numerical order. TYPE=3 (Group → Level → Unit) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 2 3 4 5 6 7 8 0233 40 0381 88 0565 72 04 17 2449 56 05 06 U=2 U=0 03 02 9 16 00 41 48 01 57 6425 32 16 15 U=3 U=1 73 8089 96 Group No. Level No. 1MGSlot No. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV...
Page 562
NDA-24238 CHAPTER 8 Page 535 Revision 3.0 MAINTENANCE COMMANDS TYPE=4 (Group → Unit → Level) Trunk data is arranged in the following numerical order. TYPE=5 (Unit → Level → Group) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 024 88 05 7 91 8 92 05 06 U=2 U=0 03 02 5 89 006 90 01 9 93 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 16 17 18 2 033 04 19 20 21 24 LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV...
Page 563
CHAPTER 8 NDA-24238 Page 536 Revision 3.0 MAINTENANCE COMMANDS TYPE=6 (Unit → Group → Level) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 0211 95 05 3 87 7 91 05 06 U=2 U=0 03 02 2 86 006 90 01 4 89 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 23 14 18 5 039 04 15 19 16 24 92 94 20 22 810 17 21 89 93
Page 564
NDA-24238 CHAPTER 8 Page 537 Revision 3.0 MAINTENANCE COMMANDS CBCN:Control of Broadcasting for NDM 1. Functional Outline This command is used to specify the destination of NDM data broadcast from the NCN. This command is available only at the Network Control Node (NCN). 2. Parameters Input data TYPE: ALL=(All the Nodes)/ONE (One designated Node) FPC: FPC of the designated Node Note Interval: Broadcasting Interval Note:This parameter appears when ONE is selected as TYPE parameter.
Page 565
CHAPTER 8 NDA-24238 Page 538 Revision 3.0 MAINTENANCE COMMANDS CCSE:Change of Common Signaling Channel Equipment 1. Functional Outline This command is used to set/reset the make busy state of CCH circuit card. 2. Parameters CCH LENS: Line Equipment Number of CCH circuit card [5 digits] MG=XX, UNIT=X, GROUP=XX LINK: Link Status [0-2] 0=Link Open 1=Link Close 2=Not Available MB: Make Busy Information [0-2] 0=Make Idle 1=Make Busy 2=Not Available Note:This command cannot be used for the ISDN-related circuit...
Page 566
NDA-24238 CHAPTER 8 Page 539 Revision 3.0 MAINTENANCE COMMANDS CDBU:Change of Dch Backup 1. Functional Outline This command is used to execute the D-channel route changeover, associated with the D-CHANNEL BACKUP-PRI feature (for AT&T/NT/N-ISDN2). 2. Parameters Input Data MG: Module Group Number [00-07] Note CNT: Number of Dch Backup Route [1-32] Note Buttons Get: Click to get information on the Dch Routes. Change: Click to execute the Dch route changeover. Stop: Click to cancel the Dch route...
Page 567
CHAPTER 8 NDA-24238 Page 540 Revision 3.0 MAINTENANCE COMMANDS CMOD:Change of System Mode 1. Functional Outline This command is used to execute ACT/ST-BY change of the processor (CPU)/TSW and display the status of CPU/CLK/TSW. 2. Parameters Input Data TYPE: Type of Process (1,2) 1/2=Change Operating Mode/Make Busy of TSW DEVICE: Device to be changed (1,2) Note 1 1=CPU Note 2 2=TSW SW: Type of Switch Note 3 1=TSW (fixed) SYSTEM: System of Switch (0,1) Note 3 0/1=System 0/System 1 Note 1:This parameter...
Page 568
NDA-24238 CHAPTER 8 Page 541 Revision 3.0 MAINTENANCE COMMANDS CMWL:Control Message Waiting Lamp 1. Functional Outline This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the station. If the station is a D term, this command can also control Message Waiting Display on the Dterm. 2. Parameters Input Data TYPE: Type of Input (1,2) 1=Designation by Station Number 2=Designation by LEN TN: Note 1 STN: Maximum 5 digits for Business system, and 6 digits for Hotel...
Page 569
CHAPTER 8 NDA-24238 Page 542 Revision 3.0 MAINTENANCE COMMANDS CMWL_T:Control Message Waiting Lamps – Telephone Number 1. Functional Outline This command is used to control/display the Message Waiting Lamp’s ON/OFF status, by using Telephone Numbers. When the station is a D term, this command can also be used to control the Message Waiting Lamp Display. This command is available at NCN (for Fusion network) only. 2. Parameters Input Data TYPE: Designation by Telephone Number/Designation by LEN UGN: User...
Page 570
NDA-24238 CHAPTER 8 Page 543 Revision 3.0 MAINTENANCE COMMANDS CPRS:Controlled Alternate PRSCs 1. Functional Outline This command is necessary for the Controlled Alternate PRSCs function. It either selects the class used between two priority restriction classes (Normal or Urgent), or indicates the class used. This command is allowed only when bit1 of SYS 1, INDEX 59 is “1” (Controlled Alternate PRSCs in service). 2. Parameters N/U: Priority Restriction Class [N/U] N=Normal U=Urgent