CHAPTER 8 NDA-24238
Page 534
Revision 3.0
MAINTENANCE COMMANDS
TYPE=2 (Level → Unit → Group)
Trunk data is arranged in the following numerical order.
TYPE=3 (Group → Level → Unit)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6 LV 71 2
3
4
5
6
7 8
0233 40
0381 88
0565 72
04
17 2449
56
05 06
U=2
U=0
03 02 9 16
00
41 48
01
57 6425
32
16 15
U=3
U=1
73 8089
96
Group No. Level No.
1MGSlot No.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV...

Page 562

NDA-24238 CHAPTER 8
Page 535
Revision 3.0
MAINTENANCE COMMANDS
TYPE=4 (Group → Unit → Level)
Trunk data is arranged in the following numerical order.
TYPE=5 (Unit → Level → Group)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6 LV 71 13 85
024 88
05 7 91
8 92
05 06
U=2
U=0
03 02 5 89
006 90
01 9 93
16 15
U=3
U=1
12 96
Group No. Level No.
1MGSlot No.
16 17 18
2
033
04 19 20 21 24
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV...

Page 563

CHAPTER 8 NDA-24238
Page 536
Revision 3.0
MAINTENANCE COMMANDS
TYPE=6 (Unit → Group → Level)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6 LV 71 13 85
0211 95
05 3 87
7 91
05 06
U=2
U=0
03 02 2 86
006 90
01 4 89
16 15
U=3
U=1
12 96
Group No. Level No.
1MGSlot No.
23 14 18
5
039
04 15 19 16 24
92 94
20 22
810
17 21 89 93 

Page 564

NDA-24238 CHAPTER 8
Page 537
Revision 3.0
MAINTENANCE COMMANDS
CBCN:Control of Broadcasting for NDM
1. Functional Outline
This command is used to specify the destination of NDM data broadcast from the NCN. This command is
available only at the Network Control Node (NCN).
2. Parameters
Input data
TYPE: ALL=(All the Nodes)/ONE (One designated Node)
FPC: FPC of the designated Node 
Note
Interval:  Broadcasting Interval
Note:This parameter appears when ONE is selected as TYPE parameter. 

Page 565

CHAPTER 8 NDA-24238
Page 538
Revision 3.0
MAINTENANCE COMMANDS
CCSE:Change of Common Signaling Channel Equipment
1. Functional Outline
This command is used to set/reset the make busy state of CCH circuit card.
2. Parameters
CCH LENS: Line Equipment Number of CCH circuit card [5 digits]
MG=XX, UNIT=X, GROUP=XX
LINK: Link Status [0-2]
0=Link Open
1=Link Close
2=Not Available
MB: Make Busy Information [0-2]
0=Make Idle
1=Make Busy
2=Not Available
Note:This command cannot be used for the ISDN-related circuit...

Page 566

NDA-24238 CHAPTER 8
Page 539
Revision 3.0
MAINTENANCE COMMANDS
CDBU:Change of Dch Backup
1. Functional Outline
This command is used to execute the D-channel route changeover, associated with the D-CHANNEL
BACKUP-PRI feature (for AT&T/NT/N-ISDN2).
2. Parameters
Input Data
MG: Module Group Number [00-07] 
Note 
CNT: Number of Dch Backup Route [1-32] 
Note 
Buttons
Get: Click to get information on the Dch Routes.
Change: Click to execute the Dch route changeover.
Stop: Click to cancel the Dch route...

Page 567

CHAPTER 8 NDA-24238
Page 540
Revision 3.0
MAINTENANCE COMMANDS
CMOD:Change of System Mode
1. Functional Outline
This command is used to execute ACT/ST-BY change of the processor (CPU)/TSW and display the status of
CPU/CLK/TSW.
2. Parameters
Input Data
TYPE: Type of Process (1,2)
1/2=Change Operating Mode/Make Busy of TSW
DEVICE: Device to be changed (1,2) 
Note 1
1=CPU Note 2
2=TSW
SW: Type of Switch
Note 3
1=TSW (fixed)
SYSTEM: System of Switch (0,1) 
Note 3
0/1=System 0/System 1
Note 1:This parameter...

Page 568

NDA-24238 CHAPTER 8
Page 541
Revision 3.0
MAINTENANCE COMMANDS
CMWL:Control Message Waiting Lamp
1. Functional Outline
This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the
station. If the station is a D
term, this command can also control Message Waiting Display on the Dterm.
2. Parameters
Input Data
TYPE: Type of Input (1,2)
1=Designation by Station Number
2=Designation by LEN
TN:
Note 1
STN: Maximum 5 digits for Business system, and 6 digits for Hotel...

Page 569

CHAPTER 8 NDA-24238
Page 542
Revision 3.0
MAINTENANCE COMMANDS
CMWL_T:Control Message Waiting Lamps – Telephone Number
1. Functional Outline
This command is used to control/display the Message Waiting Lamp’s ON/OFF status, by using Telephone
Numbers. When the station is a D
term, this command can also be used to control the Message Waiting Lamp
Display. This command is available at NCN (for Fusion network) only. 
2. Parameters
Input Data
TYPE: Designation by Telephone Number/Designation by LEN
UGN: User...

Page 570

NDA-24238 CHAPTER 8
Page 543
Revision 3.0
MAINTENANCE COMMANDS
CPRS:Controlled Alternate PRSCs
1. Functional Outline
This command is necessary for the Controlled Alternate PRSCs function. It either selects the class used
between two priority restriction classes (Normal or Urgent), or indicates the class used. This command is
allowed only when bit1 of SYS 1, INDEX 59 is “1” (Controlled Alternate PRSCs in service).
2. Parameters
N/U: Priority Restriction Class [N/U]
N=Normal
U=Urgent 