NEAX2000 IVS2 Office Data Programming ManualPage 18 ND-70931 (E), Issue 2.0 CHAPTER 1 CUSTOMIZING OFFICE DATA Customer Specifications Sheet [PIM5] LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 507 515 523 531 539 547 555 563 506 514 522 530 538 546 554 562 505 513 521 529 537 545 553 561 504 512 520 528 536 544 552 560 503 511 519 527 535 543 551 559 539 547 555 563 502 510 518 526 534 542 550 558 538 546 554 562 501 509 517 525 533 541 549 557 537 545 553 561 500 508 516 524 532 540 548 556 536 544 552 560 [PIM4] LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 407 415 423 431 439 447 455 463 406 414 422 430 438 446 454 462 405 413 421 429 437 445 453 461 404 412 420 428 436 444 452 460 403 411 419 427 435 443 451 459 439 447 455 463 402 410 418 426 434 442 450 458 438 446 454 462 401 409 417 425 433 441 449 457 437 445 453 461 400 408 416 424 432 440 448 456 436 444 452 460 [PIM3] LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 307 315 323 331 339 347 355 363 306 314 322 330 338 346 354 362 305 313 321 329 337 345 353 361 304 312 320 328 336 344 352 360 303 311 319 327 335 343 351 359 339 347 355 363 302 310 318 326 334 342 350 358 338 346 354 362 301 309 317 325 333 341 349 357 337 345 353 361 300 308 316 324 332 340 348 356 336 344 352 360 Table 1-7 Port Assignment Table (2 of 3) LEN FILL IN THE STATION NO./TRUNK NO. LT SLOT NO.
CHAPTER 1 CUSTOMIZING OFFICE DATA Customer Specifications Sheet NEAX2000 IVS2 Office Data Programming Manual ND-70931 (E), Issue 2.0 Page 19 [PIM7] LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 707 715 723 731 739 747 755 763 706 714 722 730 738 746 754 762 705 713 721 729 737 745 753 761 704 712 720 728 736 744 752 760 703 711 719 727 735 743 751 759 739 747 755 763 702 710 718 726 734 742 750 758 738 746 754 762 701 709 717 725 733 741 749 757 737 745 753 761 700 708 716 724 732 740 748 756 736 744 752 760 [PIM6] LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 607 615 623 631 639 647 655 663 606 614 622 630 638 646 654 662 605 613 621 629 637 645 653 661 604 612 620 628 636 644 652 660 603 611 619 627 635 643 651 659 639 647 655 663 602 610 618 626 634 642 650 658 638 646 654 662 601 609 617 625 633 641 649 657 637 645 653 661 600 608 616 624 632 640 648 656 636 644 652 660 Table 1-7 Port Assignment Table (3 of 3) LEN FILL IN THE STATION NO./TRUNK NO. LT SLOT NO.
NEAX2000 IVS2 Office Data Programming ManualPage 20 ND-70931 (E), Issue 2.0 This page is for your notes.
NEAX2000 IVS2 Office Data Programming Manual ND-70931 (E), Issue 2.0 Page 21 CHAPTER 2 DATA PROGRAMMING SHEET This chapter contains the Office Data Sheets for programming the customer specifications in Chapter 1. For detailed information about the commands, refer to the Command Manual.
NEAX2000 IVS2 Office Data Programming ManualPage 22 ND-70931 (E), Issue 2.0 CHAPTER 2 DATA PROGRAMMING SHEET How to Read This Chapter HOW TO READ THIS CHAPTER The data programming sheets are given in numerical and alphabetical order of the command code. For programming procedure, see the CAT mode operation procedure below each data sheet. In each sheet, the following symbols are used. : Initial data which is automatically loaded into the memory, after system initialization by setting position “B” on SW3 of the MP, followed by a reset. : Commands that require a reset of the MP card after data setting. : Commands that require a reset of the AP00 card after data setting. : Commands that require a reset of the AP01 card after data setting. : Commands that require a reset of the DCH card after data setting. : Commands that require a reset of the DTI card after data setting. : Commands that require a reset of the DBM card after data setting. INITIAL AP00 INITIAL AP01 INITIAL DCH INITIAL DTI INITIAL DBM INITIAL
NEAX2000 IVS2 Office Data Programming Manual ND-70931 (E), Issue 2.0 Page 23 : Initial Data CM04 YY 1ST DATA 2ND DATA 00 00 7 00 00 : Initial Data CM05 CM05 AP NUMBERY AP NUMBERY 01 01 AP CARD TYPEAP HIGHWAY EXPANDED :0 BASIC :1AP CARD TYPEAP HIGHWAY EXPANDED :0 BASIC :1 NONE 1 NONE 1 04 20 05 21 06 22 07 23 08 24 09 25 10 26 11 27 12 28 13 29 14 30 15 31 INITIAL STEXE ++ ++ 04002ND DATADE 1ST DATA. (2 digits) (1 digit)+ +DE COMMAND 04: INITIALINITIAL STEXE ++ ++ 05YSETTING DATADE AP No. (2 digits) (2 digits)+ +DE COMMAND 05:CM04,05
NEAX2000 IVS2 Office Data Programming ManualPage 24 ND-70931 (E), Issue 2.0 YY=01 YY=04 CM06 YY=01 ATT No. AP No. CIRCUIT No. 0 1 2 3 4 5 6 7 CM06 YY = 04 MF/MFC/ CIR TRK No.AP No. CIRCUIT No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15INITIAL STEXE ++ +0601AP No. + CIRCUIT No. ATTCON No. (3 digits) + +DE +DE (1 digit) COMMAND 06: INITIAL STEXE ++ + 0604AP No. + CIRCUIT No. TRK No. (3 digits) + +DE +DE (2 digits) COMMAND 06: CM06
NEAX2000 IVS2 Office Data Programming Manual ND-70931 (E), Issue 2.0 Page 25 YY=07 YY=08 CM06 YY=07 CM06 YY=07 CCH No. AP No. IPT No. AP No. 00 11 22 33 44 55 66 77 CM06 YY=08 DCH No. AP No. 0 1 2 3 4 5 6 7INITIALINITIAL STEXE ++ + 0607AP No. CCH/IPT No. (1 digit) (2 digits) +DE + +DE COMMAND 06: INITIAL STEXE ++ + 0608AP No. DCH No. (1 digit) (2 digits) +DE + +DE COMMAND 06:CM06
NEAX2000 IVS2 Office Data Programming ManualPage 26 ND-70931 (E), Issue 2.0 YY=09 CM06 YY=09 ICH No. AP No. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 INITIAL STEXE ++ + ++ 0609DEICH No. +DE COMMAND 06:AP No. (2 digits) (2 digits) CM06
NEAX2000 IVS2 Office Data Programming Manual ND-70931 (E), Issue 2.0 Page 27 YY=10 CM06 YY=10 CM06 YY=10 AP No.D-CHANNEL BLOCK No.LEN OF CSI AP No.D-CHANNEL BLOCK No.LEN OF CSI 00 00 01 01 02 02 03 03 00 00 01 01 02 02 03 03 00 00 01 01 02 02 03 03 00 00 01 01 02 02 03 03 00 00 01 01 02 02 03 03 00 00 01 01 02 02 03 03 INITIALINITIALINITIAL STEXE ++ + ++ 0610DE +DE COMMAND 06:LEN AP No. OF CSI D-CHANNEL (4 digits) + BLOCK No. (3 digits)CM06