    							 NEAX2000 IVS2 Office Data Programming ManualPage 68  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    128
    129
    130
    131
    132
    133
    134
    135
    136
    137
    138
    139
    140
    141
    142
    143
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 69
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    128
    129
    130
    131
    132
    133
    134
    135
    136
    137
    138
    139
    140
    141
    142
    143
    INITIALINITIAL
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 70  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM10 CM12
    STATION No.
    TRUNK No.
    CARD No.
    (1-10 DIGITS)YY
    00 01 02 03 04 05 07 11 12 13 16
    DAY NIGHT A B00
    1500
    630/100
    150
    3x
    xxxx00
    15D000
    D255
    3 1 115151501 1 15 3NONE15NONE
    144
    145
    146
    147
    148
    149
    150
    151
    152
    153
    154
    155
    156
    157
    158
    1591
    3
    ~~ ~ ~ ~ ~~ ~1
    8~1
    8~00
    15~00
    15~
    SETTING DATA
    (1-10 digits) LEN
    (3 digits)STEXE ++ +
    10+DE
    + +DE
    COMMAND 10:
    STATION No.
    (1-8 digits)
    STEXE ++ +
    12YYSETTING DATA
    (1-4 digits) +DE
    + +DE
    COMMAND 12:
    CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 71
    : Initial Data
    LEN
    CM12
    YY
    17
    19 22 23 24
    0, 1, 3X
    XXXXXXXX0/10
    30/7
    3NONE037
    144
    145
    146
    147
    148
    149
    150
    151
    152
    153
    154
    155
    156
    157
    158
    159
    INITIAL
    ~ ~
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 72  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    144
    145
    146
    147
    148
    149
    150
    151
    152
    153
    154
    155
    156
    157
    158
    159
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 73
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    144
    145
    146
    147
    148
    149
    150
    151
    152
    153
    154
    155
    156
    157
    158
    159
    INITIALINITIAL
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 74  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM10 CM12
    STATION No.
    TRUNK No.
    CARD No.
    (1-10 DIGITS)YY
    00 01 02 03 04 05 07 11 12 13 16
    DAY NIGHT A B00
    1500
    630/100
    150
    3x
    xxxx00
    15D000
    D255
    3 1 115151501 1 15 3NONE15NONE
    160
    161
    162
    163
    164
    165
    166
    167
    168
    169
    170
    171
    172
    173
    174
    1751
    3
    ~~ ~ ~ ~ ~~ ~1
    8~1
    8~00
    15~00
    15~
    SETTING DATA
    (1-10 digits) LEN
    (3 digits)STEXE ++ +
    10+DE
    + +DE
    COMMAND 10:
    STATION No.
    (1-8 digits)
    STEXE ++ +
    12YYSETTING DATA
    (1-4 digits) +DE
    + +DE
    COMMAND 12:
    CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 75
    : Initial Data
    LEN
    CM12
    YY
    17
    19 22 23 24
    0, 1, 3X
    XXXXXXXX0/10
    30/7
    3NONE037
    160
    161
    162
    163
    164
    165
    166
    167
    168
    169
    170
    171
    172
    173
    174
    175
    INITIAL
    ~ ~
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 76  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    160
    161
    162
    163
    164
    165
    166
    167
    168
    169
    170
    171
    172
    173
    174
    175
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 77
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    160
    161
    162
    163
    164
    165
    166
    167
    168
    169
    170
    171
    172
    173
    174
    175
    INITIALINITIAL
    CM10, 12, 13 
    						
    All NEC manuals Comments (0)