NDA-24219 CHAPTER 3 Page 117 Revision 2.0 NAP-200-009 Sheet 3/3 Mounting Circuit Cards (5) Install the Card Stopper according to the following procedure: (a) Insert the left side of the Card Stopper to the slot for the Card Stopper as shown in Fig. of Figure 009-3. (b) Loosen the attached screw for the Card Stopper, and hang the right side of the Card Stopper onto the screw. Then, tighten the screw as shown in Fig. of Figure 009-3. Figure 009-3 Installing Card Stopper A B Fig. AFig. B Fig. B Fig....
Page 132
CHAPTER 3 NDA-24219 Page 118 Revision 2.0 NAP-200-010 Sheet 1/7 System Initialization and System Data Entry 1. SYSTEM INITIALIZATION • There are two methods for System Initialization. The first method is to Clear All Data, except LEN0000 as a CAT terminal, and then program the System Data. The second method is to use the Resident System Pro- gram, which causes the system to configure itself automatically to the default settings, wherever the line/ trunk cards are installed. Refer to the System Data...
Page 133
NDA-24219 CHAPTER 3 Page 119 Revision 2.0 NAP-200-010 Sheet 2/7 System Initialization and System Data Entry 2. SYSTEM DATA ENTRY • There are two methods for data entry, both of which employ a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). 2.1 CAT Any multiline terminal can be assigned as a CAT terminal through programming. The multiline terminal can still be used as a regular telephone when it is not in CAT mode. If the system is initialized by “C” (Resident...
Page 134
CHAPTER 3 NDA-24219 Page 120 Revision 2.0 NAP-200-010 Sheet 3/7 System Initialization and System Data Entry To reset CAT mode: While “COMMAND = -” is displayed on the LCD: (1) Lift the handset (off hook) - SPKR lamp turns off. (2) Restore the handset (on hook) - CNF, ANS lamps turn off. - LCD returns to clock. The 48-port Quick Install program allows the technician to set up the NEAX1000 IVS by completing a step-by-step guide to install and program stations, line keys, and selective features into the...
Page 135
NDA-24219 CHAPTER 3 Page 121 Revision 2.0 NAP-200-010 Sheet 4/7 System Initialization and System Data Entry (1) Programming Procedure for Music On Hold For providing Hold Tone Source on the MP card: For providing External Hold Tone Source through the MP card: DESCRIPTION DATA Select the music to be provided. (3) 183 (4) 0: Nocturne 1 : Minuet Define the type of call to be provided with Hold Tone on the MP card. Note:When using the MP card, set the JP1 switch to UP (Internal Hold Tone Source)..Y = 0...
Page 136
CHAPTER 3 NDA-24219 Page 122 Revision 2.0 NAP-200-010 Sheet 5/7 System Initialization and System Data Entry For providing External Hold Tone Source through MP card: • External Hold Tone Source provided locally For connecting the External Hold Tone Source, plug the cable into the MP card jack. See Figure 0010-1. Figure 0010-1 Connecting External Hold Tone Source Set the switches on the MP card as shown in Figure 0010-2. Figure 0010-2 MP Card Switch Setting Note:To set Hold Tone Source on the MP card,...
Page 137
NDA-24219 CHAPTER 3 Page 123 Revision 2.0 NAP-200-010 Sheet 6/7 System Initialization and System Data Entry (2) Programming Procedure for Pushbutton Calling DESCRIPTION DATA Assign the Card Number of internal PB Receiver to the LEN No. 0124. Note:When using the internal PB Receiver on the MP card, assign the Card No. E200- E203 to the LEN No. 0124. If resident load is used, PB Receiver ports (E200-LENS 0124) are automatically as- signed.(1) LEN: 0124 (2) E200-E203 (PB Receiver No.) Assign the type of...
Page 138
CHAPTER 3 NDA-24219 Page 124 Revision 2.0 NAP-200-010 Sheet 7/7 System Initialization and System Data Entry DESCRIPTION DATA Assign the type of signaling (DTMF) for Outgoing and Bothway Trunk Routes..YY = 01 (1) Trunk Route No. (00 - 63) (2) 7 Specify the DTMF Sender characteristics to match the distant office..YY = 24 (DTMF Inter Digital Pause) (1) Trunk Route No. (00 - 63) .YY = 26 (DTMF Sender Signal Width) (1) Trunk Route No. (00 - 63) (2) 0/1 : 64ms/128ms .YY = 46 (DTMF Sender Release Timing)...
Page 139
NDA-24219 CHAPTER 3 Page 125 Revision 2.0 NAP-200-011 Sheet 1/1 Operation Test 1. OPERATION TEST Confirm the entered system data and hardware, including cable connection, by completing the following operational tests. • Basic Connection Test at MDF - Station Line Test (Operator Call from all stations) - Central Office Trunk Test (Incoming, Outgoing) - Tie Line Trunk Test (Incoming, Outgoing) • Service Feature Test - Call Transfer -Step Call - Executive Right of Way - Call Hold - Call Back - Call...
Page 140
CHAPTER 3 NDA-24219 Page 126 Revision 2.0 NAP-200-012 Sheet 1/1 Cleaning and Visual Check 1. CLEANING Clean the following places: • Inside of the main equipment, especially the bottom of the base. •On the Top Cover. • Around the Main Equipment and the MDF. • Keyboard on the Attendant Console. 2. VISUAL CHECK (1) Check to see if all circuit cards are in their positions correctly. (2) Check that the cable connections in the PIM are correctly and completely connected, and the routing of the cables has...