Home > NEC > Communications System > NEC Neax 2000 Ivs2 Office Data Programming Manual

NEC Neax 2000 Ivs2 Office Data Programming Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Office Data Programming Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 475
    							 NEAX2000 IVS2 Office Data Programming ManualPage 368  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    Y=0
    CM72 Y=0
    MEMORY 
    SLOT 
    NUMBER
    (000-299)STORED NUMBER
    ACCESS CODESEPARATOR 
    MARKCALLED PARTY No.
    (MAX. 26 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    STEXE ++ ++
    720DESTORED No. MEMORY SLOT
    +DE
    COMMAND 72:+
    No. (000-299) (Max. 32 digits) CM72 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 369
    NOTE:If space is insufficient, use copies.
    Y=0
    CM72 Y=0
    MEMORY 
    SLOT 
    NUMBER
    (000-299)STORED NUMBER
    ACCESS CODESEPARATOR 
    MARKSTATION No.
    (MAX. 8 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    STEXE ++ ++
    720DESTORED No. MEMORY SLOT
    +DE
    COMMAND 72:+
    No. (000-299) (Max. 32 digits)CM72 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 370  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    Y=1, 2
    CM72
    MEMORY 
    SLOT 
    NUMBER
    (000-299)STORED NUMBER
    Y=1 Y=2
    STATION NAME CHARACTER CODE
    (MAX. 32 DIGITS: 16 CHARACTERS)STATION NAME CHARACTER
    (MAX. 16 CHARACTERS)
    STEXE ++ ++ 72YDESTORED No.
    MEMORY SLOT
    +DE
    COMMAND 72:+
    No. (000-299)(Max. 32 digits:
    16 Characters) CM72 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 371
    NOTE:If space is insufficient, use copies.
    CM73
    STATION
    NUMBERSETTING DATA
    1000-SLOT
    MEMORY 
    BLOCK
    (0-3: BASIC, 
    4-9: OPTION)10-SLOT
    MEMORY START 
    BLOCK
    (00-99)POSSIBLE/NOT 
    POSSIBLE OF 
    REGISTRATION
    (0/1)NUMBER OF
    10-SLOT
    MEMORY 
    BLOCK
    (01-10)
    STEXE ++ ++
    73DESETTING DATA STATION No.
    +DE
    COMMAND 73:+
    (1-8 digits) (6 digits)CM73 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 372  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    Y=0
    CM74 Y=0
    MEMORY SLOT NUMBER STORED NUMBER
    1000-SLOT 
    MEMORY 
    BLOCK
    (0-3: BASIC, 
    4-9: OPTION)10-SLOT 
    MEMORY 
    BLOCK
    (00-99)MEMORY
    PARCEL
    (0-9)ACCESS 
    CODE (MAX. 
    4 DIGITS)SEPARATOR 
    MARKCALLED PARTYS NUMBER 
    (MAX. 8 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    STEXE ++ ++ 740DESTORED No. MEMORY SLOT
    +DE
    COMMAND 74:+
    No. (4 digits) (Max. 32 digits) CM74 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 373
    NOTE:If space is insufficient, use copies.
    Y=0
    CM74 Y=0
    MEMORY SLOT NUMBER STORED NUMBER
    1000-SLOT 
    MEMORY 
    BLOCK
    (0-3: BASIC, 
    4-9: OPTION)10-SLOT 
    MEMORY 
    BLOCK
    (00-99)MEMORY
    PARCEL
    (0-9)ACCESS 
    CODE (MAX. 
    4 DIGITS)SEPARATOR 
    MARKSTATION NUMBER 
    (MAX. 8 DIGITS)
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    ,
    STEXE ++ ++ 740DESTORED No. MEMORY SLOT
    +DE
    COMMAND 74:+
    No. (4 digits) (Max. 32 digits)CM74 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 374  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    Y=1, 2
    CM74
    MEMORY SLOT NUMBER STORED NUMBER
    1000-SLOT 
    MEMORY 
    BLOCK
    (0-3: BASIC, 
    4-9: OPTION)10-SLOT 
    MEMORY 
    BLOCK
    (00-99)MEMORY
    PARCEL
    (0-9)Y=1 Y=2
    STATION NAME
    CHARACTER CODE
    (MAX. 32 DIGITS: 
    16 CHARACTERS)STATION NAME CHARACTER
    (MAX. 16 CHARACTERS)
    STEXE ++ ++
    74YDESTORED No.
    MEMORY SLOT
    +DE
    COMMAND 74:+
    No. (4 digits)(Max. 32 digits:
    16 Characters) CM74 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 375
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM76 YY=00
    DID No.
    (1-4 DIGITS)NUMBER CONVERSION
    BLOCK (000-999)
    NONE
    STEXE ++ ++ 7600DENUMBER CONVERSION
    DID NUMBER
    +DE COMMAND 76:
    +
    BLOCK No. (000-999)
    (1-4 digits)CM76 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 376  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    CM76
    NUMBER
    CONVERSION
    BLOCK
    (000-999)YY
    01 02 03 04
    FOR DAY MODE
    (1-8 DIGITS)FOR NIGHT MODE
    (1-8 DIGITS)FOR MODE A 
    (1-8 DIGITS)FOR MODE B 
    (1-8 DIGITS)
    STEXE ++ ++
    76YYDESETTING DATA
    NUMBER CONVERSION
    +DE COMMAND 76:
    +
    (1-8 digits)
    BLOCK No. (1-3 digits) CM76 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 377
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM76
    NUMBER
    CONVERSION
    BLOCK
    (000-999)YY
    05 06 07 08 09 10 11 13
    TRK TN
    DAY
    MODE
    (00-63)TRK TN
    NIGHT
    MODE
    (00-63)TRK TN
    MODE A
    (00-63)TRK TN
    MODE B
    (00-63)STA. 
    TN
    (00-63)CALL
    WAITING
    (0/1)PRIORITY
    QUEUING
    (0/1)AUTO. 
    LIVE 
    REC. 
    (0/1)
    NONE NONE NONE NONE NONE 1 1 1
    STEXE ++ ++
    76YYDESETTING DATA
    NUMBER CONVERSION
    +DE COMMAND 76:
    +
    (1-8 digits)
    BLOCK No. (1-3 digits)CM76 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Office Data Programming Manual