Page 61

ND-70895 (E) CHAPTER 4
 Page 51
Revision 1.0
COMMANDS
ASYD
System Data Assign Table (1)
SYSTEM
DATA
TYPE
(SYS)SYSTEM 
DATA  
INDEX 
(INDEX)
0 – 255DATA
(DATA)
00– FF
(Hex)BIT 
CORRE-
SPONDING 
DATA SYSTEM DATA CONTENTS
DATA
0/1BIT
449b
0SCF Call origination from the first party notification
0/1 = Ineffective/Effective
b
1Not used
b
2Access to Announcement trunk is controlled:
0 = by the timer, 1 = by the DAT
b
3Output pattern of INS information by SMFN
0/1: HEX/ASCII
b
4
Not used b5
b6
b7 

Page 62

CHAPTER 4 ND-70895 (E)
Page 52
Revision 1.0
COMMANDS
ASYD
System Data Assign Table (3)
SYSTEM 
DATA  
TYPE
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 255DATA
(DATA)
00– FF
(Hex)BIT 
CORRE-
SPONDING 
DATA SYSTEM DATA CONTENTS
DATA
0/1BIT
315b
0Designation of the initial mode of the card reader
000: PB Sender 100
001: LP Command   : Not used
010: – 111
011: Data channel b
1
b2
0b3
Not used 0b
4
0b5
0b6
0b7
~ 

Page 63

ND-70895 (E) CHAPTER 4
 Page 53
Revision 1.0
COMMANDS
DFLN
DFLN:  Display of Location Free Numbering
29. Functions
This command is used to check the assigned data of Location Free Numbering Service. When this
command is activated, the assigned data are displayed on a basis of each designated station number.
30. Precaution
The data to be displayed by this command are those assigned from the User Application Processor (UAP)
and thus they cannot be assigned by a command.
31. Parameters
[Input Parameters]
F...

Page 64

CHAPTER 4 ND-70895 (E)
Page 54
Revision 1.0
COMMANDS
ASYDN
ASYDN:  Assignment of System Data in NDM
33. Function
This command is used to assign system data 1 and 2.
34. Precautions
1. This section only explains about ASYDN command for OAI system.
2. For more details of ASYDN command, see the “Office Data Specification.”
35. Parameters
Refer to the following page. 

Page 65

ND-70895 (E) CHAPTER 4
 Page 55
Revision 1.0
COMMANDS
ASYDN
Note 1:
When the all Fusion nodes in the network are used for “MULTIPLE IPs”, this data may be assigned using
ASYDN.
Note 2:Available since the Series 7400 (Release 8) software.
SYSTEM 
DATA  
TYPE
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 1535DATA
(DATA)
00 – FF
(Hex)BIT 
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS (MDATA)
DATA
0/1BIT
1514 01b
0Network Data Memory (NDM) usage. Assign 
data “1 (the memory block is used)” for the 
corresponding memory...

Page 66

CHAPTER 4 ND-70895 (E)
Page 56
Revision 1.0
COMMANDS
ASYDL
ASYDL:  Assignment of System Data into Local DM (LDM)
36. Function
This command is used to assign and change system data for OAI activated via FCCS.
37. Precautions
ASYDL command is comprised with System Data-1, INDEX 512-1535.
This section only explains about ASYDL command for OAI System.
38. Parameters
Refer to the following pages. 

Page 67

ND-70895 (E) CHAPTER 4
 Page 57
Revision 1.0
COMMANDS
ASYDL
SYSTEM
DATA
TYPE 
(SYS)SYSTEM
DATA
INDEX
(INDEX)
512-1535DATA 
(DATA) 
00 – FF 
(Hex)BIT
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
1512b
0Fusion Point Code (FPC) of self node in hexadecimal.
FPC 1-253 (01 Hex-FD Hex)
Note:After assigning/changing the FPC, System Initialization (Non-
Load Initialization) is required.  b
1
b2
b3
b4
b5
b6
b7
513 01b
0Local Data Memory (LDM) usage. Assign data “1 (the memory block 
is used)” for the...

Page 68

CHAPTER 4 ND-70895 (E)
Page 58
Revision 1.0
COMMANDS
ASYDL
1523Default Gateway Address of External LAN
Gateway Address (IP address of Router) of Network connecting PBX.
Note:This data is valid when the PBX is connected to the external
PC LAN.
In the case of no Network Gateway, assignment data is 00 Hex.
in Index 523 through 526.
Example:
Default Gateway Address : 133.206.8.254
524
525
526
SYSTEM
DATA
TYPE 
(SYS)SYSTEM
DATA
INDEX
(INDEX)
512-1535DATA 
(DATA) 
00 – FF 
(Hex)BIT
CORRESPONDING 
DATA
SYSTEM...

Page 69

ND-70895 (E) CHAPTER 5
Page 59
Revision 1.0
CHAPTER 5 OFFICE DATA DESIGN
1. General
This chapter explains the procedure for setting the office data required in the NEAX2400 IMX OAI System. As
for the office data setting procedure of the NEAX2400 IMX System itself, refer to the System Data Design
Manual.
The description of this Chapter consists of the following contents.
 Procedure for Setting Basic Office Data for OAI System
This section explains the procedure for setting the basic office data of the...

Page 70

CHAPTER 5 ND-70895 (E)
Page 60
Revision 1.0
OFFICE DATA DESIGN
Procedure for Setting Basic Office Data for OAI System
2. Procedure for Setting Basic Office Data for OAI System
The procedure for setting the office data for OAI system is explained in the following.
2.1 Data for OAI System
1. ASYD/ASYDL
ASYD-SYS1 INDEX31 - b0 ~ 3 : CM mounting capacity (Normally Assign “04”.)
INDEX79 - b6 = 0 (OAI service is in service)
INDEX207 - b0 (IP in system 0), b1 (IP in system 1)
Assign “1” to the corresponding bit...