Home > NEC > Communications System > NEC Neax 2000 Ivs2 Office Data Programming Manual

NEC Neax 2000 Ivs2 Office Data Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Office Data Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 475
    							 NEAX2000 IVS2 Office Data Programming ManualPage 188  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    608
    609
    610
    611
    612
    613
    614
    615
    616
    617
    618
    619
    620
    621
    622
    623
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 189
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    608
    609
    610
    611
    612
    613
    614
    615
    616
    617
    618
    619
    620
    621
    622
    623
    INITIALINITIAL
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 190  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM10 CM12
    STATION No.
    TRUNK No.
    CARD No.
    (1-10 DIGITS)YY
    00 01 02 03 04 05 07 11 12 13 16
    DAY NIGHT A B00
    1500
    630/100
    150
    3x
    xxxx00
    15D000
    D255
    3 1 115151501 1 15 3NONE15NONE
    624
    625
    626
    627
    628
    629
    630
    631
    632
    633
    634
    635
    636
    637
    638
    6391
    3
    ~~ ~ ~ ~ ~~ ~1
    8~1
    8~00
    15~00
    15~
    SETTING DATA
    (1-10 digits) LEN
    (3 digits)STEXE ++ +
    10+DE
    + +DE
    COMMAND 10:
    STATION No.
    (1-8 digits)
    STEXE ++ +
    12YYSETTING DATA
    (1-4 digits) +DE
    + +DE
    COMMAND 12:
    CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 191
    : Initial Data
    LEN
    CM12
    YY
    17
    19 22 23 24
    0, 1, 3X
    XXXXXXXX0/10
    30/7
    3NONE037
    624
    625
    626
    627
    628
    629
    630
    631
    632
    633
    634
    635
    636
    637
    638
    639
    INITIAL
    ~ ~
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 192  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    624
    625
    626
    627
    628
    629
    630
    631
    632
    633
    634
    635
    636
    637
    638
    639
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 193
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    624
    625
    626
    627
    628
    629
    630
    631
    632
    633
    634
    635
    636
    637
    638
    639
    INITIALINITIAL
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 194  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM10 CM12
    STATION No.
    TRUNK No.
    CARD No.
    (1-10 DIGITS)YY
    00 01 02 03 04 05 07 11 12 13 16
    DAY NIGHT A B00
    1500
    630/100
    150
    3x
    xxxx00
    15D000
    D255
    3 1 115151501 1 15 3NONE15NONE
    640
    641
    642
    643
    644
    645
    646
    647
    648
    649
    650
    651
    652
    653
    654
    6551
    3
    ~~ ~ ~ ~ ~~ ~1
    8~1
    8~00
    15~00
    15~
    SETTING DATA
    (1-10 digits) LEN
    (3 digits)STEXE ++ +
    10+DE
    + +DE
    COMMAND 10:
    STATION No.
    (1-8 digits)
    STEXE ++ +
    12YYSETTING DATA
    (1-4 digits) +DE
    + +DE
    COMMAND 12:
    CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 195
    : Initial Data
    LEN
    CM12
    YY
    17
    19 22 23 24
    0, 1, 3X
    XXXXXXXX0/10
    30/7
    3NONE037
    640
    641
    642
    643
    644
    645
    646
    647
    648
    649
    650
    651
    652
    653
    654
    655
    INITIAL
    ~ ~
    CM10, 12, 13 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 196  ND-70931 (E), Issue 2.0
    : Initial Data
    LEN
    CM13
    YY
    00 01 02 03 04 05 06 07 08 09 10 12 13 14 15 18 21 22
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111111111111111111
    640
    641
    642
    643
    644
    645
    646
    647
    648
    649
    650
    651
    652
    653
    654
    655
    STATION No.
    (1-8 digits)STEXE ++ +13YYSETTING DATA
    (1 digit) +DE
    + +DE
    COMMAND 13: CM10, 12, 13 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 197
    : Initial Data
    LEN
    CM13
    YY
    23 24 25 28 29 32 33 34 35 36 37 39
    0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
    111 1 11 1 11111
    640
    641
    642
    643
    644
    645
    646
    647
    648
    649
    650
    651
    652
    653
    654
    655
    INITIALINITIAL
    CM10, 12, 13 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Office Data Programming Manual