NEC Neax 1000 Ivs Very Small Platform System Manual
Here you can view all the pages of manual NEC Neax 1000 Ivs Very Small Platform System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 51
NDA-24219 CHAPTER 3 NAP-2 00-003 PZ-PW86 (C) PW R CNT C A-A/ FRAME G ROUND TERMINAL ON THE CHASSIS C A UTION :Set the app ropri ate voltage be fo re Note 1 :Follow the Labe l on the f ront plate of the PZ-PW86. B ATTE RY CONNEC TO R (B ATT1) 1Note 1 1 :NO CONNECTI ON
Page 52
CHAPTER 3 NDA-24219 Page 38 Revision 2.0 NAP-200-003 Sheet 9/12 Installation of Main Equipment Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued) PZ-PW86(D) MJ MN ON BATTERY MODE SWITCH GND Note 2 FG –27V PWR CNT CA-A/ TO PWR1 AC CORD-A TO AC MAINS INPUT TO TO PWR0A CONNECTOR POWER OUTPUT CONNECTOR TO AUXILIARY BATTERY CONNECTOR (BATT2) ON OFF 100/120V 240V EQUIPMENT GREEN WHITE BLACK FRAME GROUND Note 1: Follow the Label on Front Plate of PZ-PW86(D). Note 2: If GND (Signal GND) has to be...
Page 53
NDA-24219 CHAPTER 3 Page 39 Revision 2.0 NAP-200-003 Sheet 10/12 Installation of Main Equipment Figure 003-7 Cable Connection on PZ-PW86/PW112 (Continued) PZ-PW112 MJ MN ON GND Note FG –27V PWR CNT CA-A/ TO PWR1 AC CORD-A TO AC MAINS INPUT TO CONNECTOR TO AUXILIARY BATTERY CONNECTOR (BATT2) ON OFF EQUIPMENT GREEN WHITE BLACK FRAME GROUND Note: If GND (Signal GND) has to be separated from FG (Frame GND), remove the link between GND and FG terminal – O TERMINAL ON THE TO OTHER PZ-PW112 PWR CA-A TO...
Page 54
CHAPTER 3 NDA-24219 NAP-200-003 LTC CONNECTOR AREA PI M1 PWR0C PWR C NT CA -C LTC CON NECTOR AREA PIM0 PWR0C P WR CNT CA-C
Page 55
NDA-24219 CHAPTER 3 Page 41 Revision 2.0 NAP-200-003 Sheet 12/12 Installation of Main Equipment (3) Bring the AC CORD-A-U out of the PIM through the cable hole on the bottom of the lower PIM, and plug it into a commercial AC outlet. Figure 003-9 AC Power Cable Wiring AC CORD-A-U TO FGTERMINAL
Page 56
CHAPTER 3 NDA-24219 NAP-200-004 PIM1 Note : For details of battery connectio n, see NAP- 200-00 4. P WR C A-A PIM1 P WR C A-A TO B ATT ER Y TO B ATT ER Y
Page 57
NDA-24219 CHAPTER 3 Page 43 Revision 2.0 NAP-200-004 Sheet 2/2 PWR CA-A and BUS Cable Connection (2) Mount the BS00 Card in the BUS slot of PIM0. Also, mount the BS01 Card in the BUS slot of PIM1. When the system is a single PIM configuration, neither PN-BS00 nor PN-BS01 is needed. (3) Connect the BUS cards using BUS cable (48-TW-0.7 CONN CA). Figure 004-2 Mounting BUS Cards PIM1 PIM0BS01 CN2 CN1 BS00 CN2 CN1 48-TW-0.7 CONN CA
Page 58
CHAPTER 3 NDA-24219 Page 44 Revision 2.0 NAP-200-005 Sheet 1/4 Connection of Battery 1. BATTERY CONNECTION CAUTION 1:24V batteries must be used in this system. CAUTION 2:If battery terminals (+, –) contact with the module under connecting the battery cable to the PZ- PW86/PW112 card, the PZ-PW86/PW112 card or the BWB may be broken. Therefore, the in- staller must perform work in accordance with the following steps when mounting or removing the batteries. • When mounting batteries: (1) Connect the...
Page 59
NDA-24219 CHAPTER 3 Page 45 Revision 2.0 NAP-200-005 Sheet 2/4 Connection of Battery CAUTION 3: Battery Replacement Table and Battery Warnings The label, which shows battery replacement table and battery warnings, is attached to the re- verse side of Front Cover for PIM. During the battery installation process, always observe the warning statements. When replacing batteries, adhere to the battery replacement table to in- crease battery life and to insure safe operation. See Figure 005-1. Figure 005-1...
Page 60
CHAPTER 3 NDA-24219 Page 46 Revision 2.0 NAP-200-005 Sheet 3/4 Connection of Battery 1.1 Internal Battery Connection (1) Mount the battery unit (24V DC, 2.6 AH) into the PIM (standard with system) as shown in Figure 005-2. Figure 005-2 Internal Battery Mounting FRONT 34mmDIMENSION OF BATTERY BATTERY UNIT (2´ 12V DC, 2.6 AH) (STANDARD) (1.3 inches) 178mm (7 inches) 60mm (2.4 inches) PIM Red Blue Black +–+ –