Page 71
NDA-24219 CHAPTER 3 Page 57 Revision 2.0 NAP-200-007 Sheet 8/55 Termination of Cables on MDF * Major and minor alarm connections are used for external indications. Note 1:When LT04 or LT06 is mounted with an 8-port card, LT05 and/or LT07 must be vacant or mounted with a noninter- facing card. Note 2:2 wire type for Multiline Terminal/DSS Console/DESKCON. Note 3:4 wire type for Multiline Terminal/SN610 ATTCON. Note 4:When NEAXmail AD8 is mounted in LT00, the pins on LTC1 are used for NEAXmail AD8...
Page 72
CHAPTER 3 NDA-24219 Page 58 Revision 2.0 NAP-200-007 Sheet 9/55 Termination of Cables on MDF (1) C.O. Trunk (a) 4 Line C.O. Trunk (PN-4COT) (see Figure 007-4) Figure 007-4 MDF Cross Connection for 4 Line C.O. Trunk Card (PN-4COT) 29T3294 R3428 T2283 R2327 T12726 T026 2 1 1R0 26T0 2R1 27T1 3R2 28T2 4R3 29T3 (P) 26 T0 1 R0 27 T1 2 R1 28 T2 3 R2 29 T3 4 R3LEN0000 LEN0001 LEN0002 LEN0003 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) LEN0001 (No. 1) LEN0002 (No. 2) LEN0003 (No. 3) TO C.O. LINE TO...
Page 73
NDA-24219 CHAPTER 3 Page 59 Revision 2.0 NAP-200-007 Sheet 10/55 Termination of Cables on MDF (b) 8 Line C.O. Trunk (PN-8COT) (see Figure 007-5) Figure 007-5 MDF Cross Connection for 8 Line C.O. Trunk Card (PN-8COT) 33T7338 R7832 T6327 R6727 T12726 T026 2 1 1R026T0 2R127T1 7R632T6 8R733T7 (P) 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7LEN0000 LEN0001 LEN0006 LEN0007 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-8COT LT01LTC0 J LEN0001 (No. 1) LEN0006 (No. 6) LEN0007 (No. 7) TO C.O. LINE •...
Page 74
CHAPTER 3 NDA-24219 Page 60 Revision 2.0 NAP-200-007 Sheet 11/55 Termination of Cables on MDF (2) Tie Line Trunk (a) 4W E&M Trunk (PN-2ODT) (see Figure 007-6) Figure 007-6 MDF Cross Connection for 4W E&M Trunk Card (PN-2ODT) 1 26 2 27 3 28 4 29TxR0 TxT0 RcvR0 RcvT0 TxR1 TxT1 RcvR1 RcvT1MDF LEN0001 (No. 1) LEN0000 (No. 0)PIM0 PN-2ODT LT01 LEN0001 (No. 1) 1 26 2 27 3 28 4 29 (Rcv Tip) (Rcv Ring) (M) TO TIE LINE JPLTC0 LEN0000 (No. 0) 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Tx Tip)...
Page 75
NDA-24219 CHAPTER 3 Page 61 Revision 2.0 NAP-200-007 Sheet 12/55 Termination of Cables on MDF Figure 007-6 MDF Cross Connection for 4W E&M Trunk Card (PN-2ODT) (Continued) M1 E1 M0 E0LEN0001 LEN0000 CN1 1 LTC CONNECTOR2 CN1 CONNECTOR (FRONT CONNECTOR) LEN0000 LEN00011 TxR0 26 TxT0 2 RcvR0 27 RcvT0 3 TxR1 28 TxT1 4 RcvR1 29 RcvT1 (P) 26 TxT0 1 TxR0 27 RcvT0 2 RcvR0 28 TxT1 3 TxR1 29 RcvT1 4 RcvR1 LTC0 (J)
Page 76
CHAPTER 3 NDA-24219 Page 62 Revision 2.0 NAP-200-007 Sheet 13/55 Termination of Cables on MDF (b) 2W E&M (PN-2ODT) (see Figure 007-7) Figure 007-7 MDF Cross Connection for 2W E&M Trunk Card (PN-2ODT) 1 26 2 27 3 28 4 29 TO-10 TO-9 R0 T0 R1 T1 R2 T2 R3 T3MDF LEN0001 (No. 1) LEN0000 (No. 0)PIM0 PN-2ODT LT01 LEN0001 (No. 1) 1 26 2 27 3 28 4 29 (M) TO TIE LINE JPLTC0 LEN0000 (No. 0) CN1 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Ring) (Tip) J INSTALLATION CABLE Note 1:Both No. 0 and No. 1...
Page 77
NDA-24219 CHAPTER 3 Page 63 Revision 2.0 NAP-200-007 Sheet 14/55 Termination of Cables on MDF Figure 007-7 MDF Cross Connection for 2W E&M Trunk Card (PN-2ODT) (Continued) M1 E1 M0 E0LEN0001 LEN0000 CN1 1 LTC CONNECTOR2 CN1 CONNECTOR (FRONT CONNECTOR) LEN0000 LEN00011R026T0 227 3R228T2 429 (P) 26 T0 1 R0 27 2 28 T2 3 R2 29 4 LTC0 (J)
Page 78
CHAPTER 3 NDA-24219 Page 64 Revision 2.0 NAP-200-007 Sheet 15/55 Termination of Cables on MDF (3) DID Trunk (a) 2 Line DID Trunk (PN-AUCA) (see Figure 007-8) Figure 007-8 MDF Cross Connection for 2 Line DID Trunk Card (PN-AUCA) 29294 428 283 327 2726 26 2 1 LEN0000 LEN0001MDF 1 2 PIM0 P PN-AUCA LT01LTC0 J T1 R1 T0 R0 LEN0000 (No. 0) LEN0001 (No. 1) TO DID LINE 1R026T0 2R127T1 328 429 (P) 26 T0 1 R0 27 T1 2 R1 28 3 29 4 LTC0 (J) TO DID LINE Note:The PN-AUCA card can also be used as a long line...
Page 79
NDA-24219 CHAPTER 3 Page 65 Revision 2.0 NAP-200-007 Sheet 16/55 Termination of Cables on MDF (b) 4 Line DID Trunk (PN-4DITB) (see Figure 007-9) Figure 007-9 MDF Cross Connection for 4 Line DID Trunk Card (PN-4DITB) 29T3294 R3428 T2283 R2327 T12726 T026 2 1 1R026T0 2R127T1 3R228T2 4R329T3 (P) 26 T0 1 R0 27 T1 2 R1 28 T2 3 R2 29 T3 4 R3LEN0000 LEN0001 LEN0002 LEN0003 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) LEN0001 (No. 1) LEN0002 (No. 2) LEN0003 (No. 3) TO DID LINE TO DID LINE TO DID...
Page 80
CHAPTER 3 NDA-24219 Page 66 Revision 2.0 NAP-200-007 Sheet 17/55 Termination of Cables on MDF (4) Single Line Telephone (a) Standard Line (PN-8LC) (see Figure 007-10) Figure 007-10 MDF Cross Connection for Single Line Telephone (Standard Line) 33T7338 R7832 T6327 R6727 T12726 T026 2 1 1R026T0 2R127T1 7R632T6 8R733T7 (P) 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7LEN0000 LEN0001 LEN0006 LEN0007 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-8LC LT01LTC0 J LEN0001 (No. 1) LEN0006 (No. 6)...