ND-70895 (E) CHAPTER 4
 Page 31
Revision 1.0
COMMANDS
ACNO
ACNO:  Assignment of Conversion Number Data
5. Functions
This command is used to assign/delete the conversion number required for selecting a route on a each route
basis.
6. Precaution
(a) The data should be assigned to ring-down trunks.
(b) As a conversion number, a monitor number assigned by AMNO command should be set.
7. Parameters
RT : External Route Number
TN : Tenant Number of Monitored Number
MNO : Monitored Number (Max. 5 digits) 
Note...

Page 42

CHAPTER 4 ND-70895 (E)
Page 32
Revision 1.0
COMMANDS
AC NO
Conversion Number Data Assignment Table
Note:Max. 6 digits when using in a hotel system
EXTERNAL ROUTE NUMBER
(RT)TENANT NUMBER OF 
MONITORED NUMBER
(TN)MONITORED NUMBER
(MNO)
MAX. 5 DIGITS (Note) 

Page 43

ND-70895 (E) CHAPTER 4
 Page 33
Revision 1.0
COMMANDS
AKYD
AKYD:  Assignment of Key Data for Dterm
9. Functions
This command is used to assign/delete/display the function key data, multi-line data or intercom data
corresponding to each key on such multi-function telephone terminal as D
term Series E.
10. Precaution
For the details of D
term data, refer to the description of AKYD command in the Feature Programming
Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited...

Page 44

CHAPTER 4 ND-70895 (E)
Page 34
Revision 1.0
COMMANDS
AMNO
AMNO:  Assignment of Monitored Number
12. Functions
This command is used to assign/delete Monitored Numbers.
13. Precaution
Monitored Number (MON) is a number of maximum 5 digits consisting of 0 ~ 9, “*” and “#”. 
Note that, in the case of a hotel system, UCD Pilot Number (STN) is a number of maximum 6 digits,
respectively.
As NMI value, use a different value for each MON to be assigned.
14. Parameters
TN : Tenant Number
MNO : Monitored Number...

Page 45

ND-70895 (E) CHAPTER 4
 Page 35
Revision 1.0
COMMANDS
AMNO
Monitored Number Assignment Table
Note 1:Max. 6 digits when using in a hotel system
Note 2:Data to be entered for a hotel system
Going by UCD when monitored status is not requested from AP :0/1 = Not Going By UCD/Going By UCD.
TENANT 
NUMBER
(TN)MONITORED 
NUMBER
 (MNO)
MAX. 5 DIGITS
(
Note 1)MONITORED 
NUMBER INDEX
(NMI)
1 ~ 4095GOING BY UCD WHEN 
MONITOR 
STATUS IS NOT 
REQUESTED FROM 
AP
(UCD)
0/1UCD PILOT 
NUMBER
(STN)
MAX. 5 DIGIT
(Note...

Page 46

CHAPTER 4 ND-70895 (E)
Page 36
Revision 1.0
COMMANDS
AOAC
AOAC:  Assignment of OAI Access Code
16. Functions
This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each service
access code of the OAI System.
17. Precaution
(a) When setting a minus value (less than 0) to the parameter “OP-CODE”, add “-” (minus symbol) 
ahead to the value.
If the set value is a positive value, it is automatically interpreted to be a positive value even if “+” 
(plus symbol) is not...

Page 47

ND-70895 (E) CHAPTER 4
 Page 37
Revision 1.0
COMMANDS
AOAC
OAI Access Code Data Assignment Table
Note:The number of digits for OAI Access Codes is to be set by AOKC command.
OAI ACCESS CODE
(MAX 3 DIGITS)
(OAI-ACC)FACILITY KIND
(1/2)
(F-KIND)OPERATION CODE
128 ~ 255
(OP-CODE) 

Page 48

CHAPTER 4 ND-70895 (E)
Page 38
Revision 1.0
COMMANDS
AOKC
AOKC:  Assignment of OAI Key Code
20. Functions
This command is used to assign/delete the Facility Kind and the Operation Code on a basis of each function
key on the D
term.
21. Precaution
(a) The OAI code for which F-KIND = 3 (Open Application Interface) can be assigned is only one per 
system.
(b) When deleting the Open Application Interface (OAI) key code for which F-KIND = 3 is assigned, it 
is necessary, in advance to the intended deletion,...

Page 49

ND-70895 (E) CHAPTER 4
 Page 39
Revision 1.0
COMMANDS
AOKC
Note 1:
The relationship between this parameter and the AKYD command parameter FKY = 34 ~ 47 is shown
below.
Note 2:Enter this parameter only when F-KIND = 3.
Note 3:This parameter can be entered only when F-KIND = 1, 2. The range of the values that can be entered is as
follows:
F-KIND = 1: OP-CODE = 128 ~ 191
F-KIND = 2: OP-CODE = 192 ~ 255
23. Related Commands
List Up: LOKC
PARAMETER KEY CODEAKYD COMMAND 
PARAMETER FKY
1
2
3
4
5
6
7
8
9
10
11...

Page 50

CHAPTER 4 ND-70895 (E)
Page 40
Revision 1.0
COMMANDS
AOKC
OAI Key Code Data Assignment Table
Note 1:This parameter is to be entered only when F-KIND = 3.
Note 2:This parameter is to be entered only when F-KIND = 1, 2.
Note 3:The KEY-CODE for which F-KIND = 3 can be assigned is only one per system.
Note 4:When deleting a Key-Code assigned on F-KIND = 3, it is necessary to delete all the Key-Code data before-
hand by Assignment of OAI Access Code Data (AOAC) command.
OAI KEY CODE
(1 ~ 31)...