    							 NEAX2000 IVS2 Office Data Programming ManualPage 378  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    CM77 CM77
    Y
    0
    3STATION/TRUNK 
    NAME No.SETTING DATA Y
    0
    3STATION/TRUNK 
    NAME No.SETTING DATA
    CHARACTER CODE CHARACTER CODE
    ~
    ~
    STEXE ++ ++ 77YDESETTING DATA STATION No.
    +DE
    COMMAND 77:+ TRUNK NAME No. /
    (1-8 digits) (2 digits) (1-32 digits) CM77 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 379
    NOTE:If space is insufficient, use copies.
    CM78
    1ST DATA 2ND DATA
    TENANT
    NUMBER
    (00-63)BLOCK
    NUMBER
    (0-7)WHEN
    DESTINATION
    IS A STATIONWHEN DESTINATION IS AN OUTSIDE PARTY
    STATION NUMBER
    (1-8 DIGITS)TRUNK ACCESS
    CODE (1/2 DIGITS)SEPARATOR
    MARKCALLED NUMBER (MAX. 26 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ST
    ++ ++ 78DE
    +DE
    COMMAND 78:1ST DATA
    (3 digits)2ND DATA
    (1-29 digits)+EXECM78 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 380  ND-70931 (E), Issue 2.0
    DATA 0: Restricted
    3: Allowed
    :  Initial Data
    CM81
    TRUNK RESTRICTION CLASSYY
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    1 RCA 3033300033333030
    2 RCB 3033000033000030
    3 RCC 3030000030000030
    4 RCD 3000000000000030
    5 RCE 3000000000000030
    6 RCF 0000000000000030
    7 RCG 0000000000000030
    8 RCH 0000000000000030
    CM81
    TRUNK RESTRICTION CLASSYY
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
    01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00
    1 RCA030
    2 RCB030
    3 RCC030
    4 RCD030
    5 RCE030
    6 RCF030
    7 RCG030
    8 RCH030
    STEXE ++ ++
    81YYDESETTING DATA TRUNK RESTRICTION
    +DE
    COMMAND 81:+
    CLASS
    (1 digit)(1 digit) CM81 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 381
    CM85 CM85
    YAREA/OFFICE CODE
    (MAX. 8 DIGITS)MAX.
    No. OF 
    SENDING 
    DIGITSYAREA/OFFICE CODE
    (MAX. 8 DIGITS)MAX.
    No. OF 
    SENDING 
    DIGITS
    STEXE ++ ++
    85YDEMAX. No. OF AREA/
    +DE
    COMMAND 85:+
    SENDING DIGITS
    (2 digits) (1-8 digits) OFFICE CODECM85 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 382  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    CM8A CM8A
    YYYY 1ST DATA 2ND DATA YYYY 1ST DATA 2ND DATA
    STEXE ++ ++
    8A YYYYDE2ND DATA 1ST DATA
    +DE
    COMMAND 8A:+
    (1-8 digits) (1-5 digits) CM8A 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 383
    Dterm
    NOTE:If space is insufficient, use copies.
    NOTE:When using Key No. 17-24, set CM12 Y=24, 2nd data to 0.
    :  Initial Data
    CM90
    MY LINE NUMBER
       KEY NUMBERYY
    00 01 03 05 00 01 03 05
    111 111
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    90 F1015 F1015
    91 F1011 F1011
    92 F1012 F1012
    93 F1000 F1000
    94 F1016 F1016
    95
    96 F1004 F1004
    97 F1010 F1010
    STEXE ++ ++
    90YYDESETTING DATA MY LINE
    +DE
    COMMAND 90:+ KEY
    ++,
    No.
    (1-8 digits)NUMBER
    (01-24, 90-97)(1-8 digits)CM90 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 384  ND-70931 (E), Issue 2.0
    Dterm
    NOTE:If space is insufficient, use copies.
    NOTE:When using Key No. 17-24, set CM12 Y=24, 2nd data to 0.
    :  Initial Data
    CM90
    YY
    00 01 03 05 00 01 03 05 00 01 03 05
    111 111 111
    CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 385
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    MY LINE NUMBER
       KEY NUMBERYY
    00 01 03 00 01 03
    11 11
    30
    31
    32
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    SETTING DATA
    (1-8 digits)STEXE ++ +
    90YYDEMY LINE
    +DE COMMAND 90:
    + ADD-ON
    +,
    No.
    (1-8 digits)MODULE
    KEY No.
    (30-89) ++CM90 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 386  ND-70931 (E), Issue 2.0
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    YY
    00 01 03 00 01 03 00 01 03
    11 11 11
    CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 387
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    MY LINE NUMBER
       KEY NUMBERYY
    00 01 03 00 01 03
    11 11
    50
    51
    52
    53
    54
    55
    56
    57
    58
    59
    60
    61
    62
    63
    64
    65
    66
    67
    68
    69
    SETTING DATA
    (1-8 digits)STEXE ++ +90YYDEMY LINE
    +DE COMMAND 90:
    + ADD-ON
    +,
    No.
    (1-8 digits)MODULE
    KEY No.
    (30-89) ++CM90 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Office Data Programming Manual