Page 61
NDA-24219 CHAPTER 3 Page 47 Revision 2.0 NAP-200-005 Sheet 4/4 Connection of Battery (2) Plug the battery cable connector into the BATT1 connector on the PZ-PW86/PZ-PW112 as shown in Fig- ure 005-3. (3) Secure the batteries and battery cable using tie wraps. Figure 005-3 Internal Battery Connection PLUG IN TO BATT 1 CONNECTOR ON PZ-PW86 FRONT TIE WRAP BASEPIM
Page 62
CHAPTER 3 NDA-24219 Page 48 Revision 2.0 NAP-200-006 Sheet 1/2 Cable Running to MDF 1. MDF CABLE To facilitate the termination of the 25 pair cables (MDF cables) from the system to the MDF, the length of each cable to be used should be predetermined according to the distance between the MDF and the system. Each cable should be labeled at both ends using a cable number or cable designation as shown in Figure 006-1. Figure 006-1 MDF Cable FROM CABLE NUMBERTOCABLE DESTINATION MODULE CONNECTION PIM0LT C 0...
Page 63
NDA-24219 CHAPTER 3 Pag e 49 Revision 2.0 NAP-200-006 Sheet 2/2 Cable Running to MDF 2. CABLE RUNNING TO EXTERNAL MDF (1) Bring the MDF cable up to the Main Equipment through the cable hole(s) of the bottom cover. (2) Connect the champ connector of each MDF cable to an LTC connector located on a PIM using the screws provided, as shown in Figure 006-2. (3) Pare the sheath of each MDF cable and secure the shield to the bottom of the PIM using tie wraps, as shown in Figure 006-2. Figure 006-2 Cable...
Page 64
CHAPTER 3 NDA-24219 Page 50 Revision 2.0 NAP-200-007 Sheet 1/55 Termination of Cables on MDF 1. CABLE CONNECTION TO MDF (1) Connect the cables to the MDF referring to Figure 007-1 and Table 007-1. Figure 007-1 Card Slots and LTC Connectors Location Table 007-1 LTC Connector Accommodation LTC CONNECTOR CARD SLOT NUMBER REMARKS LT C 0 LT 0 1 ~ LT 0 3 LT C 1LT04/AP0 ~ LT08/AP4 When AD8 is mounted in LT00, pins 25 and 50, bring out leads for AD8 internal modem connection. 00 LT01 LT02 LT03 LT04 LT /...
Page 65
NDA-24219 CHAPTER 3 Page 51 Revision 2.0 NAP-200-007 Sheet 2/55 Termination of Cables on MDF (2)Figure 007-2 shows the relationship between each Line Equipment Number (LEN) and each Card Slot Number (LT Number). Figure 007-2 Location of Each LEN Note 1:Do not mount line/trunk circuit card with cabling in this slot; this slot has no connection to the MDF via the backplane (LTC cables). Note 2:When an 8-port line/trunk card, which requires cabling to MDF, is mounted in Slot 04, Slot 05 must be left...
Page 66
CHAPTER 3 NDA-24219 Page 52 Revision 2.0 NAP-200-007 Sheet 3/55 Termination of Cables on MDF (3)Figure 007-3 shows the LTC connector pin arrangement. Figure 007-3 LTC Connector Pin Arrangement LTC0 26 1 LEN0000 LT01 27 2 0001 28 3 0002 29 4 0003 30 5 0004 31 6 0005 32 7 0006 33 8 0007 34 9 0008 LT02 35 10 0009 36 11 0010 37 12 0011 38 13 0012 39 14 0013 40 15 0014 41 16 0015 42 17 0016 LT03 43 18 0017 44 19 0018 45 20 0019 46 21 0020 47 22 0021 48 23 0022 49 24 LEN0023 50 MN 25 MJLTC1 26 1 LEN0024...
Page 67
NDA-24219 CHAPTER 3 Page 53 Revision 2.0 NAP-200-007 Sheet 4/55 Termination of Cables on MDF Figure 007-3 LTC Connector Pin Arrangement (Continued) LTC0 26 1 LEN0064 LT01 27 2 0065 28 3 0066 29 4 0067 30 5 0068 31 6 0069 32 7 0070 33 8 0071 34 9 0072 LT02 35 10 0073 36 11 0074 37 12 0075 38 13 0076 39 14 0077 40 15 0078 41 16 0079 42 17 0080 LT03 43 18 0081 44 19 0082 45 20 0083 46 21 0084 47 22 0085 48 23 0086 49 24 LEN0087 50 25LTC1 26 1 LEN0088 LT04/AP0/LT05/AP1 27 2 0089 28 3 0090 29 4 0091 30 5...
Page 69
NDA-24219 CHAPTER 3 Page 55 Revision 2.0 NAP-200-007 Sheet 6/55 Termination of Cables on MDF * Major and minor alarm connections are used for external indications. Note 1:When an 8-port card is mounted in LT04 or LT06, LT05 or LT07 must be left vacant or mounted with circuit card, which do not interfere with the 8-port cards. Note 2:When NEAXmail AD8 is mounted in LT00, the pins on LTC1 are used for NEAXmail AD8 internal modem connection.Table 007-2 LTC0 and LTC1 MDF Cross Connection Information...
Page 70
CHAPTER 3 NDA-24219 Page 56 Revision 2.0 NAP-200-007 Sheet 7/55 Termination of Cables on MDF Note 1:When LT04 or LT06 is mounted with an 8-port card, LT05 and/or LT07 must be vacant or mounted with a noninter- facing card. Note 2:2 wire type for Multiline Terminal/DSS Console/DESKCON. Note 3:4 wire type for Multiline Terminal/SN610 ATTCON.Table 007-2 LTC0 and LTC1 MDF Cross Connection Information (Continued) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE Multiline Terminal (8DLC) Note 2Multiline...