Page 121
NDA-24219 CHAPTER 3 Page 107 Revision 2.0 NAP-200-008 Sheet 3/10 Switch Setting of Circuit Card (3) Switch Setting (see Table 008-4) Table 008-4 PN-CP03 (MP) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary SW) 0 - FOn Line (Call processing is in progress) 2Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3Off Line (Call processing is stopped) • I/O port: 1200bps (Fixed) B For clearing office data C For setting resident system program 1,...
Page 122
CHAPTER 3 NDA-24219 Page 108 Revision 2.0 NAP-200-008 Sheet 4/10 Switch Setting of Circuit Card The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note:Set the groove on the switch knob to the desired switch position.Table 008-4 PN-CP03 (MP) Card Switch Settings (Continued) SWITCH NAMESWITCH...
Page 123
NDA-24219 CHAPTER 3 Page 109 Revision 2.0 NAP-200-008 Sheet 5/10 Switch Setting of Circuit Card CAUTION: When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. 3. PZ-PW86 (PWR) (1) Locations of Lamps, Switches, and Connectors (see Figure 008-2) Figure 008-2 PZ-PW86 (PWR) Card FRONT VIEW BATT2 MN MJ ONBATTERY SIDE VIEW GND –27V FG OFFON 240VAC 100/120VAC 2ON 2 1 ON SW301 START SIG 1 SW1 BATT1 AC INPUTMODE SW102 • PZ-PW86(C) AT T...
Page 124
CHAPTER 3 NDA-24219 Page 110 Revision 2.0 NAP-200-008 Sheet 6/10 Switch Setting of Circuit Card Figure 008-2 PZ-PW86 (PWR) Card (Continued) (2) Lamp Indications (see Table 008-5) Table 008-5 PZ-PW86 (PWR) Card Lamp Indications LAMP NAME COLOR FUNCTION MJ Red Lights upon occurrence of a major fault. MN Yellow Lights upon occurrence of a minor fault. ON Green Remains lit while the power is on. FRONT VIEWBATT2 MN MJ ON BATTERY SIDE VIEW GND –27V FG OFFON 240VAC 100/120VAC2ON 2 1 ON SW102 START SIG 1 SW1...
Page 125
NDA-24219 CHAPTER 3 Page 111 Revision 2.0 NAP-200-008 Sheet 7/10 Switch Setting of Circuit Card (3) Switch Settings (see Table 008-6) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Table 008-6 PZ-PW86 (PWR) Card Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK Mode (Piano Key...
Page 129
NDA-24219 CHAPTER 3 Page 115 Revision 2.0 NAP-200-009 Sheet 1/3 Mounting Circuit Cards 1. MOUNTING PROCEDURE (1) For testing, turn on “SW1” switch on the PZ-PW86/PZ-PW112 card. Make sure that “ON” lamp (green) is lit. See Figure 009-1. (2) Turn off “SW1” switch. Figure 009-1 PZ-PW86/PZ/PW112 Card Lamp Indication PZ-PW86/PW112 ON OFFSW SWITCH ON LAMP (GREEN)MN MJ ON
Page 130
CHAPTER 3 NDA-24219 Page 116 Revision 2.0 NAP-200-009 Sheet 2/3 Mounting Circuit Cards (3) Before mounting the circuit cards, confirm the following items. • Wrist Strap is connected Frame Ground. • Switch setting of circuit cards is already completed (Refer to the Circuit Card Manual). • “SW1” switch of PZ-PW86PZ/PW112 Card is turned off. (4) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and “Port Assign- ment Table” given in the System Data Sheet. Figure 009-2...