Page 21
NDA-24219 CHAPTER 2 Page 7 Revision 2.0 Figure 2-4 19-Inch Rack-Mounting Installation PIM 19”BRACKET (H)
Page 23
NDA-24219 CHAPTER 2 Page 9 Revision 2.0 3. FUNCTIONAL OUTLINE OF EQUIPMENT This section explains the functional outline of the equipment (modules, installation hardware, circuit cards) used in the PBX. 3.1 Functional Outline of Modules Table 2-2 shows the functional outline of the modules. 3.2 Functional Outline of Installation Hardware Table 2-3 shows the functional outline of installation hardware. Table 2-2 Functional Outline of Modules MODULESFUNCTIONAL NAMEFUNCTIONAL OUTLINE SN1420 PIMAB-A PIM...
Page 24
CHAPTER 2 NDA-24219 Page 10 Revision 2.0 3.3 Functional Outline of Circuit Cards 3.3.1 Control Circuit Card Table 2-4 shows the functional outline of each control circuit cards. Table 2-4 Functional Outline of Control Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE PN-CP03 MP Main Processor Card This card is equipped with Memory, TDSW (1024CH ´ 1024CH), 16-Line CFT, DTMF Sender, Clock, PLO (receiver mode 2 ports), RS-232C Ports (2 ports) for MAT/Built-in SMDR, modem for remote maintenance,...
Page 25
NDA-24219 CHAPTER 2 Page 11 Revision 2.0 3.3.2 Application Circuit Cards Table 2-5 shows the functional outline of each application circuit card. Table 2-5 Functional Outline of Application Circuit Cards CARD NAMEFUNCTIONAL NAMEFUNCTIONAL OUTLINE SPN-AP00-A AP00 Application Processor Card This card is equipped with four RS-232C ports, and is used for SMDR, H/M Printer, PMS functions and MCI. This card is used on the basis of one per system. SPN-AP01 AP01 Application Processor Card This card is...
Page 26
CHAPTER 2 NDA-24219 Page 12 Revision 2.0 3.3.3 Line/Trunk Circuit Cards Table 2-6 shows the functional outline of each line/trunk circuit card. SPN-DAIA DAIA Firmware Processor Bus Card—With T1 Used in main system when connecting to Remote PIM SPN-DAIB. SPN-4RSTB- 911MF-911 Provides MF signaling for Enhanced 911. SPN-SC03 CSH Channel Handler for Zone Transceivers SPN-SC03 ICH ISDN-BRI Channel Handler Provides D-channel signaling interface for four ILCA cards. Table 2-6 Functional Outline of Line/Trunk...
Page 27
NDA-24219 CHAPTER 2 Page 13 Revision 2.0 PN-4DITB DIT 4-line Direct In-Dialing Trunk Card This card is equipped with the function for loop detection, sending reverse signal and PB to DP signal conversion. This card is internally equipped with –48 V DC On-Board Power supply. PN-DK00 DK Circuit card for External Relay Control/External Key Scan This card is provided with eight circuits, and can provide the above-mentioned control functions on a per circuit basis. PN-4DLCA/ PN-4DLCMDLC 4-line Digital...
Page 28
CHAPTER 2 NDA-24219 Page 14 Revision 2.0 PN-8LCS LC 8-line Analog Line Circuit Card for single-line telephones Loop resistance: Max. 600 W This card is equipped with a controller for momentary open function. PN-M03 M03 V.35 DTE Interface Card This card is used together with the PN-2DPCB card to provide the V.35 interface. PN-2ODTA ODT 2-line OD Trunk Card This card can be used as either a 2-wire E&M trunk or a 4-wire E&M trunk, and is internally equipped with a –48 V DC On-Board Power Supply. Both No....
Page 29
NDA-24219 CHAPTER 2 Page 15 Revision 2.0 DTP-16-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-16D-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB / 2DLCN (LONG)2788ft. (850m) [3937ft. (1200m)] DTP-32-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m)Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB...
Page 30
CHAPTER 2 NDA-24219 Page 16 Revision 2.0 * The value in the [ ] shows the cable length when using the long line function. Note 1:When using PN-8DLCJ or PN-8DLCP card, it is not available long line function. Note 2:The DSS/BLF Console requires local AC/DC power supply. Note 3:With AC/DC power at DESKCON 3000’ with 4DLCD ETJ-16DD-1 PN-8DLCJ / 8DLCP (STANDARD)656ft. (200m) Note 1 PN-4DLCD / 4DLCQ (STANDARD)656ft. (200m) [3937ft. (1200m)] PN-2DLCB (LONG)2788ft. (850m) [3937ft. (1200m)] ETJ-24DS-1 PN-8DLCJ...