    							 NEAX2000 IVS2 Office Data Programming ManualPage 388  ND-70931 (E), Issue 2.0
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    YY
    00 01 03 00 01 03 00 01 03
    11 11 11
    CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 389
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    MY LINE NUMBER
       KEY NUMBERYY
    00 01 03 00 01 03
    11 11
    70
    71
    72
    73
    74
    75
    76
    77
    78
    79
    80
    81
    82
    83
    84
    85
    86
    87
    88
    89
    SETTING DATA
    (1-8 digits)STEXE ++ +
    90YYDEMY LINE
    +DE COMMAND 90:
    + ADD-ON
    +,
    No.
    (1-8 digits)MODULE
    KEY No.
    (30-89) ++CM90 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 390  ND-70931 (E), Issue 2.0
     Add-On Module
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90
    YY
    00 01 03 00 01 03 00 01 03
    11 11 11
    CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 391
     SN610/SN708/SN709/SN712/SN741 ATTCON
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90 YY=00
    ATTCON
    NUMBER
    KEY
    NUMBER
    01
    02
    03
    04
    05
    06 F6203
    07 F6240
    08 F6241
    09 F6242
    10 F6243
    11 F6244
    12 F6245
    13
    14
    15
    16 F6061
    17 F6060
    18 F6000
    90 F6200
    91 F6201
    92
    93
    94 F6204
    95 F6202
    96 (ANS)
    97 (RLS)
    SETTING DATA
    (5 digits)STEXE +++ + 9000DEATTCON No.
    +DE COMMAND 90:
    + ATTCON
    ++,
    (E000-E007)KEY No.
    (01-18, 90-97)CM90 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 392  ND-70931 (E), Issue 2.0
     SN610/SN708/SN709/SN712/SN741 ATTCON
    NOTE:If space is insufficient, use copies.
    CM90  YY=00
    MULTI-
    FUNCTION 
    KEY No.ATTCON STATUS No. (00-15) + ATTCON No. (0-7)
    01
    02
    03
    04
    05
    06
    CM90  YY=00
    MULTI-
    FUNCTION 
    KEY No.ATTCON STATUS No. (00-15) + ATTCON No. (0-7)
    01
    02
    03
    04
    05
    06
    STEXE ++ ++
    9000DESETTING
    EXXX+DE
    COMMAND 90:+ MULTI-FUNCTION
    ++,
    KEY No.
    (01-06)DATA
    (5 digits) CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 393
     SN716 DESKCON
    NOTE:If space is insufficient, use copies.
    :  Initial Data
    CM90  YY=00
    DESKCON
    NUMBER
    KEY
    NUMBER
    07 F6240
    08 F6241
    09 F6242
    10 F6243
    11 F6244
    12 F6245
    13 F6000
    14 F6040
    15 F6064
    16 F6060
    17 F6063
    18 F6061
    19
    20 F6150
    21
    22 F6066
    23 F6107
    24
    90 F6200
    91 F6201
    92
    93 F6203
    94 F6204
    95 F6202
    96 (Answer)
    97 (Release)
    SETTING DATA
    (5 digits)STEXE +++ + 9000DESN716 DESKCON
    +DE COMMAND 90:
    + SN716 DESKCON
    ++,
    No.
    (E000-E007)KEY No.
    (07-24, 90-97)CM90 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 394  ND-70931 (E), Issue 2.0
     SN716 DESKCON
    NOTE:If space is insufficient, use copies.
    CM90  YY=00
    MULTI-
    FUNCTION 
    KEY No.ATTCON STATUS No. (00-15) + ATTCON No. (0-7)
    01
    02
    03
    04
    CM90 YY=00
    MULTI-
    FUNCTION 
    KEY No.ATTCON STATUS No. (00-15) + ATTCON No. (0-7)
    01
    02
    03
    04
    STEXE ++ ++
    9000DESETTING
    EXXX+DE
    COMMAND 90:+ MULTI-FUNCTION
    ++,
    KEY No.
    (01-04)DATA
    (5 digits) CM90 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 395
    NOTE:If space is insufficient, use copies.
    CM93 CM93
    MY LINE NUMBER
    (1-8 DIGITS)STATION NUMBER
    (1-8 DIGITS)
    /TRUNK NUMBER
    (4 DIGITS)MY LINE NUMBER
    (1-8 DIGITS)STATION NUMBER
    (1-8 DIGITS)
    /TRUNK NUMBER
    (4 DIGITS)
    STEXE ++ ++ 93DETRUNK MY LINE
    +DE
    COMMAND 93:+
    No.
    (1-8 digits)No.
    (4 digits) STATION
    No.
    (1-8 digits)
    CM93 
    						
    							 NEAX2000 IVS2 Office Data Programming ManualPage 396  ND-70931 (E), Issue 2.0
    NOTE:If space is insufficient, use copies.
    CM94
    MY LINE
    NUMBERSETTING DATA
    1000-SLOT
    MEMORY BLOCK
    (0-3: BASIC, 
    4-9: OPTION)10-SLOT
    MEMORY START 
    BLOCK
    (00-99)POSSIBLE/NOT 
    POSSIBLE OF 
    REGISTRATION
    (0/1)QUANTITY OF
    10-SLOT
    MEMORY BLOCK
    (01-10)
    STEXE ++ ++
    94DESETTING DATA MY LINE
    +DE
    COMMAND 94:+
    No.
    (1-8 digits)(6 digits) CM94 
    						
    							NEAX2000 IVS2 Office Data Programming Manual    
    ND-70931 (E), Issue 2.0   Page 397
    CM96
    DSS CONSOLE 
    NUMBERSETTING DATA (1-8 DIGITS)DSS CONSOLE 
    NUMBERSETTING DATA (1-8 DIGITS)
    00 16
    01 17
    02 18
    03 19
    04 20
    05 21
    06 22
    07 23
    08 24
    09 25
    10 26
    11 27
    12 28
    13 29
    14 30
    15 31
    STEXE ++ ++
    96DESETTING DATA DSS CONSOLE
    +DE
    COMMAND 96:+
    No.
    (2 digits)(1-8 digits)CM96 
    						