    							 NEAX2000 IVS2 Office Data Programming ManualPage 8  ND-70931 (E), Issue 2.0
    CHAPTER 1  CUSTOMIZING OFFICE DATA
    How to Customize Office Data
     NUMBER OF LINE
    Specify the number of trunks to be provided with each route Incoming (IC), Outgoing (OG), 
    Bothway (BW)
    DP/PB
    Specify the type of address signal from/to distant office, as follows:
       TYPE OF TEL  
           DESCRIPTION       
    DP  . . . . . . . . . . . . .  Dial Pulse
    PB  . . . . . . . . . . . . .  DTMF Signal
     KIND OF SIGNAL
    Specify the kind of signaling system such as Ring Down, Loop, E & M, etc. at the line.
    Station Hunting Group Data
    In Station Hunting Group Data Table (Table 1-4), the following data is required:
     KIND OF STATION HUNTING
    Specify the kind of the Station Hunting System (Pilot/Circular/Switch Back). 
    For the Pilot System, specify the Pilot Station number.
     SECRETARY STATION
    Specify the Secretary Station number, if provided.
     STATION NUMBER
    Specify the station numbers to be assigned to the Station Hunting Group with the following 
    conditions.
    (1) Up to 60 stations can be assigned per Station Hunting Group.
    (2) There is no limitation to the number of Station Hunting Group.
    (3) The same one station cannot be assigned to multiple Hunting Groups. 
    						
    							CHAPTER 1  CUSTOMIZING OFFICE DATA
    How to Customize Office Data
    NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 9
    Call Pickup Group Data
    Assign station number to the Call Pickup Group with the following conditions (Table 1-5):
    (1) Up to 60 stations can be assigned per Call Pickup Group.
    (2) There are no limitations to the number of Call Pickup Groups.
    (3) The same one station cannot be assigned to plural Call Pickup Groups.
    Speed Calling-System Data
    This data table (Table 1-6) requires the abbreviated code and the stored number to be sent out.
    A maximum of 32 digits stored number can be assigned.
    Port Assignment
    Specify the station number or trunk number corresponding to the Line Equipment Number (LEN)
    (Table 1-7). For port assignment of each line/trunk card, refer to the Command Manual (CM10). 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 10  ND-70931 (E), Issue 2.0
    CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    CUSTOMER SPECIFICATIONS SHEET
    This section provides the following sheets for designing the customer specifications of the PBX.
     Numbering Plan Data Table
     Station Data Table 
     Trunk Data Table
     Station Hunting Group Data Table
     Call Pickup Group Data Table
     Speed Calling-System Data Table
     Port Assignment Table
    According to customer’s requirements, the installer should complete the following sheets by
    referring to the “Resident System Program” Chapter in the Command Manual and How to
    Customize Office Data on Page 6. 
    						
    							CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 11
    NOTE:If space is insufficient, use copies.
    Table 1-1  Numbering Plan Data Table
    ACCESS CODE FUNCTIONS REMARKS
    Numbering Plan Group PROGRAMMING:  CM20, 21 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 12  ND-70931 (E), Issue 2.0
    CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NOTE:If space is insufficient, use copies.
    Table 1-2  Station Data Table
    STATION
    NUMBERTYPE OF 
    TEL.SERVICE CLASS RESTRICTION CLASS DIT 
    TRUNK 
    NUMBERREMARKS
    A B C DAY NIGHT
    Department or Section Tenant PROGRAMMING:
    CM10,11,12,13,15 
    						
    							CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 13
    NOTE:If space is insufficient, use copies.
    Table 1-3  Trunk Data Table
    ACCESS 
    NUMBERDESTINATIONKIND OF 
    TRUNKTYPE OF 
    TRUNKNUMBER 
    OF LINEDP/PBKIND OF 
    SIGNALREMARKS
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    IC
    OG
    BW
    PROGRAMMING:  CM10, 30, 35, 36 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 14  ND-70931 (E), Issue 2.0
    CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NOTE:If space is insufficient, use copies.
    Table 1-4  Station Hunting Group Data Table
    KIND OF STATION 
    HUNTINGKIND OF STATION 
    HUNTINGKIND OF STATION 
    HUNTINGKIND OF STATION 
    HUNTING
    Pilot (        ) Pilot (        ) Pilot (        ) Pilot (        )
    Circular Circular Circular Circular
    Switch Back Switch Back Switch Back Switch Back
    SECRETARY 
    STATIONSECRETARY 
    STATIONSECRETARY 
    STATIONSECRETARY 
    STATION
    SECRETARY 
    NUMBERSECRETARY 
    NUMBERSECRETARY 
    NUMBERSECRETARY 
    NUMBER
    PROGRAMMING:  CM18 
    						
    							CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 15
    NOTE:If space is insufficient, use copies.
    Table 1-5  Call Pickup Group Data Table
    STATION
    NUMBERSTATION
    NUMBERSTATION
    NUMBERSTATION
    NUMBER
    PROGRAMMING:  CM16 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 16  ND-70931 (E), Issue 2.0
    CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NOTE:If space is insufficient, use copies.
    Table 1-6  Speed Calling-System Data Table
    ABBREVIATED
    CODESENDING NUMBER REMARKS
    PROGRAMMING:  CM71, 72 
    						
    							CHAPTER 1  CUSTOMIZING OFFICE DATA
    Customer Specifications Sheet
    NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 17
    Table 1-7  Port Assignment Table (1 of 3)
    LEN
    FILL IN THE STATION NO./TRUNK NO.
    LT SLOT NO.
    [PIM2]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    207 215 223 231 239 247 255 263
    206 214 222 230 238 246 254 262
    205 213 221 229 237 245 253 261
    204 212 220 228 236 244 252 260
    203 211 219 227 235 243 251 259 239 247 255 263
    202 210 218 226 234 242 250 258 238 246 254 262
    201 209 217 225 233 241 249 257 237 245 253 261
    200 208 216 224 232 240 248 256 236 244 252 260
    [PIM1]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    107 115 123 131 139 147 155 163
    106 114 122 130 138 146 154 162
    105 113 121 129 137 145 153 161
    104 112 120 128 136 144 152 160
    103 111 119 127 135 143 151 159 139 147 155 163
    102 110 118 126 134 142 150 158 138 146 154 162
    101 109 117 125 133 141 149 157 137 145 153 161
    100 108 116 124 132 140 148 156 136 144 152 160
    [PIM0]
    LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11
    007 015 023 031 039 047 055 063
    006 014 022 030 038 046 054 062
    005 013 021 029 037 045 053 061
    004 012 020 028 036 044 052 060
    003 011 019 027 035 043 051 059 039 047 055 063
    002 010 018 026 034 042 050 058 038 046 054 062
    001 009 017 025 033 041 049 057 037 045 053 061
    000 008 016 024 032 040 048 056 036 044 052 060 
    						