Page 347
FX Access F-2
Interactions (cont’d)
6. When the system is in the night mode of operation, incoming FX calls can be answered using NIGHT
CONNECTION - FIXED [N-1], FLEXIBLE [N-2] or TRUNK ANSWER FROM ANY STATION [T-8]
feature.
7. DIRECT INWARD DIALING [D-8] is not provided for FX trunks. All calls are normally routed to the
Attendant, UCD group, or a CAS Attendant.
8. Outgoing FX trunk calls can be restricted from preselected stations...

Page 392

NEAX2400 IMX Feature Programming Manual
Page 348ND-70184 (E), Issue 3
F-3D Flash Button - Dterm
F-3D Flash Button - Dterm
General Description
This feature provides for a Dterm set to program one of the programmable line/feature keys to function as a FLASH
BUTTON. The FLASH BUTTON will function in the manner a switch hook flash does for a single-line set.
Operating Procedure
When activating features common to both Dterm and single-line sets:
1. Press the FLASH BUTTON to receive special dial tone,
2. Dial...

Page 393

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 349
Flash Button - DtermF-3D
Programming (cont’d)
STEP 2:ADSL - SN=5 (Consultation Hold) and FKY=21 (Flash Button; FLASH).
This command is used for assigning the function to each soft key. 

Page 394

NEAX2400 IMX Feature Programming Manual
Page 350ND-70184 (E), Issue 3
F-4D Flash Entry - Dterm
F-4D Flash Entry - Dterm
General Description
This feature allows a Dterm user to insert a switch hook flash as the first digit in a stored SPEED CALLING-ONE
TOUCH-Dterm [S-26D] number.
Operating Procedure
To add a flash to a stored SPEED CALLING-ONE TOUCH-Dterm [S-26D] number to a Dterm: 
1. Stay on-hook.
2. Press the Feature key and the SPEED CALLING-ONE TOUCH-D
term [S-26D] key; the LCD display will
either be...

Page 395

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 351
Flash Entry - DtermF-4D
Service Conditions (cont’d)
2. A FLASH ENTRY, stored as a flash, may be used only once, unless digits are dialed between use.
Interactions
Refer to the NEAX2400 IMX Office Data Specification, ASYD, System Data 3, Index 2 for programming the
characteristics of a switch hook.
Programming
This is a Dterm feature. It is inherent to the instrument and requires no programming via the MAT. 

Page 396

NEAX2400 IMX Feature Programming Manual
Page 352ND-70184 (E), Issue 3
F-5D Flexible Ringing Assignment - Dterm
F-5D Flexible Ringing Assignment - Dterm
General Description
This feature enables Dterm line appearances to be individually programmed for ringing, not ringing, ringing (day
only), or ringing (night only).
Operating Procedure
No manual operation is required once FLEXIBLE RINGING ASSIGNMENT has been programmed in System
Data.
Service Conditions
1. Recall ringing supersedes all ringing...

Page 397

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 353
Flexible Ringing Assignment - DtermF-5D
Programming (cont’d)
RG: Ringing Assignment per Multi-line Appearance
0: No Ringing.
1: Ringing in Day Mode Only.
2: Ringing in Night Mode Only.
3: Ringing Day and Night. 

Page 398

NEAX2400 IMX Feature Programming Manual
Page 354ND-70184 (E), Issue 3
F-6 Faulty Trunk Report
F-6 Faulty Trunk Report
General Description
This feature allows a station to report a noisy or faulty trunk number by dialing a special access code before hanging
up. The FAULTY TRUNK REPORT consists of a trunk number, telephone number, associated time division switch
and reported time. This information is displayed at the MAINTENANCE ADMINISTRATION TERMINAL
(MAT) [M-18] and/or system printer.
Operating...

Page 399

NEAX2400 IMX Feature Programming Manual
ND-70184 (E), Issue 3
Page 355
Forced Account Code F-7
F-7 Forced Account Code
General Description
This feature is a variation of the ACCOUNT CODE [A-18] feature, which makes it mandatory to enter an
ACCOUNT CODE (up to 10 digits) for all outgoing calls. The account code must be dialed before dialing the
outgoing number. Calls are processed only when the dialed account code is valid.
The FORCED ACCOUNT CODE can be masked on the D
term display if necessary using the...

Page 400

NEAX2400 IMX Feature Programming Manual
Page 356ND-70184 (E), Issue 3
F-7 Forced Account Code
Service Conditions (cont’d)
Note:
There are two methods of FORCED ACCOUNT CODE assignment. These methods are Full Implementation and the
Check Sum method. In the Full Implementation method, the whole FORCED ACCOUNT CODE is assigned in the
AATC command and System Data 1, Indexes 12, 13, & 14 are assigned 00H. In the Check Sum method, partial
assignment for each FORCED ACCOUNT CODE is assigned in the AATC command....